Biomechanical analysis of a novel femoral neck locking plate for treatment of vertical shear Pauwel's type C femoral neck fractures

被引:65
|
作者
Nowotarski, Peter J. [1 ]
Ervin, Bain [1 ]
Weatherby, Brian [2 ,6 ]
Pettit, Jonathan [3 ]
Goulet, Ron [4 ]
Norris, Brent [5 ]
机构
[1] Univ Tennessee, Coll Med Chattanooga, Dept Orthopaed, Chattanooga, TN 37403 USA
[2] Univ Texas Hlth Sci Ctr, Coll Med Houston, Dept Orthopaed, Houston, TX 77025 USA
[3] Middle Tennessee Bone & Joint, Columbia, TN 38401 USA
[4] Univ Tennessee, Coll Engn & Comp Sci, EMCS, Dept 2452, Chattanooga, TN 37403 USA
[5] Orthopaed Trauma Serv Oklahoma, Tulsa, OK 74114 USA
[6] Foot & Ankle Steadman Hawkins Clin Carolinas, Greenville, SC 29615 USA
关键词
Hip; Plate; Biomechanical; Locking; Cyclic; FIXATION; FEMUR; AGES;
D O I
10.1016/j.injury.2011.09.012
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The purpose of this study is to determine the biomechanical stability of a novel prototype femoral neck locking plate (FNLP) for treatment of Pauwels type C femoral neck fractures compared with other current fixation methods. Methods: Forty femur sawbones were divided into groups and a vertical femoral neck fracture was made. Each group was repaired with one of the following: (CS) three parallel cancellous screws; (XCS) two cancellous lag screws into the head and one transverse lag screw into the calcar; and (FNLP) a novel FNLP with two 5.7 mm locking, one lag screw into the calcar and two screws into the shaft; and (AMBI) a two-hole, 1358 AMBI plate with a derotation screw. All groups were tested for change in axial stiffness over 20 000 cycles, and rotational stiffness was measured before and after cyclic testing. A maximum load to failure test was also conducted. Results were compared with one-way analysis of variance (ANOVA) and Fisher protected least significant difference (PLSD). Results: Results for axial stiffness show that AMBI, CS, XCS and FNLP are 2779.0, 2207.2, 3029.9 and 3210.7 N-m mm (1), respectively. Rotational rigidity results are 4.5, 4.1, 17.1 and 18.7 N-m mm (1). The average cyclic displacements were 0.75, 0.88, 0.80 and 0.65 mm, respectively. Destructive failure loads for AMBI, CS, XCS and FNLP were 2.3, 1.7, 1.6 and 1.9 kN, respectively. Conclusions: The results of this experiment show statistically significant increases in axial stiffness for the FNLP compared with three traditional fixation methods. The FNLP demonstrates increased mechanical stiffness and combines the desirable features of current fixation methods. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:802 / 806
页数:5
相关论文
共 50 条
  • [1] Biomechanical Analysis of Augmented Plate Fixation for the Treatment of Vertical Shear Femoral Neck Fractures
    Kunapuli, Sarat C.
    Schramski, Matthew J.
    Lee, Angela S.
    Popovich, John M., Jr.
    Cholewicki, Jacek
    Reeves, N. Peter
    Crichlow, Renn J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (03) : 144 - 150
  • [2] Vertical shear fractures of the femoral neck - A biomechanical study
    Baitner, AC
    Maurer, SG
    Hickey, DG
    Jazrawi, LM
    Kummer, FJ
    Jamal, J
    Goldman, S
    Koval, KJ
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (367) : 300 - 305
  • [3] Clinical and Biomechanical Effects of Femoral Neck Buttress Plate used for Vertical Femoral Neck Fractures
    Steffensmeier, Andrew
    Shah, Nihar
    Archdeacon, Michael
    Watson, David
    Sanders, Roy W.
    Sagi, Henry C.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (03): : 1137 - 1143
  • [4] Proximal Femoral Locking Plate With Cannulated Screws for the Treatment of Femoral Neck Fractures
    Lin, Dasheng
    Lian, Kejian
    Ding, Zhenqi
    Zhai, Wenliang
    Hong, Jiayuan
    ORTHOPEDICS, 2012, 35 (01) : E1 - E5
  • [5] Biomechanical comparison of locking femoral neck plate versus cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures
    Onder, Yilmaz
    Bulut, Tugrul
    Eroglu, Osman Nuri
    Ciklacandir, Samet
    Isler, Yalcin
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2024, 58 (06)
  • [6] Biomechanical evaluation of percutaneous compression plate and femoral neck system in Pauwels type III femoral neck fractures
    Xie, Xiaoping
    Bi, Songqi
    Song, Qingxu
    Zhang, Qiong
    Yan, Zhixing
    Zhou, Xiaoyang
    Yu, Tiecheng
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2024, 25 (01)
  • [7] Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures: a Finite Element Analysis
    Cha, Yonghan
    Park, Sunghoon
    Jung, Chang-Ho
    Kim, Jin-Woo
    Yoo, Jun-Il
    Kim, Jung-Taek
    Jeon, Yongho
    Han, Kyeong Jin
    CLINICS IN ORTHOPEDIC SURGERY, 2025, 17 (02) : 204 - 215
  • [8] Biomechanical evaluation of compression buttress screw and medial plate fixation for the treatment of vertical femoral neck fractures
    Fan, Zhi-Yuan
    Shu, Lin -Yuan
    Jin, Ying-Zhe
    Sherrier, Matthew C.
    Yin, Bo-Hao
    Liu, Chen -Jun
    Zhan, Shi
    Sun, Hui
    Zhang, Wei
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (12): : 3887 - 3893
  • [9] Augmentation by cerclage wire improves fixation of vertical shear femoral neck fractures-A biomechanical analysis
    Kuan, Fa-Chuan
    Yeh, Ming-Long
    Hong, Chih-Kai
    Chiang, Florence L.
    Jou, I-Ming
    Wang, Ping-Hui
    Su, Wei-Ren
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (10): : 2081 - 2086
  • [10] Biomechanical study of two alternative methods for the treatment of vertical femoral neck fractures - A finite element analysis
    Xia, Yutong
    Zhang, Wendong
    Hu, Hai
    Yan, Lianqi
    Zhan, Shi
    Wang, Jingcheng
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2021, 211