Radiation dose and image quality in intraoperative CT (iCT) angiography of the brain with stereotactic head frames

被引:1
|
作者
Forbrig, Robert [1 ]
Geyer, Lucas L. [2 ]
Stahl, Robert [3 ]
Thorsteinsdottir, Jun [4 ]
Schichor, Christian [4 ]
Kreth, Friedrich-Wilhelm [4 ]
Patzig, Maximilian [1 ]
Herzberg, Moriz [1 ]
Liebig, Thomas [1 ]
Dorn, Franziska [1 ]
Trumm, Christoph G. [5 ]
机构
[1] Ludwig Maximilians Univ Munchen, Univ Hosp, Inst Neuroradiol, Marchioninistr 15, D-81377 Munich, Germany
[2] Klinikum Ingolstadt, Ctr Radiol & Neuroradiol, Ingolstadt, Germany
[3] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Radiol, Munich, Germany
[4] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Neurosurg, Munich, Germany
[5] Stadt Klinikum Munchen Harlaching, Inst Diagnost & Intervent Radiol Neuroradiol & Nu, Munich, Germany
关键词
Brain; Radiation dosage; Neuronavigation; Computed tomography angiography; METAL ARTIFACT REDUCTION; ENERGY COMPUTED-TOMOGRAPHY; TUBE CURRENT MODULATION; 70; KVP; ITERATIVE RECONSTRUCTION; CONTRAST MATERIAL; BIOPSY; FEASIBILITY; MULTISLICE; VOLTAGE;
D O I
10.1007/s00330-018-5930-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesIntraoperative CT (iCT) angiography of the brain with stereotactic frames is an integral part of navigated neurosurgery. Validated data regarding radiation dose and image quality in these special examinations are not available. We therefore investigated two iCT protocols in this IRB-approved study.MethodsRetrospective analysis of patients, who received a cerebral stereotactic iCT angiography on a 128 slice CT scanner between February 2016 and December 2017. In group A, automated tube current modulation (ATCM; reference value 410mAs) and automated tube voltage selection (reference value 120kV) were enabled, and only examinations with a selected voltage of 120kV were included. In group B, fixed parameters were applied (300mAs, 120kV). Radiation dose was measured by assessing the volumetric CT dose index (CTDIvol), dose length product (DLP) and effective dose (ED). Signal-to-noise ratio (SNR) and image noise were assessed for objective image quality, visibility of arteries and grey-white differentiation for subjective image quality.ResultsTwo hundred patients (n=100 in each group) were included. In group A, median selected tube current was 643mAs (group B, 300mAs; p<0.001). Median values of CTDIvol, DLP and ED were 91.54mGy, 1561mGycm and 2.97mSv in group A, and 43.15mGy, 769mGycm and 1.46mSv in group B (p<0.001). Image quality did not significantly differ between groups (p>0.05).ConclusionsATCM yielded disproportionally high radiation dose due to substantial tube current increase at the frame level, while image quality did not improve. Thus, ATCM should preferentially be disabled.Key Points center dot Automated tube current modulation (ATCM) yields disproportionally high radiation dose in intraoperative CT angiography of the brain with stereotactic head frames.center dot ATCM does not improve overall image quality in these special examinations.center dot ATCM is not yet optimised for CT angiography of the brain with major extracorporeal foreign materials within the scan range.
引用
收藏
页码:2859 / 2867
页数:9
相关论文
共 50 条
  • [41] CT protocols: balancing radiation dose and image quality
    Richard Fotter
    Pediatric Radiology, 2011, 41 : 215 - 216
  • [42] CT protocols: balancing radiation dose and image quality
    Fotter, Richard
    PEDIATRIC RADIOLOGY, 2011, 41 : S215 - S216
  • [43] CT Image Quality and Radiation Dose Survey in Taiwan
    Tsai, H. Y.
    Liu, H. L.
    Chen, C. C.
    Hwang, Y. S.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [44] Image quality/radiation dose considerations in pediatric CT
    Hernanz-Schulman, M
    Reese, M
    Price, RR
    Stein, SM
    Heller, RM
    Holburn, GE
    Stabin, MG
    RADIOLOGY, 2001, 221 : 246 - 246
  • [45] Assessment of image quality and dose in contrast-enhanced head and neck CT angiography of New Zealand rabbit
    Hsiao, Chia-Chi
    Chen, Po-Chou
    Kuo, Pei-Chi
    Ho, Chih-Hao
    Jao, Jo-Chi
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2020, 28 (04) : 739 - 750
  • [46] CT Angiography of the Head-and-Neck Vessels Acquired with Low Tube Voltage, Low Iodine, and Iterative Image Reconstruction: Clinical Evaluation of Radiation Dose and Image Quality
    Zhang, Wei-lan
    Li, Min
    Zhang, Bo
    Geng, Hai-yang
    Liang, Yin-qiang
    Xu, Ke
    Li, Song-bai
    PLOS ONE, 2013, 8 (12):
  • [47] Adaptive Iterative Dose Reduction in coronary CT angiography using 320-row CT: Assessment of radiation dose reduction and image quality
    Tomizawa, Nobuo
    Nojo, Takeshi
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (05) : 318 - 324
  • [48] Dose and Image Quality in C-Arm CT Rotational Angiography
    Fahrig, R.
    Girard-Hughes, E.
    Ganguly, A.
    Tognolini, A.
    Kothary, N.
    MEDICAL PHYSICS, 2010, 37 (06) : 3413 - 3414
  • [49] Low-dose CT angiography of the abdominal aorta and reduced contrast medium volume: Assessment of image quality and radiation dose
    Nijhof, W. H.
    Baltussen, E. J. M.
    Kant, I. M. J.
    Jager, G. J.
    Slump, C. H.
    Rutten, M. J. C. M.
    CLINICAL RADIOLOGY, 2016, 71 (01) : 64 - 73
  • [50] Image Quality in Computed Tomography Coronary Angiography and Radiation Dose Reduction
    Golubickas, Domas
    Lukosevicius, Saulius
    Tamakauskas, Vytenis
    Dobrovolskiene, Laima
    Baseviciene, Ingrida
    Grib, Liviu
    Ragaisyte, Nijole
    Leonavicius, Rytis
    Medvedev, Viktor
    Veikutis, Vincentas
    INFORMATICA, 2021, 32 (04) : 741 - 757