A Systematic Investigation of the Effects of Standard-Sample Concentration Mismatch during Fe Isotope Measurement by MC-ICP-MS

被引:3
|
作者
King-Doonan, Elizabeth K. [1 ,2 ]
Bilenker, Laura D. [1 ,3 ]
Weis, Dominque [1 ]
Gordon, Kathy [1 ]
Fourny, Anais [1 ,5 ]
Patton, Genna M. [1 ,6 ]
Zhao, Ye [4 ]
机构
[1] Univ British Columbia, Pacific Ctr Isotop & Geochem Res, Dept Earth Ocean & Atmospher Sci, Multidisciplinary Appl Geochem Network, Vancouver, BC V6T 1Z4, Canada
[2] DEVCOM ARL, Army Res Off, Durham, NC 27709 USA
[3] Auburn Univ, Dept Geosci, Coll Sci & Math, Auburn, AL 36849 USA
[4] Nu Instrument Ltd, 74 Clywedog Rd South, Wrexham LL13 9XS, Wales
[5] Canadian Nucl Labs, Chalk River, ON K0J 1J0, Canada
[6] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
基金
加拿大自然科学与工程研究理事会;
关键词
iron isotopes; non-traditional stable isotope; geochemistry; mass spectrometry; correction method; standard-sample bracketing; RATIO MEASUREMENTS; MASS-SPECTROMETRY; DOUBLE SPIKE; IRON; FRACTIONATION; PRECISE; CONSTRAINTS; COPPER; BIAS; INTERFERENCES;
D O I
10.1111/ggr.12541
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Advances in multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) have led to the widespread use of iron (Fe) isotopes to elucidate the (bio)geochemical history of a range of environments. To generate Fe isotope ratio measurements, standard-sample bracketing (SSB) is commonly used to correct for instrumental mass bias inherent to MC-ICP-MS. However, SSB is only accurate when sample and isotope standard Fe concentrations match, in addition to the bulk solution matrix. When the Fe concentrations differ, Fe isotope ratio measurement results may be inaccurate, a phenomenon known as the "self-induced matrix effect." This study systematically characterised the self-induced matrix effect for dry plasma Fe isotope ratio measurements on three MC-ICP-MS instruments and three introduction systems. Our extensive dataset indicates that: (1) the degree of mass bias is consistent regardless of MC-ICP-MS front-end design, (2) the degree of mass bias becomes less reproducible as the concentration difference between the sample and bracketing standard increases, and (3) this applies to both pure Fe solutions and solutions from geological materials. This study reinforces the requirement to match bracketing standard and sample concentrations within 10% and provides a correction method for that fall beyond the recommended concentration range to subsequently allow for proper concentration matching during SSB.
引用
收藏
页码:309 / 330
页数:22
相关论文
共 50 条
  • [1] Vanadium isotope measurement by MC-ICP-MS
    Wu, Fei
    Qi, Yuhan
    Yu, Huimin
    Tian, Shengyu
    Hou, Zhenhui
    Huang, Fang
    CHEMICAL GEOLOGY, 2016, 421 : 17 - 25
  • [2] Plutonium and uranium isotope ratio measurement by MC-ICP-MS
    Taylor, RN
    Warneke, T
    Croudace, IW
    Milton, JA
    Warwick, PE
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2002, 66 (15A) : A766 - A766
  • [3] Measurement of isotope ratios on transient signals by MC-ICP-MS
    Günther-Leopold, I
    Wernli, B
    Kopajtic, Z
    Günther, D
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (02) : 241 - 249
  • [4] Measurement of U/Th Isotopic Compositions in Stalagmites for 230Th/U Geochronology Using MC-ICP-MS by Standard-Sample Bracketing Method
    Liao Z.-B.
    Shao Q.-F.
    Li C.-H.
    Kong X.-G.
    Wang Y.-J.
    Shao, Qing-Feng (qingfengshao@njnu.edu.cn), 2018, Chinese Society for Mass Spectrometry (39) : 295 - 309
  • [5] Evaluation of the combined measurement uncertainty in isotope dilution by MC-ICP-MS
    G. Fortunato
    S. Wunderli
    Analytical and Bioanalytical Chemistry, 2003, 377 : 111 - 116
  • [6] Evaluation of the combined measurement uncertainty in isotope dilution by MC-ICP-MS
    Fortunato, G
    Wunderli, S
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (01) : 111 - 116
  • [7] Silicon Isotope Measurement of Giant Diatoms Using MC-ICP-MS
    Choi, Ah Yeong
    Ryu, Jong-Sik
    Hyeong, Kiseong
    Kim, Mun Gi
    Ra, Kongtae
    Jeong, Hyeryeong
    Lim, Hyoun Soo
    JOURNAL OF THE KOREAN EARTH SCIENCE SOCIETY, 2021, 42 (01): : 1 - 10
  • [8] Experimental investigation of improved tolerance for concentration mismatch in potassium isotope analysis on a hexapole collision cell MC-ICP-MS (Nu Sapphire)
    Li, Wenjun
    Zhao, Ye
    Su, Benxun
    Gao, Bingyu
    Wang, Jing
    Liu, Shanke
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (03) : 603 - 608
  • [9] Zinc Isotope Measurement by MC-ICP-MS in Geological Certified Reference Materials
    Wang, Jing
    Tang, Dong-Mei
    Yuan, Qing-Han
    Su, Ben-Xun
    Li, Wen-Jun
    Gao, Bing-Yu
    Bao, Zhi-An
    Zhao, Ye
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2023, 47 (04) : 969 - 982
  • [10] Isotope fractionation during microbial metal uptake measured by MC-ICP-MS
    Wasylenki, L. E.
    Anbar, A. D.
    Liermann, L. J.
    Mathur, R.
    Gordon, G. W.
    Brantley, S. L.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (08) : 905 - 910