Optimization of the sample preparation and measurement protocol for the analysis of uranium isotopes by MC-ICP-MS without spike addition

被引:14
|
作者
Rovan, Leja [1 ,2 ]
Strok, Marko [1 ,2 ]
机构
[1] Jozef Stefan Inst, Dept Environm Sci, Jamova 39, SI-1000 Ljubljana, Slovenia
[2] Jozef Stefan Int Postgrad Sch, Jamova 39, SI-1000 Ljubljana, Slovenia
关键词
RATIO MEASUREMENTS; MASS-SPECTROMETRY; FRACTIONATION; THORIUM; SEPARATION; U-236; U-234/U-238; PRECISION; YIELDS; WATER;
D O I
10.1039/c9ja00144a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study quantifies the behaviour of uranium isotope ratios (U-235/U-238 and U-234/U-238) with different aqueous sample preparation and separation techniques using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) measurements and optimization of the MC-ICP-MS measurement protocol to obtain high precision and accuracy for uranium isotope ratios. The obtained results were compared with reference values, and they show that different sample preparation and separation methods influence the uranium isotopic composition and consequently the final results of unknown samples. The analytical procedure with the highest achievable precision and accuracy for uranium isotopes was the combination of coprecipitation with Ca-3(PO4)(2) and extraction chromatography with precleaned UTEVA resins. The combination of coprecipitation with Fe(OH)(3) and ion exchange chromatography (DOWEX resins) provided the lowest achievable accuracy for uranium isotopes. The results reveal the extent of uranium biases during different physicochemical processing of samples in the range of -254 to 2.60 parts per thousand for U-235/U-238 and -299 to 8.90 parts per thousand for U-234/U-238. A combination of sample preparation and measurement protocol optimization is of importance for various applications requiring extensive sample pre-treatment procedures where the U-233/U-236 double spike method for correcting for mass bias during sample preparation and separation steps is not feasible and to establish a methodology which enables the accurate determination of uranium isotope ratios in low-level concentration samples.
引用
收藏
页码:1882 / 1891
页数:10
相关论文
共 50 条
  • [21] Accurate and high-precision measurement of lithium isotopes in two reference materials by MC-ICP-MS
    Millot, R
    Guerrot, C
    Vigier, N
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2004, 28 (01) : 153 - 159
  • [22] Exploration of metallic interferences pertinent to nuclear safeguards related uranium isotope ratio measurement on the Neoma MC-ICP-MS platform without the MS/MS option
    Zirakparvar, N. Alex
    Manard, Benjamin T.
    Dunlap, Daniel R.
    Ticknor, Brian
    Darnell, Matt
    Metzger, Shalina C.
    Hexel, Cole R.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2024, 503
  • [23] High precision Uranium isotope analysis in urine by MC-ICP-MS and the detection of historic exposure to depleted Uranium
    Parrish, R. R.
    Horstwood, M. S. A.
    Lloyd, N.
    Arnason, J. G.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2008, 72 (12) : A724 - A724
  • [24] Accurate Measurement of Chromium Isotopic Compositions in Geological Reference Materials by Double-Spike MC-ICP-MS
    Shi, Kai
    Wu, Guangliang
    Zhu, Jian-Ming
    Wang, Xiangli
    ATOMIC SPECTROSCOPY, 2021, 42 (03) : 128 - 133
  • [25] High-Precision Sn Isotopic Measurement in Geological Materials by Double-Spike MC-ICP-MS
    Song, Wenrui
    Zhu, Chuanwei
    Wen, Hanjie
    Zhang, Yuxu
    Liu, Zerui
    Zhou, Meifu
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2024,
  • [26] High precision cadmium isotope analysis of geological reference materials by double spike MC-ICP-MS
    Peng, Huan
    He, Dong
    Guo, Rui
    Liu, Xing
    Belshaw, Nicholas S.
    Zheng, Hongtao
    Hu, Shenghong
    Zhu, Zhenli
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (02) : 390 - 398
  • [27] High-sensitivity determination of Cd isotopes in low-Cd geological samples by double spike MC-ICP-MS
    Tan, Decan
    Zhu, Jian-Ming
    Wang, Xiangli
    Han, Guilin
    Lu, Zhuo
    Xu, Wenpo
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (04) : 713 - 727
  • [28] Iron isotopes in natural carbonate minerals determined by MC-ICP-MS with a 58Fe-54Fe double spike
    Dideriksen, K
    Baker, JA
    Stipp, SLS
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2006, 70 (01) : 118 - 132
  • [29] High-precision double-spike Sn isotope analysis of geological materials by MC-ICP-MS
    She, Jia-Xin
    Li, Weiqiang
    An, Shichao
    Cai, Yuanfeng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (01) : 142 - 155
  • [30] Titanium Isotope Analysis of Igneous Reference Materials using a Double-spike MC-ICP-MS Method
    Li, Jin
    Tang, Suohan
    Zhu, Xiangkun
    Ma, Jianxiong
    Zhao, Xinmiao
    ACTA GEOLOGICA SINICA-ENGLISH EDITION, 2022, 96 (02) : 517 - 524