The novel magnesium-titanium hybrid cannulated screws for the treatment of vertical femoral neck fractures: Biomechanical evaluation

被引:6
|
作者
Zhang, Qida [1 ,6 ]
Chen, Zhenxian [2 ]
Peng, Yinghu [3 ]
Jin, Zhongmin [4 ,5 ]
Qin, Ling [1 ,6 ]
机构
[1] Chinese Univ Hong Kong, Dept Orthopaed & Traumatol, Musculoskeletal Res Lab, Hong Kong, Peoples R China
[2] Changan Univ, Sch Mech Engn, Key Lab Rd Construction Technol & Equipment, Minist Educ, Xian, Peoples R China
[3] Chinese Acad Sci, Shenzhen Inst Adv Technol, CAS Key Lab Human Machine Intelligence Synergy Sys, Shenzhen, Peoples R China
[4] Southwest Jiaotong Univ, Tribol Res Inst, Sch Mech Engn, Chengdu, Peoples R China
[5] Univ Leeds, Inst Med & Biol Engn, Sch Mech Engn, Leeds, England
[6] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Orthopaed & Traumatol, Musculoskeletal Res Lab,Shatin, 30-32 Ngan Shing St, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Biomechanics; Cannulated screws; Finite element analysis; Musculoskeletal multibody model; Vertical femoral neck fractures; MECHANICAL-PROPERTIES; INTERNAL-FIXATION; TRABECULAR BONE; PREDICTION; DENSITY; LOAD; TRANSLATION; FORCE;
D O I
10.1016/j.jot.2023.08.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Conventional cannulated screws are commonly used for internal fixation in the treatment of vertical femoral neck fractures. However, the noticeably high rates of undesirable outcomes such as nonunion, malunion, avascular necrosis, and fixation failure still troubled the patients and surgeons. It is urgent to develop new cannulated screws to improve the above clinical problems. The purpose of this study was to design a novel magnesium-titanium hybrid cannulated screw and to further evaluate its biomechanical performance for the treatment of vertical femoral neck fractures. Methods: A novel magnesium-titanium hybrid cannulated screw was designed, and the conventional titanium cannulated screw was also modeled. The finite element models for vertical femoral neck fractures with magnesium-titanium hybrid cannulated screws and conventional cannulated screws were respectively established. The hip joint contact force during walking gait calculated by a subject-specific musculoskeletal multibody dynamics model, was used as loads and boundary conditions for both finite element models. The stress and displacement distributions of the cannulated screws and the femur, the micromotion of the fracture surfaces of the femoral neck, and the overall stiffness were calculated and analyzed using finite element models. The biomechanical performance of the Magnesium-Titanium hybrid cannulated screws was evaluated. Results: The maximum stresses of the magnesium-titanium hybrid cannulated screws and the conventional cannulated screws were 451.5 MPa and 476.8 MPa, respectively. The maximum stresses of the femur with the above different cannulated screws were 140.3 MPa and 164.8 MPa, respectively. The maximum displacement of the femur with the hybrid cannulated screws was 6.260 mm, lower than the femur with the conventional cannulated screws, which was 7.125 mm. The tangential micromotions in the two orthogonal directions at the fracture surface of the femoral neck with the magnesium-titanium hybrid cannulated screws were comparable to those with the conventional cannulated screws. The overall stiffness of the magnesium-titanium hybrid cannulated screw system was 490.17 N/mm, higher than that of the conventional cannulated screw system, which was 433.92 N/mm. Conclusion: The magnesium-titanium hybrid cannulated screw had superior mechanical strength and fixation stability for the treatment of the vertical femoral neck fractures, compared with those of the conventional cannulated screw, indicating that the magnesium-titanium hybrid cannulated screw has great potential as a new fixation strategy in future clinical applications. The translational potential of this article: This study highlights an innovative design of the magnesium-titanium hybrid cannulated screw for the treatment of vertical femoral neck fractures. The novel magnesium-titanium
引用
收藏
页码:127 / 136
页数:10
相关论文
共 50 条
  • [21] What is the Fate of Undisplaced Femoral Neck Fractures Treated With Cannulated Screws?
    Slullitel, Pablo A.
    Latallade, Valentino
    Huespe, Ivan A.
    Lucero-Viviani, Nicolas
    Buttaro, Martin A.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (01): : 111 - 117
  • [22] A new configuration of cannulated screw fixation in the treatment of vertical femoral neck fractures
    Baokun Zhang
    Jingwen Liu
    Yi Zhu
    Wei Zhang
    International Orthopaedics, 2018, 42 : 1949 - 1955
  • [23] Biomechanical Evaluation of Cannulated Screw Optimization for Stabilization of Pauwels Type Femoral Neck Fractures
    Verim, Ozgur
    APPLIED SCIENCES-BASEL, 2024, 14 (07):
  • [24] Treatment of femoral neck fractures: sliding hip screw or cannulated screws? A meta-analysis
    Xia, Yutong
    Zhang, Wendong
    Zhang, Zhen
    Wang, Jingcheng
    Yan, Lianqi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [25] Treatment of femoral neck fractures: sliding hip screw or cannulated screws? A meta-analysis
    Yutong Xia
    Wendong Zhang
    Zhen Zhang
    Jingcheng Wang
    Lianqi Yan
    Journal of Orthopaedic Surgery and Research, 16
  • [26] Comparison of femoral neck system versus cannulated screws for treatment of femoral neck fractures: a systematic review and meta-analysis
    Jiang, Jiabao
    Chen, Jialei
    Xing, Fei
    Liu, Hao
    Xiang, Zhou
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [27] Comparison of femoral neck system versus cannulated screws for treatment of femoral neck fractures: a systematic review and meta-analysis
    Jiabao Jiang
    Jialei Chen
    Fei Xing
    Hao Liu
    Zhou Xiang
    BMC Musculoskeletal Disorders, 24
  • [28] Biomechanical Evaluation of the Modified Cannulated Screws Fixation of Unstable Femoral Neck Fracture with Comminuted Posteromedial Cortex
    Liu, Jingwen
    Zhang, Baokun
    Yin, Bohao
    Chen, Hongchi
    Sun, Hui
    Zhang, Wei
    BIOMED RESEARCH INTERNATIONAL, 2019, 2019
  • [29] Biomechanical analysis of a new cannulated screw for unstable femoral neck fractures
    Chen, Zhigang
    Chen, Feiyang
    Xu, Xinbao
    Li, Xin
    Cui, Haidong
    Zhang, Wen
    Jiang, Dong
    Zhang, Feixiang
    Chen, Yinbing
    Zhou, Shiran
    Lyu, Shujun
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [30] Biomechanical comparison of locking femoral neck plate versus cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures
    Onder, Yilmaz
    Bulut, Tugrul
    Eroglu, Osman Nuri
    Ciklacandir, Samet
    Isler, Yalcin
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2024, 58 (06)