This study quantifies the behaviour of uranium isotope ratios (U-235/U-238 and U-234/U-238) with different aqueous sample preparation and separation techniques using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) measurements and optimization of the MC-ICP-MS measurement protocol to obtain high precision and accuracy for uranium isotope ratios. The obtained results were compared with reference values, and they show that different sample preparation and separation methods influence the uranium isotopic composition and consequently the final results of unknown samples. The analytical procedure with the highest achievable precision and accuracy for uranium isotopes was the combination of coprecipitation with Ca-3(PO4)(2) and extraction chromatography with precleaned UTEVA resins. The combination of coprecipitation with Fe(OH)(3) and ion exchange chromatography (DOWEX resins) provided the lowest achievable accuracy for uranium isotopes. The results reveal the extent of uranium biases during different physicochemical processing of samples in the range of -254 to 2.60 parts per thousand for U-235/U-238 and -299 to 8.90 parts per thousand for U-234/U-238. A combination of sample preparation and measurement protocol optimization is of importance for various applications requiring extensive sample pre-treatment procedures where the U-233/U-236 double spike method for correcting for mass bias during sample preparation and separation steps is not feasible and to establish a methodology which enables the accurate determination of uranium isotope ratios in low-level concentration samples.
引用
收藏
页码:1882 / 1891
页数:10
相关论文
共 50 条
  • [41] Direct measurement of Cu and Pb isotopic ratios without column chemistry for bronze materials using MC-ICP-MS
    Bao, Zhian
    Zong, Chunlei
    Liang, Peng
    Zhang, Yan
    Chen, Kaiyun
    Yuan, Honglin
    ANALYTICAL METHODS, 2020, 12 (20) : 2599 - 2607
  • [42] Achieving rapid analysis of Li isotopes in high-matrix and low-Li samples with MC-ICP-MS: new developments in sample preparation and mass bias behavior of Li in ICPMS
    Zhu, Zhi-Yong
    Yang, Tao
    Zhu, Xiang-Kun
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (07) : 1503 - 1513
  • [43] Direct determination (without chromatographic separation) of lithium isotopes in saline fluids using MC-ICP-MS: establishing limits on water chemistry
    Macpherson, G. L.
    Phan, Thai T.
    Stewart, Brian W.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (07) : 1673 - 1678
  • [44] Determining Ba isotopes of barite using the Na2CO3 exchange reaction and double-spike method by MC-ICP-MS
    Tian, Lan-Lan
    Zeng, Zhen
    Nan, Xiao-Yun
    Yu, Hui-Min
    Huang, Fang
    Journal of Analytical Atomic Spectrometry, 2019, 34 (07): : 1459 - 1467
  • [45] Determining Ba isotopes of barite using the Na2CO3 exchange reaction and double-spike method by MC-ICP-MS
    Tian, Lan-Lan
    Zeng, Zhen
    Nan, Xiao-Yun
    Yu, Hui-Min
    Huang, Fang
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (07) : 1459 - 1467
  • [46] An optimized protocol for high precision measurement of Hg isotopic compositions in samples with low concentrations of Hg using MC-ICP-MS
    Geng, Hongyan
    Yin, Runsheng
    Li, Xiangdong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (11) : 1932 - 1940
  • [47] Precise measurement of Fe isotopes in marine samples by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    de Jong, Jeroen
    Schoemann, Veronique
    Tison, Jean-Louis
    Becquevort, Sylvie
    Masson, Florence
    Lannuzel, Delphine
    Petit, Jerome
    Chou, Lei
    Weis, Dominique
    Mattielli, Nadine
    ANALYTICA CHIMICA ACTA, 2007, 589 (01) : 105 - 119
  • [48] High-precision analysis of potassium isotopes by MC-ICP-MS without collision cell using cool plasma technique in low-resolution mode
    Gu, Hai-Ou
    Sun, He
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (11) : 2545 - 2552
  • [49] Direct measurement of Fe isotope compositions in iron-dominated minerals without column chromatography using MC-ICP-MS
    Chen, Kaiyun
    Bao, Zhian
    Yuan, Honglin
    Lv, Nan
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (02) : 249 - 263
  • [50] High throughput uranium isotope ratio analysis using MC-ICP-MS: Techniques to improve the mass bias stability.
    Bowen, IM
    Miller, P
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 220 : U7 - U8