Modified cannulated screw fixation in the treatment of Pauwels type III femoral neck fractures: A biomechanical study

被引:25
|
作者
Zhou, Lin [1 ,7 ]
Lin, Jiaming [2 ]
Huang, Anfei [3 ]
Gan, Weidong [3 ]
Zhai, Xu [4 ]
Sun, Kai [5 ]
Huang, Shiqing [6 ,7 ]
Li, Zhizhong [1 ,7 ]
机构
[1] Jinan Univ, Dept Orthoped, Affiliated Hosp 1, Guangzhou, Peoples R China
[2] Sun Yat Sen Univ, Collaborat Innovat Ctr Canc Med, Dept Musculoskeletal Oncol, State Key Lab Oncol South China,Canc Ctr, Guangzhou, Peoples R China
[3] Jinan Univ, Clin Med Coll 1, Guangzhou, Peoples R China
[4] 903rd Hosp PLA, Dept Orthoped, Hangzhou, Peoples R China
[5] Jiujiang Univ, Jiujiang Univ Hosp, Clin Med Coll, Jiujiang, Peoples R China
[6] Jinan Univ, Sch Mechan & Construct Engn, Guangzhou, Peoples R China
[7] Clin Biomech & Biomimet Mat Res Ctr, Guangzhou, Guangdong, Peoples R China
关键词
Femoral neck fracture; Cannulated screw; Biomechanics; FIXED-ANGLE DEVICES; YOUNG-ADULTS; COMPLICATIONS;
D O I
10.1016/j.clinbiomech.2020.02.016
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Achieving satisfactory internal fixation for patients with Pauwels type III femoral neck fractures has become a critical problem. The purpose of this study was to compare a common standard internal reduction and fixation method for femoral neck fractures to the modified fixation methods. Methods: A computed tomography scan of the femur was performed to make a Three-dimensional (3D) model, and a fracture line was simulated in the femoral neck. 3Dfinite element analysis was carried out for different insertion methods of cannulated tension screws. Six healthy femur specimens were harvested from three formalin-fixed cadavers, and Pauwels type III femoral neck fracture was artificially created in bilateral femurs. The right side was treated with the inverted triangle construct method and the left side by the modified screw fixation method. After fixation, uniaxial compression and maximum load experiments on the bilateral femoral necks were carried out using the non-contact full-field dynamic strain measurement system (VIC-3D) on a pressure testing machine. Findings: Both 3D finite element analysis and biomechanical study showed that the modified screw fixation method(group D) provided better anti-shearing and anti-rotation properties for Pauwels type III femoral neck fractures, and offered better interfragmentary compression. Therefore, this modified screw fixation method can offer patients a better option for treatment of Pauwels type III femoral neck fractures. Interpretation: Changing the placement of the anterosuperior screw in the inverted triangle construct as perpendicular to the fracture line has the advantages in anti-shearing, anti-rotation and increasing interfragmentary compression.
引用
收藏
页码:103 / 110
页数:8
相关论文
共 50 条
  • [1] Biomechanical Evaluation of Cannulated Screw Optimization for Stabilization of Pauwels Type Femoral Neck Fractures
    Verim, Ozgur
    APPLIED SCIENCES-BASEL, 2024, 14 (07):
  • [2] Biomechanical evaluation of the expansive cannulated screw for fixation of femoral neck fractures
    Zhang, Yang
    Tian, Li
    Yan, Yabo
    Sang, Hongxun
    Ma, Zhensheng
    Jie, Qiang
    Lei, Wei
    Wu, Zixiang
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (11): : 1372 - 1376
  • [3] Biomechanical Evaluation of the Femoral Neck System in Unstable Pauwels III Femoral Neck Fractures: A Comparison with the Dynamic Hip Screw and Cannulated Screws
    Stoffel, Karl
    Zderic, Ivan
    Gras, Florian
    Sommer, Christoph
    Eberli, Ursula
    Mueller, David
    Oswald, Martin
    Gueorguiev, Boyko
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (03) : 131 - 137
  • [4] Internal fixation system with the pyramid screw head for the treatment of Pauwels type III femoral neck fractures
    Wang, Songyuan
    Deng, Xuan
    Zhong, Hao
    Ma, Lei
    Wang, Xiyu
    Lou, Xinqi
    Fan, Xuanze
    Duan, Wangping
    Zhang, Kai
    Li, Pengcui
    Wei, Xiaochun
    Zhao, Yongwang
    Wang, Yanqin
    Wu, Xiaogang
    Xue, Yanru
    Chen, Weiyi
    ACTA MECHANICA SINICA, 2023, 39 (08)
  • [5] Treatment of Pauwels type III femoral neck fracture with medial femoral neck support screw: a biomechanical and clinical study
    Gao, Zhichao
    Wang, Mei
    Shen, Baojie
    Chu, Xiaodong
    Ruan, Di
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [6] Treatment of Pauwels type III femoral neck fracture with medial femoral neck support screw: a biomechanical and clinical study
    Zhichao Gao
    Mei Wang
    Baojie Shen
    Xiaodong Chu
    Di Ruan
    Scientific Reports, 11
  • [7] Biomechanical and clinical evaluation of interlocking hip screw in Pauwels III femoral neck fractures: A comparison with inverted triangle cannulated screws
    Zhang, Jian
    Jiang, Haozheng
    Dai, Wei
    Hersi, Salad Abdirahman
    Cheong, John Chun Tien Chui Wan
    Chu, Zhenchen
    Lou, Zhiyuan
    Zhang, Deqiang
    Liu, Changjian
    Tian, Kang
    Tang, Xin
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [8] Cannulated versus non-cannulated cancellous screw fixation for femoral neck fractures: a synthetic bone biomechanical study
    Mutlu, Harun
    Mutlu, Serhat
    JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (02) : 271 - 271
  • [9] Cannulated versus non-cannulated cancellous screw fixation for femoral neck fractures: a synthetic bone biomechanical study
    Gardner, A. W.
    Toh, M. Z.
    Yew, K. S. A.
    Lie, D. T. T.
    Chou, S. M.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (01) : 41 - 46
  • [10] Biomechanical analysis of the closed reduction internal fixation with cannulated screw of femoral neck fractures
    Wang, Jian-Guang
    Wu, Jun-Xian
    Li, Yu-Min
    Xu, You-Yin
    MEDICINE, 2021, 100 (08) : E24834