Thermionic sodium ion source versus corona discharge in detection of alkaloids using ion mobility spectrometry

被引:4
|
作者
Asadi, Masood [1 ]
Valadbeigi, Younes [2 ]
Tabrizchi, Mahmoud [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
[2] Imam Khomeini Int Univ, Fac Sci, Dept Chem, POB 288, Qazvin, Iran
关键词
Thermal ionization; Ion mobility spectrometry; Sodium ion; Alkaloids; Ionization source; IONIZATION SOURCE;
D O I
10.1007/s12127-019-00249-9
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
IMS spectra obtained by using a thermal ionization sodium ion (SI) source and a corona discharge (CD) source were compared in terms of resolution, selectivity and sensitivity. The reactant ion peak (RIP) for the SI source is a single narrow peak which appears in a shorter drift time compared to the main RIP of the CD ion source, (H2O)(n)H3O+. Comparison of the IMS spectra of selected alkaloids obtained with both the CD and the SI sources shows that the latter exhibits simpler pattern, including a narrow single peak for each compound, well separated from other samples peak. Furthermore, the product ion peaks (PIP) in the SI source appeared at higher drift times leading to higher peak-to-peak resolution. However, the sodium ion source is less sensitive to the selected alkaloids compared to the CD ion source.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 50 条
  • [31] Specific O2- generation in corona discharge for ion mobility spectrometry
    Sabo, Martin
    Matuska, Jan
    Matejcik, Stefan
    TALANTA, 2011, 85 (01) : 400 - 405
  • [32] Effect of ionic wind on the sample distribution in corona discharge ion mobility spectrometry
    Wang, Jiyao
    Zhang, Chong
    Shi, Wenyan
    Ling, Yiyuan
    Wang, Xiaohao
    Ni, Kai
    TALANTA, 2025, 284
  • [33] Reverse flow continuous corona discharge ionisation applied to ion mobility spectrometry
    Ross, SK
    Bell, AJ
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 218 (02) : L1 - L6
  • [34] Corona discharge ion mobility spectrometry for the determination of theophylline and guaifenesin in human serum
    Sheibani, A.
    Masoumi, S.
    Partovi, S.
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2013, 16 (04) : 259 - 263
  • [35] ION MOBILITY SPECTROMETRY STUDY OF NEGATIVE CORONA DISCHARGE IN OXYGEN/NITROGEN MIXTURES
    Stano, Michal
    Safonov, Eugene
    Kucera, Marek
    Matejcik, Stefan
    CHEMICKE LISTY, 2008, 102 : S1414 - S1417
  • [36] Design for Gas Chromatography-Corona Discharge-Ion Mobility Spectrometry
    Jafari, Mohammad T.
    Saraji, Mohammad
    Sherafatmand, Hossein
    ANALYTICAL CHEMISTRY, 2012, 84 (22) : 10077 - 10084
  • [37] MEMS ion source for ion mobility spectrometry
    Grzebyk, Tomasz
    Szyszka, Piotr
    Krysztof, Michal
    Gorecka-Drzazga, Anna
    Dziuban, Jan
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2019, 37 (02):
  • [38] MEMS ion source for ion mobility spectrometry
    Grzebyk, Tomasz
    Szyszka, Piotr
    Krysztof, Michal
    Gorecka-Drzazga, Anna
    Dziuban, Jan A.
    2018 31ST INTERNATIONAL VACUUM NANOELECTRONICS CONFERENCE (IVNC), 2018,
  • [39] ION MOBILITY MEASUREMENTS IN A POSITIVE CORONA DISCHARGE
    STEARNS, RG
    JOURNAL OF APPLIED PHYSICS, 1990, 67 (06) : 2789 - 2799
  • [40] Detection of perfluorocarbons using ion mobility spectrometry
    Schmidt, H
    Baumbach, JI
    Klockow, D
    ANALYTICA CHIMICA ACTA, 2003, 484 (01) : 63 - 74