Blood Glucose Measurement Traceability to the Primary Reference Measurement Procedure (ID-MS) for Noninvasive Glucose Monitoring

被引:0
|
作者
Kuwa, Katsuhiko [1 ]
Cho, Ok Kyung [2 ]
Mitsumaki, Hiroshi [3 ]
Yasuda, Kazuo [3 ]
机构
[1] Univ Tsukuba, Inst Clin Med, Tsukuba 3058575, Japan
[2] PhiSci GmbH, Schwerte, Germany
[3] Hitachi Ltd, Tokyo, Japan
来源
POINT OF CARE | 2005年 / 4卷 / 01期
关键词
traceability; noninvasive glucose monitoring; metabolic heat conformation; uncertainty;
D O I
10.1097/01.poc.0000157100.39594.9f
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
A process for demonstrating the traceability of a glucose measurement to a reference measurement procedure and reference material is described in the International Organization for Standardization (ISO) 15197 ''in vitro diagnostic test system-requirements for blood glucose monitoring systems for self-testing in managing diabetes mellitus.'' The accuracy (precision and trueness) of the monitoring device is commuted among the established measurement procedures and the reference materials in the process to describe the degree to which the results agree with the true glucose values. This process can be applied to the current invasive type of glucose monitoring systems. Recently, we have developed a noninvasive type of glucose monitoring system called the metabolic heat conformation (MHC) method. Because the noninvasive MHC method requires only placing a fingertip over a series of sensors, the traceability process described in ISO 15197 cannot be directly applied to the MHC system because there are no means for simultaneously measuring the reference materials. Therefore, we propose a new traceability process for the noninvasive type of glucose monitoring system. Simultaneous blood collections and noninvasive measurements for patients are proposed to bridge the traceability chain. To demonstrate the validity of this approach, we conducted an evaluation of five groups of patients using the MHC method with 127 data points under actual conditions of use. Independent measurements by the noninvasive glucose monitoring system were compared with the reference glucose values determined by the hexokinase glucose-6-phosphate dehydrogenase method, which was calibrated with reference materials (the secondary calibrators). Individual uncertainties of the three levels of secondary calibrators were 0.45, 0.80, and 1.35 mg/dL, respectively, and within-run imprecisions were 0-1.48 mg/dL. Uncertainties of the regression curve (Sy/x) were 6.8-11.7 mg/dL. Combined uncertainties were estimated to be between 7.1 and 11.9 mg/dL.
引用
收藏
页码:41 / 44
页数:4
相关论文
共 50 条
  • [1] Traceability to a primary reference measurement procedure (ID-LCMS); A key step in validating the clinical accuracy and safety of hospital blood glucose monitoring systems
    Wang, Yufei
    Hu, Xiaofang
    Tang, Junling
    Wang, Weixiang
    Dong, Lu
    Gu, Chengchen
    Zhou, Jian
    Jia, Weiping
    CLINICA CHIMICA ACTA, 2018, 486 : 275 - 281
  • [2] Noninvasive methods for blood glucose measurement
    Bazaev N.A.
    Selishchev S.V.
    Biomedical Engineering, 2007, 41 (1) : 42 - 50
  • [3] Floating-reference method of noninvasive blood glucose concentration measurement
    Chen, Wen-Liang
    Yang, Yue
    Xu, Ke-Xin
    Ma, Zhen
    Nami Jishu yu Jingmi Gongcheng/Nanotechnology and Precision Engineering, 2007, 5 (04): : 298 - 301
  • [4] Transmission Spectroscopy in Noninvasive Blood Glucose Measurement
    Pozhar K.V.
    Biomedical Engineering, 2018, 52 (4) : 247 - 250
  • [5] Applying the floating-reference method to improve the precision of noninvasive blood glucose measurement
    Chen, Wenliang
    Ma, Zhen
    An, Lin
    Xu, Kexin
    OPTICAL DIAGNOSTICS AND SENSING VII, 2007, 6445
  • [6] Blood Glucose Noninvasive Measurement Based on Photoacoustic Technique
    Ding Yu
    Yao Qingkai
    Deng Lijun
    Ren Zhong
    Huang Zhen
    Zeng Luming
    Liu Guodong
    LASER & OPTOELECTRONICS PROGRESS, 2018, 55 (03)
  • [7] Methods and technical analysis of noninvasive blood glucose measurement
    Sun, F
    Kong, DY
    Mei, T
    Tao, YC
    Hu, SJ
    ISTM/2003: 5TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, CONFERENCE PROCEEDINGS, 2003, : 4295 - 4299
  • [8] Noninvasive blood glucose monitoring
    Klonoff, DC
    DIABETES CARE, 1997, 20 (03) : 433 - 437
  • [9] Should blood glucose measurement be a standard of monitoring?
    Peirce, B.
    Levy, N.
    ANAESTHESIA, 2017, 72 (05) : 658 - +
  • [10] Internal floating reference method for noninvasive measurement of blood glucose with near-infrared spectroscopy
    Luo, Yun-Han
    Li, Ship-Ing
    Huang, Fu-Rong
    Chen, Zhe
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2008, 10 (03): : 592 - 596