Optimum Configuration of Cannulated Compression Screws for the Fixation of Unstable Femoral Neck Fractures: Finite Element Analysis Evaluation

被引:32
|
作者
Li, Jiantao [1 ]
Wang, Menglin [2 ]
Zhou, Jianfeng [3 ]
Han, Lin [4 ]
Zhang, Hao [1 ]
Li, Chen [5 ]
Li, Lianting [6 ]
Hao, Ming [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Orthopaed, 28 Fuxing Rd, Beijing 100853, Peoples R China
[2] Peking Univ, Hosp 3, Dept Otolaryngol Head & Neck Surg, Beijing 100191, Peoples R China
[3] Chinese Peoples Liberat Army Gen Hosp, Dept Emergency, 28 Fuxing Rd, Beijing 100853, Peoples R China
[4] Second Mil Med Univ, Grad Sch, Shanghai 200433, Peoples R China
[5] Tianjin Hosp, Dept Orthopaed, 406 Jiefang Rd, Tianjin 300211, Peoples R China
[6] Third Peoples Hosp Qingdao, Dept Orthopaed, 29 Yongping Rd, Qingdao 266041, Peoples R China
关键词
COMPOSITE FEMUR; REMOVAL; COMPLICATIONS; DEVICES; RISK;
D O I
10.1155/2018/1271762
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objectives. In the present study, we evaluated the mechanical outcome of different configurations of cannulated compression screws for the fixation of Pauwels type III femoral neck fracture and the stress distribution around the holes corresponding to fixation protocol after screws removal. Methods. The Pauwels type III of femoral neck fracture was created in 3-matic software and the models of cannulated compression screws were constructed using UG-NX software. Five fixation systems were assembled to the fracture models. Abaqus software was used to perform the process of finite element analysis. Values of stress distribution, maximum stress, model principal strains of proximal fragment, and stress distribution around the holes of femur model were recorded. Results. Stress of cannulated compression screws was intensely focused on the middle area of the screw near the fragment of each group. Inverted triangle model showed the highest peak stress on screws under different phases of load. Each screw dispersed some stresses, but at least one underwent the peak stress. Fracture model fixed by inverted triangle configuration showed the lowest volume of yielding strain in the proximal fragment. The area of higher stress around the holes was largest after triangle screws removal when compared with other four models. Conclusions. Our study indicated that different cannulated compression screws fixation configurations for the unstable femoral neck fractures showed the different mechanical efficiency. Inverted triangular configuration showed the mechanical advantage and being less likely to cutout. The fixation strategy of triangle configuration was least recommended if patients tended to remove the implants.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Biomechanical Research of Three Parallel Cannulated Compression Screws in Oblique Triangle Configuration for Fixation of Femoral Neck Unstable Fractures
    Zhang, Ru-Yi
    Zhang, Wu-Peng
    Yang, Guang-Min
    Wang, Dao-Feng
    Su, Peng
    Zhang, Yi
    Nie, Shao-Bo
    Li, Jia
    Zhao, Zhe
    Li, Jian-Tao
    Zhang, Li-Cheng
    Tang, Pei-Fu
    ORTHOPAEDIC SURGERY, 2024, 16 (04) : 953 - 964
  • [2] The Effect of Configuration of Rhombic Cannulated Screws on Internal Fixation of Femoral Neck Fractures
    Guo, Jialiang
    Dong, Weichong
    Yin, Yingchao
    Zhang, Ruipeng
    Hou, Zhiyong
    Zhang, Yingze
    ORTHOPEDICS, 2020, 43 (02) : E72 - E78
  • [3] Is stability of femoral neck fractures in the inverted triangle configuration related to the angle between the fracture line and the cannulated compression screws? A finite element analysis
    Niu, Zhipeng
    Wang, Qian
    Yuan, Baoming
    Cui, Yutao
    Ren, Guangkai
    Wu, Dankai
    Peng, Chuangang
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024,
  • [4] Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis
    Ding, Kai
    Yang, Weijie
    Zhu, Jian
    Cheng, Xiaodong
    Wang, Haicheng
    Hao, Du
    Song Yinuo
    Zhu, Yanbin
    Zhang, Yingze
    Chen, Wei
    Zhang, Qi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [5] Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis
    Kai Ding
    Weijie Yang
    Jian Zhu
    Xiaodong Cheng
    Haicheng Wang
    Du Hao
    Song Yinuo
    Yanbin Zhu
    Yingze Zhang
    Wei Chen
    Qi Zhang
    Journal of Orthopaedic Surgery and Research, 16
  • [6] Comparison of oblique triangular configuration and inverted equilateral triangular configuration of three cannulated screws in treating unstable femoral neck fracture: A finite element analysis
    Zhang, Ru-Yi
    Li, Jian-Tao
    Zhao, Jing-Xin
    Zhao, Zhe
    Zhang, Li-Cheng
    Yun, Cai
    Su, Xiu-Yun
    Tang, Pei-Fu
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (02): : 353 - 361
  • [7] Cannulated screws fixation as an alternative treatment of femoral neck osteoporotic fractures
    Ciesielczyk, B
    Tuchocka-Piotrowska, A
    ANNALS OF THE RHEUMATIC DISEASES, 2005, 64 : 516 - +
  • [8] Femoral neck system and cannulated compression screws in the treatment of non-anatomical reduction Pauwels type-III femoral neck fractures: A finite element analysis
    Zhong, Zhou
    Lan, Xuejun
    Xiang, Zhou
    Duan, Xin
    CLINICAL BIOMECHANICS, 2023, 108
  • [9] Internal fixation using fully threaded cannulated compression screws for fresh femoral neck fractures in adults
    Kai-xuan Yuan
    Fan Yang
    Kai Fu
    Dao-yu Zhu
    Chen-yi Jiang
    Dong-xu Jin
    Ze-hao Wang
    Xiao-yuan Peng
    You-Shui Gao
    Peng-bo Luo
    Journal of Orthopaedic Surgery and Research, 17
  • [10] Internal fixation using fully threaded cannulated compression screws for fresh femoral neck fractures in adults
    Yuan, Kai-xuan
    Yang, Fan
    Fu, Kai
    Zhu, Dao-yu
    Jiang, Chen-yi
    Jin, Dong-xu
    Wang, Ze-hao
    Peng, Xiao-yuan
    Gao, You-Shui
    Luo, Peng-bo
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)