In this work, thermal decomposition has been used to detect explosives by IMS in positive polarity. Explosives including Pentaerythritol Tetra nitrate (PETN), Cyclo-1,3,5-Trimethylene-2,4,6-Trinitramine (RDX), 2,4,6-Trinitrotoluene (TNT), 2,4-Dihydro-5-nitro-3H-1,2,4-triazol-3-one (NTO), 1,3,5.7-Tetranitro-1,3,5,7-tetrazocine (HMX), have been evaluated at temperatures between 150 and 250 degrees C in positive polarity in air. Explosives yield NOx which causes NO+ peak to increase. Additional peaks may be used to identify the type of explosive. The limit of detection for RDX, HMX, PETN, NTO, and TNT were obtained to be 1, 10, 40, 1000, and 1000 ng, respectively. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:692 / 696
页数:5
相关论文
共 50 条
  • [1] Laser desorption with corona discharge ion mobility spectrometry for direct surface detection of explosives
    Sabo, M.
    Malaskova, M.
    Matejcik, S.
    ANALYST, 2014, 139 (20) : 5112 - 5117
  • [2] Development of Unidirectional Negative Corona Discharge Ion Mobility Spectrometer for Detection of Explosives
    Liu Ji-Wei
    Peng Li-Ying
    Huang Wei
    Wang Wei-Guo
    Jiang Dan-Dan
    Sun Qi
    Li Hai-Yang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (08) : 1185 - 1192
  • [3] Analysis of explosives using corona discharge ionization combined with ion mobility spectrometry-mass spectrometry
    Lee, Jihyeon
    Park, Sehwan
    Cho, Soo Gyeong
    Goh, Eun Mee
    Lee, Sungman
    Koh, Sung-Suk
    Kim, Jeongkwon
    TALANTA, 2014, 120 : 64 - 70
  • [4] Detection of explosives by ion mobility spectrometry
    Buryakov, I. A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (08) : 674 - 694
  • [5] Detection of explosives by ion mobility spectrometry
    I. A. Buryakov
    Journal of Analytical Chemistry, 2011, 66 : 674 - 694
  • [6] ION MOBILITY MEASUREMENTS IN A POSITIVE CORONA DISCHARGE
    STEARNS, RG
    JOURNAL OF APPLIED PHYSICS, 1990, 67 (06) : 2789 - 2799
  • [7] False Positive Signals in the Detection of Explosives by Ion Mobility Spectrometry: Organic Acids
    Buryakov, T. I.
    Buryakov, I. A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 79 (04) : 430 - 439
  • [8] DETECTION OF TOLUENE, METHANOL AND FORMALDEHYDE USING CORONA DISCHARGE ION MOBILITY SPECTROMETRY
    Li, Shu
    Jia, Jian
    Gao, Xiaoguang
    He, Xiuli
    Li, Jianping
    ANALYTICAL LETTERS, 2012, 45 (08) : 841 - 849
  • [9] Corona discharge ion mobility spectrometry at reduced pressures
    Tabrizchi, M
    Rouholahnejad, F
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (11): : 4656 - 4661
  • [10] Corona Discharge Ion Mobility Spectrometry of Ten Alcohols
    Han, Hai-yan
    Wang, Hong-mei
    Jiang, Hai-he
    Stano, Michal
    Sabo, Martin
    Matejcik, Stefan
    Chu, Yan-nan
    CHINESE JOURNAL OF CHEMICAL PHYSICS, 2009, 22 (06) : 605 - 610