Traceability to a primary reference measurement procedure (ID-LCMS); A key step in validating the clinical accuracy and safety of hospital blood glucose monitoring systems

被引:0
|
作者
Wang, Yufei [1 ]
Hu, Xiaofang [2 ]
Tang, Junling [1 ]
Wang, Weixiang [3 ]
Dong, Lu [1 ]
Gu, Chengchen [1 ]
Zhou, Jian [1 ]
Jia, Weiping [1 ]
机构
[1] Shanghai Jiao Tong Univ, Affiliated Peoples Hosp 6, Shanghai Clin Ctr Diabet,Dept Endocrinol & Metab, Shanghai Diabet Inst,Shanghai Key Lab Diabet Mell, Shanghai 200233, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Environm Sci & Engn, Shanghai 200240, Peoples R China
[3] Shanghai Jiao Tong Univ, Affiliated Peoples Hosp 6, Dept Lab Med, Shanghai 200233, Peoples R China
关键词
Critically ill; Blood glucose monitoring; Intensive insulin therapy; Insulin dosing error; Isotope dilution liquid chromatography tandem mass spectrometry; Blood glucose monitoring system; VITAMIN-C;
D O I
10.1016/j.cca.2018.08.025
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objective: A key step in the evaluation of the accuracy of blood glucose monitoring systems (BGMS) is using a comparator method aligned to a high order definitive reference method. We describe how we achieved traceability to an isotope dilution liquid chromatography mass spectrometry (ID-LCMS) method. We used ID-LCMS to evaluate the accuracy and specificity of two hospital BGMS used in China. Method: ID-LCMS was used to verify the calibration alignment of the laboratory plasma hexokinase reference method using NIST standard reference material and clinical samples. The ID-LCMS aligned hexokinase method was used to evaluate the clinical accuracy of two BGMS in hospitalized patients. System accuracy was evaluated using Chinese consensus guidelines. BGMS accuracy was also assessed with interference factors known to be present in critically ill patients' blood. Results: The laboratory plasma hexokinase reference method was shown to calibrate closely with ID-LCMS. Two BGMS demonstrated good correlation with this reference method. Only one BGMS met the Chinese guidelines. The interference factors didn't influence this BGMS but adversely affected the clinical accuracy of the other. Conclusions: We advocate that our IDMS calibration alignment approach for ensuring the accuracy of the glucose reference method should be adopted in evaluations assessing the accuracy of blood glucose monitoring systems.
引用
收藏
页码:275 / 281
页数:7
相关论文
共 2 条
  • [1] Blood Glucose Measurement Traceability to the Primary Reference Measurement Procedure (ID-MS) for Noninvasive Glucose Monitoring
    Kuwa, Katsuhiko
    Cho, Ok Kyung
    Mitsumaki, Hiroshi
    Yasuda, Kazuo
    POINT OF CARE, 2005, 4 (01): : 41 - 44
  • [2] Impact of Two Different Reference Measurement Procedures on Apparent System Accuracy of 18 CE-Marked Current-Generation Blood Glucose Monitoring Systems
    Freckmann, Guido
    Baumstark, Annette
    Jendrike, Nina
    Mende, Jochen
    Schauer, Sebastian
    Link, Manuela
    Pleus, Stefan
    Haug, Cornelia
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (05): : 1076 - 1088