The novel magnesium-titanium hybrid cannulated screws for the treatment of vertical femoral neck fractures: Biomechanical evaluation

被引:6
|
作者
Zhang, Qida [1 ,6 ]
Chen, Zhenxian [2 ]
Peng, Yinghu [3 ]
Jin, Zhongmin [4 ,5 ]
Qin, Ling [1 ,6 ]
机构
[1] Chinese Univ Hong Kong, Dept Orthopaed & Traumatol, Musculoskeletal Res Lab, Hong Kong, Peoples R China
[2] Changan Univ, Sch Mech Engn, Key Lab Rd Construction Technol & Equipment, Minist Educ, Xian, Peoples R China
[3] Chinese Acad Sci, Shenzhen Inst Adv Technol, CAS Key Lab Human Machine Intelligence Synergy Sys, Shenzhen, Peoples R China
[4] Southwest Jiaotong Univ, Tribol Res Inst, Sch Mech Engn, Chengdu, Peoples R China
[5] Univ Leeds, Inst Med & Biol Engn, Sch Mech Engn, Leeds, England
[6] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Orthopaed & Traumatol, Musculoskeletal Res Lab,Shatin, 30-32 Ngan Shing St, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Biomechanics; Cannulated screws; Finite element analysis; Musculoskeletal multibody model; Vertical femoral neck fractures; MECHANICAL-PROPERTIES; INTERNAL-FIXATION; TRABECULAR BONE; PREDICTION; DENSITY; LOAD; TRANSLATION; FORCE;
D O I
10.1016/j.jot.2023.08.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Conventional cannulated screws are commonly used for internal fixation in the treatment of vertical femoral neck fractures. However, the noticeably high rates of undesirable outcomes such as nonunion, malunion, avascular necrosis, and fixation failure still troubled the patients and surgeons. It is urgent to develop new cannulated screws to improve the above clinical problems. The purpose of this study was to design a novel magnesium-titanium hybrid cannulated screw and to further evaluate its biomechanical performance for the treatment of vertical femoral neck fractures. Methods: A novel magnesium-titanium hybrid cannulated screw was designed, and the conventional titanium cannulated screw was also modeled. The finite element models for vertical femoral neck fractures with magnesium-titanium hybrid cannulated screws and conventional cannulated screws were respectively established. The hip joint contact force during walking gait calculated by a subject-specific musculoskeletal multibody dynamics model, was used as loads and boundary conditions for both finite element models. The stress and displacement distributions of the cannulated screws and the femur, the micromotion of the fracture surfaces of the femoral neck, and the overall stiffness were calculated and analyzed using finite element models. The biomechanical performance of the Magnesium-Titanium hybrid cannulated screws was evaluated. Results: The maximum stresses of the magnesium-titanium hybrid cannulated screws and the conventional cannulated screws were 451.5 MPa and 476.8 MPa, respectively. The maximum stresses of the femur with the above different cannulated screws were 140.3 MPa and 164.8 MPa, respectively. The maximum displacement of the femur with the hybrid cannulated screws was 6.260 mm, lower than the femur with the conventional cannulated screws, which was 7.125 mm. The tangential micromotions in the two orthogonal directions at the fracture surface of the femoral neck with the magnesium-titanium hybrid cannulated screws were comparable to those with the conventional cannulated screws. The overall stiffness of the magnesium-titanium hybrid cannulated screw system was 490.17 N/mm, higher than that of the conventional cannulated screw system, which was 433.92 N/mm. Conclusion: The magnesium-titanium hybrid cannulated screw had superior mechanical strength and fixation stability for the treatment of the vertical femoral neck fractures, compared with those of the conventional cannulated screw, indicating that the magnesium-titanium hybrid cannulated screw has great potential as a new fixation strategy in future clinical applications. The translational potential of this article: This study highlights an innovative design of the magnesium-titanium hybrid cannulated screw for the treatment of vertical femoral neck fractures. The novel magnesium-titanium
引用
收藏
页码:127 / 136
页数:10
相关论文
共 50 条
  • [41] Vertical shear fractures of the femoral neck - A biomechanical study
    Baitner, AC
    Maurer, SG
    Hickey, DG
    Jazrawi, LM
    Kummer, FJ
    Jamal, J
    Goldman, S
    Koval, KJ
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (367) : 300 - 305
  • [42] Biomechanical analysis of a novel femoral neck locking plate for treatment of vertical shear Pauwel's type C femoral neck fractures
    Nowotarski, Peter J.
    Ervin, Bain
    Weatherby, Brian
    Pettit, Jonathan
    Goulet, Ron
    Norris, Brent
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (06): : 802 - 806
  • [43] A Comparative Biomechanical Analysis of Fixation Devices for Unstable Femoral Neck Fractures: The Intertan Versus Cannulated Screws or a Dynamic Hip Screw
    Rupprecht, Martin
    Grossterlinden, Lars
    Ruecker, Andreas H.
    de Oliveira, Alexander Novo
    Sellenschloh, Kay
    Nuechtern, Jakob
    Pueschel, Klaus
    Morlock, Michael
    Rueger, Johannes Maria
    Lehmann, Wolfgang
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 71 (03): : 625 - 634
  • [44] Cannulated screws versus hemiarthroplasty for displaced intracapsular femoral neck fractures in demented patients
    van Dortmont, LMC
    Douw, CM
    van Breukelen, AMA
    Laurens, DR
    Mulder, PGH
    Wereldsma, JCJ
    van Vugt, AB
    ANNALES CHIRURGIAE ET GYNAECOLOGIAE, 2000, 89 (02) : 132 - 137
  • [45] Biomechanical evaluation of compression buttress screw and medial plate fixation for the treatment of vertical femoral neck fractures
    Fan, Zhi-Yuan
    Shu, Lin -Yuan
    Jin, Ying-Zhe
    Sherrier, Matthew C.
    Yin, Bo-Hao
    Liu, Chen -Jun
    Zhan, Shi
    Sun, Hui
    Zhang, Wei
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (12): : 3887 - 3893
  • [46] Optimum Configuration of Cannulated Compression Screws for the Fixation of Unstable Femoral Neck Fractures: Finite Element Analysis Evaluation
    Li, Jiantao
    Wang, Menglin
    Zhou, Jianfeng
    Han, Lin
    Zhang, Hao
    Li, Chen
    Li, Lianting
    Hao, Ming
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [47] Quick and Accurate Placement of Cannulated Screws to Internal Fixation of Femoral Neck Fractures Using a Novel Guide Device
    Ren, Bu-fang
    Li, Gang
    Ma, Quan-ping
    Lv, Xin
    Sun, Jian
    ADVANCES IN THERAPY, 2023, 40 (03) : 844 - 852
  • [48] Comparison Between Femoral Neck Systems and Cannulated Cancellous Screws in Treating Femoral Neck Fractures: A Meta-Analysis
    Tian, Peng
    Kuang, Lan
    Li, Zhi-jun
    Xu, Gui-jun
    Fu, Xin
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2022, 13
  • [49] Quick and Accurate Placement of Cannulated Screws to Internal Fixation of Femoral Neck Fractures Using a Novel Guide Device
    Bu-fang Ren
    Gang Li
    Quan-ping Ma
    Xin Lv
    Jian Sun
    Advances in Therapy, 2023, 40 : 844 - 852
  • [50] Modified cannulated screw fixation in the treatment of Pauwels type III femoral neck fractures: A biomechanical study
    Zhou, Lin
    Lin, Jiaming
    Huang, Anfei
    Gan, Weidong
    Zhai, Xu
    Sun, Kai
    Huang, Shiqing
    Li, Zhizhong
    CLINICAL BIOMECHANICS, 2020, 74 : 103 - 110