Blood Glucose Measurement Traceability to the Primary Reference Measurement Procedure (ID-MS) for Noninvasive Glucose Monitoring

被引:0
|
作者
Kuwa, Katsuhiko [1 ]
Cho, Ok Kyung [2 ]
Mitsumaki, Hiroshi [3 ]
Yasuda, Kazuo [3 ]
机构
[1] Univ Tsukuba, Inst Clin Med, Tsukuba 3058575, Japan
[2] PhiSci GmbH, Schwerte, Germany
[3] Hitachi Ltd, Tokyo, Japan
来源
POINT OF CARE | 2005年 / 4卷 / 01期
关键词
traceability; noninvasive glucose monitoring; metabolic heat conformation; uncertainty;
D O I
10.1097/01.poc.0000157100.39594.9f
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
A process for demonstrating the traceability of a glucose measurement to a reference measurement procedure and reference material is described in the International Organization for Standardization (ISO) 15197 ''in vitro diagnostic test system-requirements for blood glucose monitoring systems for self-testing in managing diabetes mellitus.'' The accuracy (precision and trueness) of the monitoring device is commuted among the established measurement procedures and the reference materials in the process to describe the degree to which the results agree with the true glucose values. This process can be applied to the current invasive type of glucose monitoring systems. Recently, we have developed a noninvasive type of glucose monitoring system called the metabolic heat conformation (MHC) method. Because the noninvasive MHC method requires only placing a fingertip over a series of sensors, the traceability process described in ISO 15197 cannot be directly applied to the MHC system because there are no means for simultaneously measuring the reference materials. Therefore, we propose a new traceability process for the noninvasive type of glucose monitoring system. Simultaneous blood collections and noninvasive measurements for patients are proposed to bridge the traceability chain. To demonstrate the validity of this approach, we conducted an evaluation of five groups of patients using the MHC method with 127 data points under actual conditions of use. Independent measurements by the noninvasive glucose monitoring system were compared with the reference glucose values determined by the hexokinase glucose-6-phosphate dehydrogenase method, which was calibrated with reference materials (the secondary calibrators). Individual uncertainties of the three levels of secondary calibrators were 0.45, 0.80, and 1.35 mg/dL, respectively, and within-run imprecisions were 0-1.48 mg/dL. Uncertainties of the regression curve (Sy/x) were 6.8-11.7 mg/dL. Combined uncertainties were estimated to be between 7.1 and 11.9 mg/dL.
引用
收藏
页码:41 / 44
页数:4
相关论文
共 50 条
  • [41] Measurement of glucose concentration in interstitial fluid - an alternative or a supplement to conventional blood glucose monitoring?
    Kublin, Oskar
    Stepien, Mariusz
    CLINICAL DIABETOLOGY, 2019, 8 (02): : 121 - 126
  • [42] Glucose measurement in interstitial fluid by microdialysis for the calibration of minimally invasive blood glucose monitoring
    Li, Dachao
    Wang, Ridong
    Chong, Hao
    Liu, Yu
    Xu, Kexin
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS XI, 2013, 8572
  • [43] Measurement of glucose with noninvasive transdermal extraction .2. Correlation between sensor response and blood glucose
    Chiang, CM
    Chen, TF
    Berner, B
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 335 - PMSE
  • [44] GLUCOSE MEASUREMENT IN DILUTED BLOOD
    SCHELLER, FW
    PFEIFFER, D
    HINTSCHE, R
    DRANSFELD, I
    NENTWIG, J
    BIOMEDICA BIOCHIMICA ACTA, 1989, 48 (11-12) : 891 - 896
  • [45] MEASUREMENT OF BLOOD-GLUCOSE
    BURRIN, JM
    PRICE, CP
    ANNALS OF CLINICAL BIOCHEMISTRY, 1985, 22 (JUL) : 327 - 342
  • [46] BLOOD-GLUCOSE MEASUREMENT
    AITKIN, CGG
    VETERINARY RECORD, 1983, 112 (04) : 88 - 88
  • [47] Measurement Performance of Two Continuous Tissue Glucose Monitoring Systems Intended for Replacement of Blood Glucose Monitoring
    Freckmann, Guido
    Link, Manuela
    Pleus, Stefan
    Westhoff, Antje
    Kamecke, Ulrike
    Haug, Cornelia
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 (08) : 541 - 549
  • [48] Noninvasive photoacoustic measurement of glucose by data fusion
    Zhang, Ruochong
    Gao, Fei
    Feng, Xiaohua
    Liu, Siyu
    Kishor, Rahul
    Luo, Yunqi
    Zheng, Yuanjin
    ANALYST, 2017, 142 (16) : 2892 - 2896
  • [49] The Glucose Monitoring System Reduces the Incidents of Glucose Measurement
    Okura, Tsuyoshi
    Teramoto, Kei
    Koshitani, Rie
    Kawamoto, Sonoko
    Ito, Yuichi
    Fujioka, Yohei
    Sumi, Keisuke
    Shoji, Kyoko
    Nakamura, Risa
    Matsumoto, Kazuhisa
    Matsuzawa, Kazuhiko
    Izawa, Shoichiro
    Kato, Masahiko
    Taniguchi, Shinichi
    Yamamoto, Kazuhiro
    DIABETES, 2017, 66 : A237 - A237
  • [50] Ratio of Blood Glucose Level Change Measurement for Flap Monitoring
    Karakawa, Ryo
    Yoshimatsu, Hidehiko
    Narushima, Mitsunaga
    Iida, Takuya
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2018, 6 (07)