Blood Glucose Measurement Traceability to the Primary Reference Measurement Procedure (ID-MS) for Noninvasive Glucose Monitoring

被引:0
|
作者
Kuwa, Katsuhiko [1 ]
Cho, Ok Kyung [2 ]
Mitsumaki, Hiroshi [3 ]
Yasuda, Kazuo [3 ]
机构
[1] Univ Tsukuba, Inst Clin Med, Tsukuba 3058575, Japan
[2] PhiSci GmbH, Schwerte, Germany
[3] Hitachi Ltd, Tokyo, Japan
来源
POINT OF CARE | 2005年 / 4卷 / 01期
关键词
traceability; noninvasive glucose monitoring; metabolic heat conformation; uncertainty;
D O I
10.1097/01.poc.0000157100.39594.9f
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
A process for demonstrating the traceability of a glucose measurement to a reference measurement procedure and reference material is described in the International Organization for Standardization (ISO) 15197 ''in vitro diagnostic test system-requirements for blood glucose monitoring systems for self-testing in managing diabetes mellitus.'' The accuracy (precision and trueness) of the monitoring device is commuted among the established measurement procedures and the reference materials in the process to describe the degree to which the results agree with the true glucose values. This process can be applied to the current invasive type of glucose monitoring systems. Recently, we have developed a noninvasive type of glucose monitoring system called the metabolic heat conformation (MHC) method. Because the noninvasive MHC method requires only placing a fingertip over a series of sensors, the traceability process described in ISO 15197 cannot be directly applied to the MHC system because there are no means for simultaneously measuring the reference materials. Therefore, we propose a new traceability process for the noninvasive type of glucose monitoring system. Simultaneous blood collections and noninvasive measurements for patients are proposed to bridge the traceability chain. To demonstrate the validity of this approach, we conducted an evaluation of five groups of patients using the MHC method with 127 data points under actual conditions of use. Independent measurements by the noninvasive glucose monitoring system were compared with the reference glucose values determined by the hexokinase glucose-6-phosphate dehydrogenase method, which was calibrated with reference materials (the secondary calibrators). Individual uncertainties of the three levels of secondary calibrators were 0.45, 0.80, and 1.35 mg/dL, respectively, and within-run imprecisions were 0-1.48 mg/dL. Uncertainties of the regression curve (Sy/x) were 6.8-11.7 mg/dL. Combined uncertainties were estimated to be between 7.1 and 11.9 mg/dL.
引用
收藏
页码:41 / 44
页数:4
相关论文
共 50 条
  • [11] Internal floating reference method for noninvasive measurement of blood glucose with near-infrared spectroscopy
    Luo, Yun-Han
    Li, Shiping
    Huang, Furong
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2007, 1 (06): : 307 - 311
  • [12] Flexible Microwave Plasmonic Sensor for Noninvasive Measurement of Blood Glucose
    Zhou, Yong Jin
    Xu, Jian
    Dai, Li Hui
    2021 13TH GLOBAL SYMPOSIUM ON MILLIMETER-WAVES & TERAHERTZ (GSMM), 2021,
  • [13] A Noninvasive Measurement of Blood Glucose Concentration by UWB Microwave Spectrum
    Xiao, Xia
    Li, Qinwei
    IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2017, 16 : 1040 - 1043
  • [14] Temperature effect on the noninvasive measurement of human blood glucose by NIR
    Cui, HX
    Xu, KX
    Chen, MS
    An, L
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2006, 26 (05) : 838 - 841
  • [15] Noninvasive measurement of blood glucose by dynamic pulse impedance spectroscopy
    Li, G
    Lu, ZW
    Lin, L
    PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 3, 2004, : 691 - 696
  • [16] Development of noninvasive procedure for monitoring blood glucose levels using saliva
    Yamaguchi, M
    Mitsumori, M
    Kano, Y
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 1763 - 1766
  • [17] MEASUREMENT OF BLOOD GLUCOSE
    HEINTGES, MG
    OVERFIELD, CV
    CLINICAL CHEMISTRY, 1971, 17 (07) : 648 - +
  • [18] MEASUREMENT OF BLOOD GLUCOSE
    WENK, RE
    NEW ENGLAND JOURNAL OF MEDICINE, 1969, 281 (06): : 328 - &
  • [19] NONINVASIVE DETERMINATION OF BLOOD-GLUCOSE - MEASUREMENT OF GLUCOSE IN WHOLE-BLOOD BY IR-SPECTROMETRY
    KRUSEJARRES, JD
    JANATSCH, G
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1986, 24 (10): : 786 - 786
  • [20] NONINVASIVE GLUCOSE MEASUREMENT IN NEWBORN INFANTS
    Varma, D.
    Carns, J.
    Zhang, L.
    Gerhardt, K.
    Bao, G.
    Tabor, J.
    Khan, A. M.
    Reynolds, E. W.
    Richards-Kortum, R.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2019, 67 (02) : 537 - 537