Thermionic sodium ion source versus corona discharge in detection of alkaloids using ion mobility spectrometry

被引:4
|
作者
Asadi, Masood [1 ]
Valadbeigi, Younes [2 ]
Tabrizchi, Mahmoud [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
[2] Imam Khomeini Int Univ, Fac Sci, Dept Chem, POB 288, Qazvin, Iran
关键词
Thermal ionization; Ion mobility spectrometry; Sodium ion; Alkaloids; Ionization source; IONIZATION SOURCE;
D O I
10.1007/s12127-019-00249-9
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
IMS spectra obtained by using a thermal ionization sodium ion (SI) source and a corona discharge (CD) source were compared in terms of resolution, selectivity and sensitivity. The reactant ion peak (RIP) for the SI source is a single narrow peak which appears in a shorter drift time compared to the main RIP of the CD ion source, (H2O)(n)H3O+. Comparison of the IMS spectra of selected alkaloids obtained with both the CD and the SI sources shows that the latter exhibits simpler pattern, including a narrow single peak for each compound, well separated from other samples peak. Furthermore, the product ion peaks (PIP) in the SI source appeared at higher drift times leading to higher peak-to-peak resolution. However, the sodium ion source is less sensitive to the selected alkaloids compared to the CD ion source.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 50 条
  • [41] Simultaneous analysis of bifenthrin and tetramethrin using corona discharge ion mobility spectrometry and Tucker 3 model
    Khayamian, T.
    Sajjadi, S. M.
    Mirmahdieh, Sh.
    Mardihallaj, A.
    Hashemian, Z.
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2012, 118 : 88 - 96
  • [42] Quantitative analysis of morphine and noscapine using corona discharge ion mobility spectrometry with ammonia reagent gas
    Khayamian, T.
    Tabrizchi, M.
    Jafari, M. T.
    TALANTA, 2006, 69 (04) : 795 - 799
  • [43] Ultrasonic Piezoelectric Nebulization of Propoxur for the Determination by Corona Discharge Ionization Ion Mobility Spectrometry
    Alireza Tabibi
    Mohammad T. Jafari
    Analytical Sciences, 2020, 36 : 227 - 231
  • [44] Ultrasonic Piezoelectric Nebulization of Propoxur for the Determination by Corona Discharge Ionization Ion Mobility Spectrometry
    Tabibi, Alireza
    Jafari, Mohammad T.
    ANALYTICAL SCIENCES, 2020, 36 (02) : 227 - 232
  • [45] An NO+ reactant ion source for ion mobility spectrometry
    Darzi, Maedeh
    Tabrizchi, Mahmoud
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2013, 16 (04) : 275 - 280
  • [46] Development of Unidirectional Negative Corona Discharge Ion Mobility Spectrometer for Detection of Explosives
    Liu Ji-Wei
    Peng Li-Ying
    Huang Wei
    Wang Wei-Guo
    Jiang Dan-Dan
    Sun Qi
    Li Hai-Yang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (08) : 1185 - 1192
  • [47] The study of thermal decomposition of RDX by corona discharge-ion mobility spectrometry-mass spectrometry
    Lichvanova, Zuzana
    Sabo, Martin
    Matejcik, Stefan
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2015, 18 (1-2) : 59 - 66
  • [48] Combined secondary electrospray and corona discharge ionization (SECDI) for improved detection of explosive vapors using drift tube ion mobility spectrometry
    Mullen, Matthew
    Giordano, Braden C.
    TALANTA, 2020, 209
  • [49] Investigation of corona discharge ionization of barbituric acid using ion mobility spectrometry along with quantum chemical calculations
    Ghahremani, Masoumeh
    Salehabadi, Hafezeh
    Bahrami, Hamed
    Amanlou, Massoud
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2021, 27 (01) : 39 - 47
  • [50] Detection of explosives in hair using ion mobility spectrometry
    Oxley, Jimmie C.
    Smith, James L.
    Kirschenbaum, Louis J.
    Marimganti, Suvarna
    Vadlamannati, Sravanthi
    JOURNAL OF FORENSIC SCIENCES, 2008, 53 (03) : 690 - 693