Blood Glucose Measurement Traceability to the Primary Reference Measurement Procedure (ID-MS) for Noninvasive Glucose Monitoring

被引:0
|
作者
Kuwa, Katsuhiko [1 ]
Cho, Ok Kyung [2 ]
Mitsumaki, Hiroshi [3 ]
Yasuda, Kazuo [3 ]
机构
[1] Univ Tsukuba, Inst Clin Med, Tsukuba 3058575, Japan
[2] PhiSci GmbH, Schwerte, Germany
[3] Hitachi Ltd, Tokyo, Japan
来源
POINT OF CARE | 2005年 / 4卷 / 01期
关键词
traceability; noninvasive glucose monitoring; metabolic heat conformation; uncertainty;
D O I
10.1097/01.poc.0000157100.39594.9f
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
A process for demonstrating the traceability of a glucose measurement to a reference measurement procedure and reference material is described in the International Organization for Standardization (ISO) 15197 ''in vitro diagnostic test system-requirements for blood glucose monitoring systems for self-testing in managing diabetes mellitus.'' The accuracy (precision and trueness) of the monitoring device is commuted among the established measurement procedures and the reference materials in the process to describe the degree to which the results agree with the true glucose values. This process can be applied to the current invasive type of glucose monitoring systems. Recently, we have developed a noninvasive type of glucose monitoring system called the metabolic heat conformation (MHC) method. Because the noninvasive MHC method requires only placing a fingertip over a series of sensors, the traceability process described in ISO 15197 cannot be directly applied to the MHC system because there are no means for simultaneously measuring the reference materials. Therefore, we propose a new traceability process for the noninvasive type of glucose monitoring system. Simultaneous blood collections and noninvasive measurements for patients are proposed to bridge the traceability chain. To demonstrate the validity of this approach, we conducted an evaluation of five groups of patients using the MHC method with 127 data points under actual conditions of use. Independent measurements by the noninvasive glucose monitoring system were compared with the reference glucose values determined by the hexokinase glucose-6-phosphate dehydrogenase method, which was calibrated with reference materials (the secondary calibrators). Individual uncertainties of the three levels of secondary calibrators were 0.45, 0.80, and 1.35 mg/dL, respectively, and within-run imprecisions were 0-1.48 mg/dL. Uncertainties of the regression curve (Sy/x) were 6.8-11.7 mg/dL. Combined uncertainties were estimated to be between 7.1 and 11.9 mg/dL.
引用
收藏
页码:41 / 44
页数:4
相关论文
共 50 条
  • [21] Fluorescence spectroscopy for noninvasive glucose measurement
    Bagheri, Z.
    Massudi, R.
    Ghanavi, J.
    Latifi, H.
    CLINICAL AND BIOMEDICAL SPECTROSCOPY AND IMAGING III, 2013, 8798
  • [22] Should blood glucose measurement be a standard of monitoring? A reply
    Checketts, M.
    ANAESTHESIA, 2017, 72 (05) : 659 - 659
  • [23] Self-monitoring of blood glucose compared with continuous tissue glucose measurement
    Sternberg, F
    Hoss, U
    Salgado, M
    Pfeiffer, EF
    DIABETES CARE, 1997, 20 (07) : 1208 - 1209
  • [24] Measurement Accuracy of a Newly Developed Prototype System for Noninvasive Glucose Monitoring
    Freckmann, Guido
    Pleus, Stefan
    Wintergerst, Peter
    Waldenmaier, Delia
    Jendrike, Nina R.
    Link, Manuela
    Haug, Cornelia
    DIABETES, 2019, 68
  • [25] A Noninvasive Accurate Measurement of Blood Glucose Levels with Raman Spectroscopy of Blood in Microvessels
    Li, Nan
    Zang, Hang
    Sun, Huimin
    Jiao, Xianzhi
    Wang, Kangkang
    Liu, Timon Cheng-Yi
    Meng, Yaoyong
    MOLECULES, 2019, 24 (08):
  • [26] Accuracy of Blood Glucose Measurement and Blood Glucose Targets
    Eerdekens, Gert-Jan
    Rex, Steffen
    Mesotten, Dieter
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2020, 14 (03): : 553 - 559
  • [27] ISOTOPE DILUTION MASS-SPECTROMETRY (ID-MS) AS A DEFINITIVE ANALYTICAL METHOD FOR GLUCOSE IN SERUM
    SUN, T
    COHEN, A
    HERTZ, H
    SCHAFFER, R
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1977, 173 (MAR20): : 165 - 165
  • [28] Measurement Procedure for Glucose in Serum Using Liquid Chromatography Isotope Dilution - Tandem Mass Spectrometry (LC-ID-MS/MS)
    Kress, M.
    Meissner, D.
    Kramer, U.
    Spannagl, M.
    Kaiser, P.
    CLINICAL LABORATORY, 2014, 60 (09) : 1509 - 1515
  • [29] Noninvasive blood glucose measurement by ultrasound-modulated optical technique
    Zhu, Lili
    Lin, Jieqing
    Lin, Baiqing
    Li, Hui
    CHINESE OPTICS LETTERS, 2013, 11 (02)
  • [30] Study on the noninvasive blood glucose measurement by diffusion reflectance NIR spectroscopy
    Zhang, HY
    Song, LQ
    Wang, HY
    Wang, C
    Tang, YG
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT II , PTS 1 AND 2, 2005, 5630 : 460 - 467