A retrospective analysis for patient-specific quality assurance of volumetric-modulated arc therapy plans

被引:9
|
作者
Li, Guangjun [1 ,2 ]
Wu, Kui [3 ]
Peng, Guang [1 ,2 ]
Zhang, Yingjie [1 ,2 ]
Bai, Sen [1 ,2 ]
机构
[1] Sichuan Univ, West China Hosp, Ctr Canc, Radiat Phys Ctr, Chengdu 610041, Sichuan, Peoples R China
[2] Sichuan Univ, West China Hosp, State Key Lab Biotherapy, Chengdu 610041, Sichuan, Peoples R China
[3] Zhejiang Univ, Sch Med, Affiliated Hosp 2, Dept Radiotherapy, Hangzhou 310003, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Volumetric-modulated arc therapy; Quality assurance; Gamma analysis; Leaf travel; VMAT VERIFICATION; DIODE-ARRAY; IMRT; DOSIMETRY; QA; RADIOTHERAPY; PHANTOM; IMPLEMENTATION; TOMOTHERAPY; SOFTWARE;
D O I
10.1016/j.meddos.2014.05.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Volumetric-modulated arc therapy (VMAT) is now widely used clinically, as it is capable of delivering a highly conformal dose distribution in a short time interval. We retrospectively analyzed patient-specific quality assurance (QA) of VMAT and examined the relationships between the planning parameters and the QA results. A total of 118 clinical VMAT cases underwent pretreatment QA. All plans had 3-dimensional diode array measurements, and 69 also had ion chamber measurements. Dose distribution and isocenter point dose were evaluated by comparing the measurements and the treatment planning system (TPS) calculations. In addition, the relationship between QA results and several planning parameters, such as dose level, control points (CPs), monitor units (MUs), average field width, and average leaf travel, were also analyzed. For delivered dose distribution, a gamma analysis passing rate greater than 90% was obtained for all plans and greater than 95% for 100 of 118 plans with the 3%/3-mm criteria. The difference (mean +/- standard deviation) between the point doses measured by the ion chamber and those calculated by TPS was 0.9% +/- 2.0% for all plans. For all cancer sites, nasopharyngeal carcinoma and gastric cancer have the lowest and highest average passing rates, respectively. From multivariate linear regression analysis, the dose level (p = 0.001) and the average leaf travel (p < 0.001) showed negative correlations with the passing rate, and the average field width (p = 0.003) showed a positive correlation with the passing rate, all indicating a correlation between the passing rate and the plan complexity. No statistically significant correlation was found between MU or CP and the passing rate. Analysis of the results of dosimetric pretreatment measurements as a function of VMAT plan parameters can provide important information to guide the plan parameter setting and optimization in TPS. (C) 2014 American Association of Medical Dosimetrists.
引用
收藏
页码:309 / 313
页数:5
相关论文
共 50 条
  • [21] Impact of treatment planning quality assurance software on volumetric-modulated arc therapy plans for prostate cancer patients
    Sasaki, Motoharu
    Nakaguchi, Yuji
    Kamomae, Takeshi
    Kajino, Akimi
    Ikushima, Hitoshi
    MEDICAL DOSIMETRY, 2021, 46 (04) : E1 - E6
  • [22] Verification of patient specific quality assurance system for volumetric modulated arc therapy (VMAT)
    Amoabeng, Kwame Anokye
    Marthinsen, Anne Beate Langeland
    Hasford, Francis
    Tagoe, Samuel Nii Adu
    Anaafi, Evelyn
    HEALTH AND TECHNOLOGY, 2022, 12 (04) : 779 - 786
  • [23] Verification of patient specific quality assurance system for volumetric modulated arc therapy (VMAT)
    Kwame Anokye Amoabeng
    Anne Beate Langeland Marthinsen
    Francis Hasford
    Samuel Nii Adu Tagoe
    Evelyn Anaafi
    Health and Technology, 2022, 12 : 779 - 786
  • [24] Effect of dose grid resolution on the results of patient-specific quality assurance for intensity-modulated radiation therapy and volumetric modulated arc therapy
    Chun, M.
    Kim, J., I
    Oh, G. H.
    Wu, H. G.
    Park, J. M.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 18 (03): : 521 - 530
  • [25] Integrating plan complexity and dosiomics features with deep learning in patient-specific quality assurance for volumetric modulated arc therapy
    Han, Ce
    Zhang, Ji
    Yu, Bing
    Zheng, Haoze
    Wu, Yibo
    Lin, Zhixi
    Ning, Boda
    Yi, Jinling
    Xie, Congying
    Jin, Xiance
    RADIATION ONCOLOGY, 2023, 18 (01)
  • [26] Dosimetric Validation for Patient-specific Quality Assurance using the Delta44 Phantom with Volumetric Modulated Arc Therapy
    Arino Gil, A.
    Calvo, O.
    Gutierrez, A.
    Papanikolau, N.
    Hdez-Armas, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S717 - S717
  • [27] Integrating plan complexity and dosiomics features with deep learning in patient-specific quality assurance for volumetric modulated arc therapy
    Ce Han
    Ji Zhang
    Bing Yu
    Haoze Zheng
    Yibo Wu
    Zhixi Lin
    Boda Ning
    Jinling Yi
    Congying Xie
    Xiance Jin
    Radiation Oncology, 18
  • [28] Correlation analysis between 2D and 3D patient-specific quality assurance for volumetric modulated arc therapy
    Sharma, S.
    Sharma, D.
    Subramani, V.
    Gopishankar, N.
    Bhaskar, S.
    Pathy, S.
    Kumar, P.
    Thulkar, S.
    Chander, S.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2023, 21 (04): : 685 - 691
  • [29] From 2D to 3D gamma passing rate tolerance and action limits for patient-specific quality assurance in volumetric-modulated arc therapy
    Zarros, Christos
    Patatoukas, George
    Kollaros, Nikos
    Chalkia, Marina
    Kougioumtzopoulou, Andromachi
    Kouloulias, Vasilios
    Platoni, Kalliopi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025,
  • [30] Cloud-Based Monte Carlo Patient-Specific Quality Assurance (QA) Method for Volumetric Modulated Arc Therapy (VMAT)
    Chen, X.
    Xing, L.
    Azcona, J.
    Luxton, G.
    Bush, K.
    MEDICAL PHYSICS, 2014, 41 (06) : 237 - 238