Quick and Accurate Placement of Cannulated Screws to Internal Fixation of Femoral Neck Fractures Using a Novel Guide Device

被引:2
|
作者
Ren, Bu-fang [1 ]
Li, Gang [1 ]
Ma, Quan-ping [1 ]
Lv, Xin [1 ]
Sun, Jian [1 ]
机构
[1] Shanxi Med Univ, Dept Orthped, Hosp 2, 382 Wuyi Rd, Taiyuan 030001, Peoples R China
关键词
Femoral neck fracture; Guide; Internal fixation; NAVIGATION;
D O I
10.1007/s12325-022-02374-0
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Introduction Fixation of femoral neck fractures with cannulated screws is an accepted method. This study aimed to compare a novel guide device and conventional technique with regard to the accuracy, operation time, fluoroscopy numbers, and drilling attempts during the insertion of cannulated screws to internal fixation of femoral neck fractures. Methods This retrospective study included 60 patients with intracapsular femoral neck fractures who were treated with cannulated screws from January 2020 to June 2021. Three screws were inserted into the femoral neck by conventional technique or using the novel guide device. The operative time, total drilling attempts, and fluoroscopy numbers were evaluated. The precision of implant placement was evaluated by screw parallelism and spread. The patients were followed for 12-24 months. Results The fluoroscopy numbers and operation time of the guide-device-assisted group were shorter than for the conventional group (p < 0.05). The total drilling attempts were significantly lower with the guide device than in the conventional group (p < 0.05). The guide-device-assisted group had better screw parallelism and greater spread than the conventional group (p < 0.05). Conclusions The novel guide device may be an effective assistant instrument for internal fixation of femoral neck fracture with cannulated screws.
引用
收藏
页码:844 / 852
页数:9
相关论文
共 50 条
  • [1] Quick and Accurate Placement of Cannulated Screws to Internal Fixation of Femoral Neck Fractures Using a Novel Guide Device
    Bu-fang Ren
    Gang Li
    Quan-ping Ma
    Xin Lv
    Jian Sun
    Advances in Therapy, 2023, 40 : 844 - 852
  • [2] Accurate Placement of Cannulated Screws in Femoral Neck Fractures: Screw and Guide Wire Combined Technique
    Chen, Yu-feng
    Ren, Dong
    Yao, Shuang-quan
    Geng, Lin-dan
    Su, Yun-shan
    Kang, Bo-yang
    Wang, Peng-cheng
    ORTHOPAEDIC SURGERY, 2021, 13 (08) : 2472 - 2476
  • [3] The Effect of Configuration of Rhombic Cannulated Screws on Internal Fixation of Femoral Neck Fractures
    Guo, Jialiang
    Dong, Weichong
    Yin, Yingchao
    Zhang, Ruipeng
    Hou, Zhiyong
    Zhang, Yingze
    ORTHOPEDICS, 2020, 43 (02) : E72 - E78
  • [4] Internal fixation using fully threaded cannulated compression screws for fresh femoral neck fractures in adults
    Kai-xuan Yuan
    Fan Yang
    Kai Fu
    Dao-yu Zhu
    Chen-yi Jiang
    Dong-xu Jin
    Ze-hao Wang
    Xiao-yuan Peng
    You-Shui Gao
    Peng-bo Luo
    Journal of Orthopaedic Surgery and Research, 17
  • [5] Internal fixation using fully threaded cannulated compression screws for fresh femoral neck fractures in adults
    Yuan, Kai-xuan
    Yang, Fan
    Fu, Kai
    Zhu, Dao-yu
    Jiang, Chen-yi
    Jin, Dong-xu
    Wang, Ze-hao
    Peng, Xiao-yuan
    Gao, You-Shui
    Luo, Peng-bo
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [6] Fixation of femoral neck fractures using divergent versus parallel cannulated screws
    Papanastassiou I.D.
    Mavrogenis A.F.
    Kokkalis Z.T.
    Nikolopoulos K.
    Skourtas K.
    Papagelopoulos P.J.
    Journal of Long-Term Effects of Medical Implants, 2011, 21 (01) : 63 - 69
  • [7] Cannulated screws fixation as an alternative treatment of femoral neck osteoporotic fractures
    Ciesielczyk, B
    Tuchocka-Piotrowska, A
    ANNALS OF THE RHEUMATIC DISEASES, 2005, 64 : 516 - +
  • [8] The Targon Femoral Neck hip screw versus cannulated screws for internal fixation of intracapsular fractures of the hip
    Griffin, X. L.
    Parsons, N.
    Achten, J.
    Costa, M. L.
    BONE & JOINT JOURNAL, 2014, 96B (05): : 652 - 657
  • [9] A Novel 3D-Printed Device for Precise Percutaneous Placement of Cannulated Compression Screws in Human Femoral Neck Fractures
    Long, Cheng
    Liu, Jin-hai
    Chai, Xiang-ping
    Liu, Xiang-feng
    Duan, Zhi-xi
    BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [10] Use of fully threaded cannulated screws decreases femoral neck shortening after fixation of femoral neck fractures
    Yoram A. Weil
    Feras Qawasmi
    Meir Liebergall
    Rami Mosheiff
    Amal Khoury
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 661 - 667