Radiation dose and image quality in intraoperative CT (iCT) angiography of the brain with stereotactic head frames

被引:1
|
作者
Forbrig, Robert [1 ]
Geyer, Lucas L. [2 ]
Stahl, Robert [3 ]
Thorsteinsdottir, Jun [4 ]
Schichor, Christian [4 ]
Kreth, Friedrich-Wilhelm [4 ]
Patzig, Maximilian [1 ]
Herzberg, Moriz [1 ]
Liebig, Thomas [1 ]
Dorn, Franziska [1 ]
Trumm, Christoph G. [5 ]
机构
[1] Ludwig Maximilians Univ Munchen, Univ Hosp, Inst Neuroradiol, Marchioninistr 15, D-81377 Munich, Germany
[2] Klinikum Ingolstadt, Ctr Radiol & Neuroradiol, Ingolstadt, Germany
[3] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Radiol, Munich, Germany
[4] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Neurosurg, Munich, Germany
[5] Stadt Klinikum Munchen Harlaching, Inst Diagnost & Intervent Radiol Neuroradiol & Nu, Munich, Germany
关键词
Brain; Radiation dosage; Neuronavigation; Computed tomography angiography; METAL ARTIFACT REDUCTION; ENERGY COMPUTED-TOMOGRAPHY; TUBE CURRENT MODULATION; 70; KVP; ITERATIVE RECONSTRUCTION; CONTRAST MATERIAL; BIOPSY; FEASIBILITY; MULTISLICE; VOLTAGE;
D O I
10.1007/s00330-018-5930-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesIntraoperative CT (iCT) angiography of the brain with stereotactic frames is an integral part of navigated neurosurgery. Validated data regarding radiation dose and image quality in these special examinations are not available. We therefore investigated two iCT protocols in this IRB-approved study.MethodsRetrospective analysis of patients, who received a cerebral stereotactic iCT angiography on a 128 slice CT scanner between February 2016 and December 2017. In group A, automated tube current modulation (ATCM; reference value 410mAs) and automated tube voltage selection (reference value 120kV) were enabled, and only examinations with a selected voltage of 120kV were included. In group B, fixed parameters were applied (300mAs, 120kV). Radiation dose was measured by assessing the volumetric CT dose index (CTDIvol), dose length product (DLP) and effective dose (ED). Signal-to-noise ratio (SNR) and image noise were assessed for objective image quality, visibility of arteries and grey-white differentiation for subjective image quality.ResultsTwo hundred patients (n=100 in each group) were included. In group A, median selected tube current was 643mAs (group B, 300mAs; p<0.001). Median values of CTDIvol, DLP and ED were 91.54mGy, 1561mGycm and 2.97mSv in group A, and 43.15mGy, 769mGycm and 1.46mSv in group B (p<0.001). Image quality did not significantly differ between groups (p>0.05).ConclusionsATCM yielded disproportionally high radiation dose due to substantial tube current increase at the frame level, while image quality did not improve. Thus, ATCM should preferentially be disabled.Key Points center dot Automated tube current modulation (ATCM) yields disproportionally high radiation dose in intraoperative CT angiography of the brain with stereotactic head frames.center dot ATCM does not improve overall image quality in these special examinations.center dot ATCM is not yet optimised for CT angiography of the brain with major extracorporeal foreign materials within the scan range.
引用
收藏
页码:2859 / 2867
页数:9
相关论文
共 50 条
  • [1] Radiation dose and image quality in intraoperative CT (iCT) angiography of the brain with stereotactic head frames
    Robert Forbrig
    Lucas L. Geyer
    Robert Stahl
    Jun Thorsteinsdottir
    Christian Schichor
    Friedrich-Wilhelm Kreth
    Maximilian Patzig
    Moriz Herzberg
    Thomas Liebig
    Franziska Dorn
    Christoph G. Trumm
    European Radiology, 2019, 29 : 2859 - 2867
  • [2] Radiation dose and image quality in head CT examinations
    Huda, W
    Chang, J
    Lieberman, KA
    Roskopf, ML
    RADIOLOGY, 2001, 221 : 160 - 160
  • [3] RADIATION DOSE AND IMAGE QUALITY IN PEDIATRIC HEAD CT
    Spampinato, Maria Vittoria
    Stalcup, Seth
    Matheus, Maria Gisele
    Byington, Kathleen
    Tyler, Michael
    Bickley, Stetson
    Tipnis, Sameer
    RADIATION PROTECTION DOSIMETRY, 2018, 182 (03) : 310 - 316
  • [4] Radiation dose in cardiac CT angiography: protocols and image quality
    Oliveira, L. C. G.
    Gottlieb, I.
    Rizzi, P.
    Lopes, R. T.
    Kodlulovich, S.
    RADIATION PROTECTION DOSIMETRY, 2013, 155 (01) : 73 - 80
  • [5] Comparison of the image quality and radiation dose of different scanning modes in head-neck CT angiography
    Zhang, Tianle
    Geng, Xue
    Li, Dongxue
    Xu, Yize
    Zhao, Yongxia
    DENTOMAXILLOFACIAL RADIOLOGY, 2021, 50 (05)
  • [6] Comparison of two different GSI scanning protocols in head and neck CT angiography: Image quality and radiation dose
    Zhang, Tianle
    Zhao, Sai
    Liu, Yiwen
    Liu, Zhichao
    Ma, Zepeng
    Zuo, Ziwei
    Zhao, Yongxia
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (04) : 689 - 696
  • [7] Iterative Reconstruction for Head CT: Effects on Radiation Dose and Image Quality
    Rivers-Bowerman, Michael D.
    Shankar, Jai Jai Shiva
    CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 2014, 41 (05) : 620 - 625
  • [8] Multiphase CT angiography versus single-phase CT angiography: Comparison of image quality and radiation dose
    Yang, C. -Y.
    Chen, Y. -F.
    Lee, C. -W.
    Huang, A.
    Shen, Y.
    Wei, C.
    Liu, H. -M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (07) : 1288 - 1295
  • [9] Radiation Dose and Image Quality Assessment of the Bolus Timing Method for CT Angiography
    Kim, Myeong Seong
    Lee, Jong-Woong
    Kim, Sun Geun
    Kweon, Dae Cheol
    IRANIAN JOURNAL OF RADIOLOGY, 2017, 14 (02)
  • [10] Comparison of Image Quality and Radiation Dose Between Single-Energy and Dual-Energy Images for the Brain With Stereotactic Frames on Dual-Energy Cerebral CT
    Zhao, Xiaojing
    Chao, Wang
    Shan, Yi
    Li, Jingkai
    Zhao, Cheng
    Zhang, Miao
    Lu, Jie
    FRONTIERS IN RADIOLOGY, 2022, 2