Optimization of the sample preparation and measurement protocol for the analysis of uranium isotopes by MC-ICP-MS without spike addition

被引:14
|
作者
Rovan, Leja [1 ,2 ]
Strok, Marko [1 ,2 ]
机构
[1] Jozef Stefan Inst, Dept Environm Sci, Jamova 39, SI-1000 Ljubljana, Slovenia
[2] Jozef Stefan Int Postgrad Sch, Jamova 39, SI-1000 Ljubljana, Slovenia
关键词
RATIO MEASUREMENTS; MASS-SPECTROMETRY; FRACTIONATION; THORIUM; SEPARATION; U-236; U-234/U-238; PRECISION; YIELDS; WATER;
D O I
10.1039/c9ja00144a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study quantifies the behaviour of uranium isotope ratios (U-235/U-238 and U-234/U-238) with different aqueous sample preparation and separation techniques using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) measurements and optimization of the MC-ICP-MS measurement protocol to obtain high precision and accuracy for uranium isotope ratios. The obtained results were compared with reference values, and they show that different sample preparation and separation methods influence the uranium isotopic composition and consequently the final results of unknown samples. The analytical procedure with the highest achievable precision and accuracy for uranium isotopes was the combination of coprecipitation with Ca-3(PO4)(2) and extraction chromatography with precleaned UTEVA resins. The combination of coprecipitation with Fe(OH)(3) and ion exchange chromatography (DOWEX resins) provided the lowest achievable accuracy for uranium isotopes. The results reveal the extent of uranium biases during different physicochemical processing of samples in the range of -254 to 2.60 parts per thousand for U-235/U-238 and -299 to 8.90 parts per thousand for U-234/U-238. A combination of sample preparation and measurement protocol optimization is of importance for various applications requiring extensive sample pre-treatment procedures where the U-233/U-236 double spike method for correcting for mass bias during sample preparation and separation steps is not feasible and to establish a methodology which enables the accurate determination of uranium isotope ratios in low-level concentration samples.
引用
收藏
页码:1882 / 1891
页数:10
相关论文
共 50 条
  • [31] Precise/small sample size determination of stable Cd isotope ratios of geological samples with double spike MC-ICP-MS
    Guo, Chao
    Li, Tao
    Li, Gaojun
    Chen, Tianyu
    Li, Le
    Zhao, Liang
    Ji, Junfeng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (11) : 2470 - 2479
  • [32] Titanium Isotope Analysis of Igneous Reference Materials using a Double-spike MC-ICP-MS Method
    LI Jin
    TANG Suohan
    ZHU Xiangkun
    MA Jianxiong
    ZHAO Xinmiao
    ActaGeologicaSinica(EnglishEdition), 2022, 96 (02) : 517 - 524
  • [33] High-precision double-spike Sn isotope analysis of geological materials by MC-ICP-MS
    She, Jia-Xin
    Li, Weiqiang
    An, Shichao
    Cai, Yuanfeng
    Journal of Analytical Atomic Spectrometry, 2022,
  • [34] High-precision measurement of Cd isotopes in ultra-trace Cd samples using double spike-standard addition MC-ICP-MS (vol 38, pg 950, 2023)
    Chang, Hui
    Zhu, Jian-Ming
    Wang, Xiangli
    Gao, Ting
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (04) : 1175 - 1175
  • [35] Development of an isolation procedure and MC-ICP-MS measurement protocol for the study of stable isotope ratio variations of nickel
    Chernonozhkin, Stepan M.
    Goderis, Steven
    Lobo, Lara
    Claeys, Philippe
    Vanhaecke, Frank
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (07) : 1518 - 1530
  • [36] Preparation of standards for in situ sulfur isotope measurement in sulfides using femtosecond laser ablation MC-ICP-MS
    Chen, Lu
    Chen, Kaiyun
    Bao, Zhian
    Liang, Peng
    Sun, Tiantian
    Yuan, Honglin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (01) : 107 - 116
  • [37] Mass-independent fractionation during Mo isotope measurement by MC-ICP-MS: implications for application of the double spike technique
    Zhao, Yan
    Yang, Wubin
    Leng, Chengbiao
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (04) : 785 - 791
  • [38] A Systematic Investigation of the Effects of Standard-Sample Concentration Mismatch during Fe Isotope Measurement by MC-ICP-MS
    King-Doonan, Elizabeth K.
    Bilenker, Laura D.
    Weis, Dominque
    Gordon, Kathy
    Fourny, Anais
    Patton, Genna M.
    Zhao, Ye
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2024, 48 (02) : 309 - 330
  • [39] Accurate Measurement of Mg Isotopes in Twenty-four Reference Materials by MC-ICP-MS with A Highly Efficient Optimized Method
    Yang, Ao
    Lin, Jie
    Zhang, Tiantian
    Zhu, Xi
    Lin, Ran
    Deng, Kexin
    Liu, Zhenyi
    Hu, Zhaochu
    Liu, Yongsheng
    ATOMIC SPECTROSCOPY, 2023, 44 (05) : 365 - 374
  • [40] High-precision analysis of calcium isotopes using a Nu Sapphire collision cell (CC)-MC-ICP-MS
    Gao, Bing-Yu
    Su, Ben-Xun
    Li, Wen-Jun
    Yuan, Meng
    Sun, Jian
    Zhao, Ye
    Liu, Xia
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (10) : 2111 - 2121