Radiation dose and image quality in intraoperative CT (iCT) angiography of the brain with stereotactic head frames

被引:1
|
作者
Forbrig, Robert [1 ]
Geyer, Lucas L. [2 ]
Stahl, Robert [3 ]
Thorsteinsdottir, Jun [4 ]
Schichor, Christian [4 ]
Kreth, Friedrich-Wilhelm [4 ]
Patzig, Maximilian [1 ]
Herzberg, Moriz [1 ]
Liebig, Thomas [1 ]
Dorn, Franziska [1 ]
Trumm, Christoph G. [5 ]
机构
[1] Ludwig Maximilians Univ Munchen, Univ Hosp, Inst Neuroradiol, Marchioninistr 15, D-81377 Munich, Germany
[2] Klinikum Ingolstadt, Ctr Radiol & Neuroradiol, Ingolstadt, Germany
[3] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Radiol, Munich, Germany
[4] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Neurosurg, Munich, Germany
[5] Stadt Klinikum Munchen Harlaching, Inst Diagnost & Intervent Radiol Neuroradiol & Nu, Munich, Germany
关键词
Brain; Radiation dosage; Neuronavigation; Computed tomography angiography; METAL ARTIFACT REDUCTION; ENERGY COMPUTED-TOMOGRAPHY; TUBE CURRENT MODULATION; 70; KVP; ITERATIVE RECONSTRUCTION; CONTRAST MATERIAL; BIOPSY; FEASIBILITY; MULTISLICE; VOLTAGE;
D O I
10.1007/s00330-018-5930-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesIntraoperative CT (iCT) angiography of the brain with stereotactic frames is an integral part of navigated neurosurgery. Validated data regarding radiation dose and image quality in these special examinations are not available. We therefore investigated two iCT protocols in this IRB-approved study.MethodsRetrospective analysis of patients, who received a cerebral stereotactic iCT angiography on a 128 slice CT scanner between February 2016 and December 2017. In group A, automated tube current modulation (ATCM; reference value 410mAs) and automated tube voltage selection (reference value 120kV) were enabled, and only examinations with a selected voltage of 120kV were included. In group B, fixed parameters were applied (300mAs, 120kV). Radiation dose was measured by assessing the volumetric CT dose index (CTDIvol), dose length product (DLP) and effective dose (ED). Signal-to-noise ratio (SNR) and image noise were assessed for objective image quality, visibility of arteries and grey-white differentiation for subjective image quality.ResultsTwo hundred patients (n=100 in each group) were included. In group A, median selected tube current was 643mAs (group B, 300mAs; p<0.001). Median values of CTDIvol, DLP and ED were 91.54mGy, 1561mGycm and 2.97mSv in group A, and 43.15mGy, 769mGycm and 1.46mSv in group B (p<0.001). Image quality did not significantly differ between groups (p>0.05).ConclusionsATCM yielded disproportionally high radiation dose due to substantial tube current increase at the frame level, while image quality did not improve. Thus, ATCM should preferentially be disabled.Key Points center dot Automated tube current modulation (ATCM) yields disproportionally high radiation dose in intraoperative CT angiography of the brain with stereotactic head frames.center dot ATCM does not improve overall image quality in these special examinations.center dot ATCM is not yet optimised for CT angiography of the brain with major extracorporeal foreign materials within the scan range.
引用
收藏
页码:2859 / 2867
页数:9
相关论文
共 50 条
  • [31] Image Quality in Reduced-Dose Coronary CT Angiography
    Gagarina, Nina V.
    Irwan, Roy
    Gordina, Galina
    Fominykh, Ekaterina
    Sijens, Paul E.
    ACADEMIC RADIOLOGY, 2011, 18 (08) : 984 - 990
  • [32] Head CT: Image quality improvement of posterior fossa and radiation dose reduction with ASiR - comparative studies of CT head examinations
    Guzinski, Maciej
    Waszczuk, Lukasz
    Sasiadek, Marek J.
    EUROPEAN RADIOLOGY, 2016, 26 (10) : 3691 - 3696
  • [33] Head CT: Image quality improvement of posterior fossa and radiation dose reduction with ASiR - comparative studies of CT head examinations
    Maciej Guziński
    Łukasz Waszczuk
    Marek J. Sąsiadek
    European Radiology, 2016, 26 : 3691 - 3696
  • [34] Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose
    Eun-Ah Park
    Whal Lee
    Kwang Woo Kim
    Kwang Gi Kim
    Allmendinger Thomas
    Jin Wook Chung
    Jae Hyung Park
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1775 - 1786
  • [35] Pulmonary CT Angiography as First-Line Imaging for PE: Image Quality and Radiation Dose Considerations
    Mayo, John
    Thakur, Yogesh
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (03) : 522 - 528
  • [36] Cardiovascular CT angiography in neonates and children: Image quality and potential for radiation dose reduction with iterative image reconstruction techniques
    Tricarico, Francesco
    Hlavacek, Anthony M.
    Schoepf, U. Joseph
    Ebersberger, Ullrich
    Nance, John W., Jr.
    Vliegenthart, Rozemarijn
    Cho, Young Jun
    Spears, J. Reid
    Secchi, Francesco
    Savino, Giancarlo
    Marano, Riccardo
    Schoenberg, Stefan O.
    Bonomo, Lorenzo
    Apfaltrer, Paul
    EUROPEAN RADIOLOGY, 2013, 23 (05) : 1306 - 1315
  • [37] Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose
    Park, Eun-Ah
    Lee, Whal
    Kim, Kwang Woo
    Kim, Kwang Gi
    Thomas, Allmendinger
    Chung, Jin Wook
    Park, Jae Hyung
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (07): : 1775 - 1786
  • [38] Radiation dose and diagnostic image quality associated with iterative reconstruction in coronary CT angiography: A systematic review
    Abdullah, Kamarul Amin
    McEntee, Mark F.
    Reed, Warren
    Kench, Peter L.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2016, 60 (04) : 459 - 468
  • [39] Cardiovascular CT angiography in neonates and children: Image quality and potential for radiation dose reduction with iterative image reconstruction techniques
    Francesco Tricarico
    Anthony M. Hlavacek
    U. Joseph Schoepf
    Ullrich Ebersberger
    John W. Nance
    Rozemarijn Vliegenthart
    Young Jun Cho
    J. Reid Spears
    Francesco Secchi
    Giancarlo Savino
    Riccardo Marano
    Stefan O. Schoenberg
    Lorenzo Bonomo
    Paul Apfaltrer
    European Radiology, 2013, 23 : 1306 - 1315
  • [40] Radiation Dose and Image Quality in Pediatric Neck CT
    Tipnis, S. V.
    Rieter, W. J.
    Patel, D.
    Stalcup, S. T.
    Matheus, M. G.
    Spampinato, M. V.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (06) : 1067 - 1073