Thermionic sodium ion source versus corona discharge in detection of alkaloids using ion mobility spectrometry

被引:4
|
作者
Asadi, Masood [1 ]
Valadbeigi, Younes [2 ]
Tabrizchi, Mahmoud [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
[2] Imam Khomeini Int Univ, Fac Sci, Dept Chem, POB 288, Qazvin, Iran
关键词
Thermal ionization; Ion mobility spectrometry; Sodium ion; Alkaloids; Ionization source; IONIZATION SOURCE;
D O I
10.1007/s12127-019-00249-9
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
IMS spectra obtained by using a thermal ionization sodium ion (SI) source and a corona discharge (CD) source were compared in terms of resolution, selectivity and sensitivity. The reactant ion peak (RIP) for the SI source is a single narrow peak which appears in a shorter drift time compared to the main RIP of the CD ion source, (H2O)(n)H3O+. Comparison of the IMS spectra of selected alkaloids obtained with both the CD and the SI sources shows that the latter exhibits simpler pattern, including a narrow single peak for each compound, well separated from other samples peak. Furthermore, the product ion peaks (PIP) in the SI source appeared at higher drift times leading to higher peak-to-peak resolution. However, the sodium ion source is less sensitive to the selected alkaloids compared to the CD ion source.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 50 条
  • [21] Analysis of explosives using corona discharge ionization combined with ion mobility spectrometry-mass spectrometry
    Lee, Jihyeon
    Park, Sehwan
    Cho, Soo Gyeong
    Goh, Eun Mee
    Lee, Sungman
    Koh, Sung-Suk
    Kim, Jeongkwon
    TALANTA, 2014, 120 : 64 - 70
  • [22] A Simple Analytical Model for Predicting the Detectable Ion Current in Ion Mobility Spectrometry Using Corona Discharge Ionization Sources
    Kirk, Ansgar Thomas
    Kobelt, Tim
    Spehlbrink, Hauke
    Zimmermann, Stefan
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2018, 29 (07) : 1425 - 1430
  • [23] Direct detection of glyphosate in drinking water using corona-discharge ion mobility spectrometry: A theoretical and experimental study
    Khademi, Seyed Mohammad Seyed
    Telgheder, Ursula
    Valadbeigi, Younes
    Ilbeigi, Vahideh
    Tabrizchi, Mahmoud
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2019, 442 : 29 - 34
  • [24] Direct determination of ammoniacal nitrogen in water samples using corona discharge ion mobility spectrometry
    Jafari, M. T.
    Khayamian, T.
    TALANTA, 2008, 76 (05) : 1189 - 1193
  • [25] Separation of sarcosine and L-alanine isomers using corona discharge ion mobility spectrometry
    Shiva Mirmahdieh
    Taghi Khayamian
    Journal of Analytical Chemistry, 2014, 69 : 513 - 518
  • [26] Separation of sarcosine and L-alanine isomers using corona discharge ion mobility spectrometry
    Mirmahdieh, Shiva
    Khayamian, Taghi
    JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 69 (06) : 513 - 518
  • [27] Determination of Malathion Using Corona Discharge - Ion Mobility Spectrometry with Solid-Phase Microextraction
    Mu, Ren
    He, Xiuli
    Gao, Xiaoguang
    Jia, Jian
    Li, Jianping
    ANALYTICAL LETTERS, 2018, 51 (06) : 807 - 819
  • [28] Performance evaluation of oxygen adsorbents using negative corona discharge-ion mobility spectrometry
    Azadkish, Kamal
    Jafari, Mohammad T.
    Ghaziaskar, Hassan S.
    ANALYTICA CHIMICA ACTA, 2017, 953 : 32 - 39
  • [29] Determination of veterinary drug residues in chicken meat using corona discharge ion mobility spectrometry
    Jafari, M. T.
    Khayamian, T.
    Shaer, V.
    Zarei, N.
    ANALYTICA CHIMICA ACTA, 2007, 581 (01) : 147 - 153