Blood Glucose Measurement Traceability to the Primary Reference Measurement Procedure (ID-MS) for Noninvasive Glucose Monitoring

被引:0
|
作者
Kuwa, Katsuhiko [1 ]
Cho, Ok Kyung [2 ]
Mitsumaki, Hiroshi [3 ]
Yasuda, Kazuo [3 ]
机构
[1] Univ Tsukuba, Inst Clin Med, Tsukuba 3058575, Japan
[2] PhiSci GmbH, Schwerte, Germany
[3] Hitachi Ltd, Tokyo, Japan
来源
POINT OF CARE | 2005年 / 4卷 / 01期
关键词
traceability; noninvasive glucose monitoring; metabolic heat conformation; uncertainty;
D O I
10.1097/01.poc.0000157100.39594.9f
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
A process for demonstrating the traceability of a glucose measurement to a reference measurement procedure and reference material is described in the International Organization for Standardization (ISO) 15197 ''in vitro diagnostic test system-requirements for blood glucose monitoring systems for self-testing in managing diabetes mellitus.'' The accuracy (precision and trueness) of the monitoring device is commuted among the established measurement procedures and the reference materials in the process to describe the degree to which the results agree with the true glucose values. This process can be applied to the current invasive type of glucose monitoring systems. Recently, we have developed a noninvasive type of glucose monitoring system called the metabolic heat conformation (MHC) method. Because the noninvasive MHC method requires only placing a fingertip over a series of sensors, the traceability process described in ISO 15197 cannot be directly applied to the MHC system because there are no means for simultaneously measuring the reference materials. Therefore, we propose a new traceability process for the noninvasive type of glucose monitoring system. Simultaneous blood collections and noninvasive measurements for patients are proposed to bridge the traceability chain. To demonstrate the validity of this approach, we conducted an evaluation of five groups of patients using the MHC method with 127 data points under actual conditions of use. Independent measurements by the noninvasive glucose monitoring system were compared with the reference glucose values determined by the hexokinase glucose-6-phosphate dehydrogenase method, which was calibrated with reference materials (the secondary calibrators). Individual uncertainties of the three levels of secondary calibrators were 0.45, 0.80, and 1.35 mg/dL, respectively, and within-run imprecisions were 0-1.48 mg/dL. Uncertainties of the regression curve (Sy/x) were 6.8-11.7 mg/dL. Combined uncertainties were estimated to be between 7.1 and 11.9 mg/dL.
引用
收藏
页码:41 / 44
页数:4
相关论文
共 50 条
  • [31] Noninvasive blood glucose measurement by ultrasound-modulated optical technique
    朱莉莉
    林洁清
    林栢清
    李晖
    Chinese Optics Letters, 2013, 11 (02) : 68 - 72
  • [32] Research on noninvasive blood glucose measurement with simulate sample by NIR spectroscopy
    Zhang, Y
    Lü, LN
    Xu, KX
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25 (04) : 512 - 515
  • [33] Application of muscle biopotential measurement for sustained, noninvasive blood glucose survey
    Vol, Alexander
    Gribova, Orna
    Berman, Sylvia
    Siman-Tov, Yariv
    Efrati, Shai
    JOURNAL OF APPLIED PHYSIOLOGY, 2009, 107 (01) : 253 - 260
  • [34] Noninvasive Blood Glucose Level Measurement Using Nuclear Magnetic Resonance
    Luaibi, Ahmed Y.
    Al-Ghusain, Ahmed J.
    Rahman, Asif
    Al-Sayah, Mohammad H.
    Al-Nashash, Hasan A.
    2015 IEEE 8TH GCC CONFERENCE AND EXHIBITION (GCCCE), 2015,
  • [35] Research on Continuum Power Regression in Noninvasive Measurement of Human Blood Glucose
    Li Qing-bo
    Liu Jie-qiang
    Zhang Guang-jun
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31 (06) : 1481 - 1485
  • [36] Investigations on Multisensor-Based Noninvasive Blood Glucose Measurement System
    Yadav, Jyoti
    Rani, Asha
    Singh, Vijander
    Murari, Bhaskar Mohan
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2017, 11 (03):
  • [37] A Feasibility Study on Noninvasive Blood Glucose Measurement Using Photoacoustic Method
    Kulkarni, Omkar C.
    Mandal, Pralay
    Das, Shib Shankar
    Banerjee, Swapna
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [38] A Noninvasive Blood Glucose Measurement System by Arduino and Near-infrared
    Zheng, Tuhong
    Li, Weixi
    Liu, Yuwei
    Ling, Bingo Wing-Kuen
    2016 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS-CHINA (ICCE-CHINA), 2016,
  • [39] Development of a candidate reference measurement procedure by ID-LC-MS/MS for total tau protein measurement in cerebrospinal fluid (CSF)
    Giangrande, Chiara
    Vaneeckhoutte, Helene
    Boeuf, Amandine
    Lalere, Beatrice
    Hirtz, Christophe
    Lehmann, Sylvain
    Quaglia, Milena
    Delatour, Vincent
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (07) : 1235 - 1244
  • [40] GLUCOSE MEASUREMENT ACCURACY OF A NOVEL IN-LINE WHOLE BLOOD GLUCOSE MONITORING SYSTEM
    Hendee, Shonn
    Vanslyke, Stephen
    Faught, Joelle
    Borrello, Mike
    Macemon, Jim
    Thompson, Rick
    Truong, Annie
    Wang, Christopher
    CRITICAL CARE MEDICINE, 2010, 38 (12) : U243 - U243