Thermionic sodium ion source versus corona discharge in detection of alkaloids using ion mobility spectrometry

被引:4
|
作者
Asadi, Masood [1 ]
Valadbeigi, Younes [2 ]
Tabrizchi, Mahmoud [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
[2] Imam Khomeini Int Univ, Fac Sci, Dept Chem, POB 288, Qazvin, Iran
关键词
Thermal ionization; Ion mobility spectrometry; Sodium ion; Alkaloids; Ionization source; IONIZATION SOURCE;
D O I
10.1007/s12127-019-00249-9
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
IMS spectra obtained by using a thermal ionization sodium ion (SI) source and a corona discharge (CD) source were compared in terms of resolution, selectivity and sensitivity. The reactant ion peak (RIP) for the SI source is a single narrow peak which appears in a shorter drift time compared to the main RIP of the CD ion source, (H2O)(n)H3O+. Comparison of the IMS spectra of selected alkaloids obtained with both the CD and the SI sources shows that the latter exhibits simpler pattern, including a narrow single peak for each compound, well separated from other samples peak. Furthermore, the product ion peaks (PIP) in the SI source appeared at higher drift times leading to higher peak-to-peak resolution. However, the sodium ion source is less sensitive to the selected alkaloids compared to the CD ion source.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 50 条
  • [1] Ion mobility spectrometer using pulse corona discharge ion source
    Li, Da-Chao
    Li, Guo-Qing
    Tan, Jing-Hui
    Yu, Hai-Xia
    Xu, Ke-Xin
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2013, 21 (12): : 3095 - 3101
  • [2] Detection of explosives by positive corona discharge ion mobility spectrometry
    Tabrizchi, Mahmoud
    ILbeigi, Vahideh
    JOURNAL OF HAZARDOUS MATERIALS, 2010, 176 (1-3) : 692 - 696
  • [3] DETECTION OF TOLUENE, METHANOL AND FORMALDEHYDE USING CORONA DISCHARGE ION MOBILITY SPECTROMETRY
    Li, Shu
    Jia, Jian
    Gao, Xiaoguang
    He, Xiuli
    Li, Jianping
    ANALYTICAL LETTERS, 2012, 45 (08) : 841 - 849
  • [4] Combined corona discharge and UV photoionization source for ion mobility spectrometry
    Bahrami, Hamed
    Tabrizchi, Mahmoud
    TALANTA, 2012, 97 : 400 - 405
  • [5] Design and optimization of a corona discharge ionization source for ion mobility spectrometry
    Tabrizchi, M
    Khayamian, T
    Taj, N
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (06): : 2321 - 2328
  • [6] Glowing discharge ion source of ion mobility spectrometry
    衡磊
    辽宁师范大学学报(自然科学版), 2008, 31 (04) : 485 - 486
  • [7] Development of a short pulsed corona discharge ionization source for ion mobility spectrometry
    An, YA
    Aliaga-Rossel, R
    Choi, P
    Gilles, JP
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (08): : 1 - 6
  • [8] Analysis of biogenic amines using corona discharge ion mobility spectrometry
    Hashemian, Z.
    Mardihallaj, A.
    Khayamian, T.
    TALANTA, 2010, 81 (03) : 1081 - 1087
  • [9] Determination of alcohol compounds using corona discharge ion mobility spectrometry
    Han Hai-yan
    Huang Guo-dong
    Jin Shun-ping
    Zheng Pei-chao
    Xu Guo-hua
    Li Jian-quan
    Wang Hong-mei
    Chu Yan-nan
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2007, 19 (06) : 751 - 755