Radiation dose and image quality in intraoperative CT (iCT) angiography of the brain with stereotactic head frames

被引:1
|
作者
Forbrig, Robert [1 ]
Geyer, Lucas L. [2 ]
Stahl, Robert [3 ]
Thorsteinsdottir, Jun [4 ]
Schichor, Christian [4 ]
Kreth, Friedrich-Wilhelm [4 ]
Patzig, Maximilian [1 ]
Herzberg, Moriz [1 ]
Liebig, Thomas [1 ]
Dorn, Franziska [1 ]
Trumm, Christoph G. [5 ]
机构
[1] Ludwig Maximilians Univ Munchen, Univ Hosp, Inst Neuroradiol, Marchioninistr 15, D-81377 Munich, Germany
[2] Klinikum Ingolstadt, Ctr Radiol & Neuroradiol, Ingolstadt, Germany
[3] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Radiol, Munich, Germany
[4] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Neurosurg, Munich, Germany
[5] Stadt Klinikum Munchen Harlaching, Inst Diagnost & Intervent Radiol Neuroradiol & Nu, Munich, Germany
关键词
Brain; Radiation dosage; Neuronavigation; Computed tomography angiography; METAL ARTIFACT REDUCTION; ENERGY COMPUTED-TOMOGRAPHY; TUBE CURRENT MODULATION; 70; KVP; ITERATIVE RECONSTRUCTION; CONTRAST MATERIAL; BIOPSY; FEASIBILITY; MULTISLICE; VOLTAGE;
D O I
10.1007/s00330-018-5930-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesIntraoperative CT (iCT) angiography of the brain with stereotactic frames is an integral part of navigated neurosurgery. Validated data regarding radiation dose and image quality in these special examinations are not available. We therefore investigated two iCT protocols in this IRB-approved study.MethodsRetrospective analysis of patients, who received a cerebral stereotactic iCT angiography on a 128 slice CT scanner between February 2016 and December 2017. In group A, automated tube current modulation (ATCM; reference value 410mAs) and automated tube voltage selection (reference value 120kV) were enabled, and only examinations with a selected voltage of 120kV were included. In group B, fixed parameters were applied (300mAs, 120kV). Radiation dose was measured by assessing the volumetric CT dose index (CTDIvol), dose length product (DLP) and effective dose (ED). Signal-to-noise ratio (SNR) and image noise were assessed for objective image quality, visibility of arteries and grey-white differentiation for subjective image quality.ResultsTwo hundred patients (n=100 in each group) were included. In group A, median selected tube current was 643mAs (group B, 300mAs; p<0.001). Median values of CTDIvol, DLP and ED were 91.54mGy, 1561mGycm and 2.97mSv in group A, and 43.15mGy, 769mGycm and 1.46mSv in group B (p<0.001). Image quality did not significantly differ between groups (p>0.05).ConclusionsATCM yielded disproportionally high radiation dose due to substantial tube current increase at the frame level, while image quality did not improve. Thus, ATCM should preferentially be disabled.Key Points center dot Automated tube current modulation (ATCM) yields disproportionally high radiation dose in intraoperative CT angiography of the brain with stereotactic head frames.center dot ATCM does not improve overall image quality in these special examinations.center dot ATCM is not yet optimised for CT angiography of the brain with major extracorporeal foreign materials within the scan range.
引用
收藏
页码:2859 / 2867
页数:9
相关论文
共 50 条
  • [21] Radiation Dose and Image Quality at High-Pitch CT Angiography of the Aorta: Intraindividual and Interindividual Comparisons With Conventional CT Angiography
    Apfaltrer, Paul
    Hanna, E. Lexworth
    Schoepf, U. Joseph
    Spears, J. Reid
    Schoenberg, Stefan O.
    Fink, Christian
    Vliegenthart, Rozemarijn
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (06) : 1402 - 1409
  • [22] Tradeoffs in CT image quality and radiation dose
    McNitt-Gray, M
    MEDICAL PHYSICS, 2003, 30 (06) : 1410 - 1410
  • [23] Principles of CT: Radiation Dose and Image Quality
    Goldman, Lee W.
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2007, 35 (04) : 213 - 225
  • [24] Tradeoffs in image quality and radiation dose for CT
    McNitt-Gray, M.
    MEDICAL PHYSICS, 2006, 33 (06) : 2154 - 2155
  • [25] National Survey of Radiation Dose and Image Quality in Adult CT Head Scans in Taiwan
    Lin, Chung-Jung
    Mok, Greta S. P.
    Tsai, Mang-Fen
    Tsai, Wei-Ta
    Yang, Bang-Hung
    Tu, Chun-Yuan
    Wu, Tung-Hsin
    PLOS ONE, 2015, 10 (06):
  • [26] The influence of iterative reconstruction level on image quality and radiation dose in CT pulmonary angiography examinations
    Harun, H.H.
    Karim, M.K.A.
    Abbas, Z.
    Sabarudin, A.
    Muniandy, S.C.
    Razak, H.R.A.
    Ng, K.H.
    Radiation Physics and Chemistry, 2021, 178
  • [27] The influence of iterative reconstruction level on image quality and radiation dose in CT pulmonary angiography examinations
    Harun, H. H.
    Karim, M. K. A.
    Abbas, Z.
    Sabarudin, A.
    Muniandy, S. C.
    Razak, H. R. A.
    Ng, K. H.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 178
  • [28] IMAGE QUALITY AND RADIATION DOSE WITH SINGLE HEART BEAT 320 MULTIDETECTOR CT CORONARY ANGIOGRAPHY
    Williams, M. C.
    Weir, N. W.
    Mirsadraee, S.
    Scott, A. E.
    Uren, N. G.
    McKillop, G.
    Bull, R. K.
    van Beek, E. J. R.
    Reid, J. H.
    Newby, D. E.
    HEART, 2013, 99
  • [29] Image Quality and Radiation Dose of Pulmonary CT Angiography Performed Using 100 and 120 kVp
    Fanous, Randy
    Kashani, Hany
    Jimenez, Laura
    Murphy, Grainne
    Paul, Narinder S.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : 990 - 996
  • [30] CORONARY CT ANGIOGRAPHY USING ULTRA-LOW DOSE CONTRAST MEDIA: RADIATION DOSE AND IMAGE QUALITY
    Komatsu, Sei
    Imai, Atsuko
    Kodama, Kazuhisa
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1357 - E1357