Radiation Dose and Image Quality Assessment of the Bolus Timing Method for CT Angiography

被引:2
|
作者
Kim, Myeong Seong [1 ]
Lee, Jong-Woong [2 ]
Kim, Sun Geun [3 ]
Kweon, Dae Cheol [4 ]
机构
[1] Korean Natl Canc Ctr, Dept Radiol, Goyang, South Korea
[2] Kyung Hee Univ Hosp Gang Dong, Dept Radiol, Seoul, South Korea
[3] Baekseok Culture Univ, Dept Radiol Technol, Cheonan, South Korea
[4] Shinhan Univ, Dept Radiol Sci, Uijongbu, South Korea
关键词
Angiography; Image Analysis; Multidetector Computed Tomography; Radiation Dosage; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; ROW HELICAL CT; CONTRAST MATERIAL; CORONARY-ANGIOGRAPHY; ARTERIAL PHASE; INDUCED CANCER; ENHANCEMENT; EXPOSURE; PRINCIPLES; REDUCTION;
D O I
10.5812/iranjradiol.31918
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Bolus timing monitoring scans used for computed tomography angiography (CTA) repetitively expose the same region of the body to radiation with a view to determining the appropriate threshold attenuation level of the contrast material (CM). Therefore, for an effective CT scan, it is necessary to minimize repetitive radiation exposures from bolus timing. Objectives: This study aims to effectively identify and reduce the radiation dose needed for repetitive monitoring scans utilized in CT involving the bolus timing method. Patients and Methods: To investigate the currently employed protocols and the number of monitoring scans in bolus timing CT studies, 983 patients (581 males and 402 females; mean age 62.7) were retrospectively analyzed from October 1, 2013 to March 31, 2014. To identify the appropriate kVp and mA change in the hounsfield unit (HU) and measure the contrast-to-noise ratio (CNR) and the signal-to-noise ratio (SNR) in the bolus timing method, a 2 mL syringe containing CM diluted with saline at a ratio of 1 to 300 was inserted into cavities of a CT dose index (CTDI) head phantom and scanned with a 64-section multi-detector row CT system. The dose variation was analyzed using results from the ionization chamber and CTDI. Results: This retrospective analysis of bolus-timing CT studies found that patients underwent an average of 4.5 to 5.4 monitoring scans. Furthermore, while the HU value of the mixed CM syringe in the central CTDI head phantom cavity was inversely proportional to mA, the decrease in the HU value became weaker at a value of 50 mA with 100 kVp and at 30mA with 120kVp. Here, the CNR(Pearson correlation r = 0.983, Kendall's t = 0.978, P < 0.000) became slightly higher with an increase in mA at 100 kVp compared to 120 kVp, whereas the SNR (Pearson correlation r = 0.997, Kendall's t = 1.0, P < 0.000) became similar to 100 kVp. Conclusion: It is recommended that minimum level of radiation (100 kVp, 50 mA; 120 kVp, 30 mA) at which the HU value at the trigger threshold is not significantly different from that of the actual helical scans should be used to minimize the radiation dose caused by repetitive monitoring scans in the bolus timing method.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Radiation dose in cardiac CT angiography: protocols and image quality
    Oliveira, L. C. G.
    Gottlieb, I.
    Rizzi, P.
    Lopes, R. T.
    Kodlulovich, S.
    RADIATION PROTECTION DOSIMETRY, 2013, 155 (01) : 73 - 80
  • [2] Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose
    Eun-Ah Park
    Whal Lee
    Kwang Woo Kim
    Kwang Gi Kim
    Allmendinger Thomas
    Jin Wook Chung
    Jae Hyung Park
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1775 - 1786
  • [3] Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose
    Park, Eun-Ah
    Lee, Whal
    Kim, Kwang Woo
    Kim, Kwang Gi
    Thomas, Allmendinger
    Chung, Jin Wook
    Park, Jae Hyung
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (07): : 1775 - 1786
  • [4] Multiphase CT angiography versus single-phase CT angiography: Comparison of image quality and radiation dose
    Yang, C. -Y.
    Chen, Y. -F.
    Lee, C. -W.
    Huang, A.
    Shen, Y.
    Wei, C.
    Liu, H. -M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (07) : 1288 - 1295
  • [5] Application of Aortic Computed Tomography Angiography with Low Radiation Dose: Assessment of Image Quality and Radiation Dose
    Liu, Jianhua
    Li, Long
    Zhang, Yan
    Yuan, Qinghai
    Sun, Yong
    2012 IEEE FIFTH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTATIONAL INTELLIGENCE (ICACI), 2012, : 148 - 151
  • [6] Adaptive Iterative Dose Reduction in coronary CT angiography using 320-row CT: Assessment of radiation dose reduction and image quality
    Tomizawa, Nobuo
    Nojo, Takeshi
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (05) : 318 - 324
  • [7] Low-dose CT angiography of the abdominal aorta and reduced contrast medium volume: Assessment of image quality and radiation dose
    Nijhof, W. H.
    Baltussen, E. J. M.
    Kant, I. M. J.
    Jager, G. J.
    Slump, C. H.
    Rutten, M. J. C. M.
    CLINICAL RADIOLOGY, 2016, 71 (01) : 64 - 73
  • [8] CT radiation dose and image quality
    Payne, JT
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2005, 43 (06) : 953 - +
  • [9] Effect of bismuth breast shielding on radiation dose and image quality in coronary CT angiography
    Andrew J. Einstein
    Carl D. Elliston
    Daniel W. Groves
    Bin Cheng
    Steven D. Wolff
    Gregory D. N. Pearson
    M. Robert Peters
    Lynne L. Johnson
    Sabahat Bokhari
    Gary W. Johnson
    Ketan Bhatia
    Theodore Pozniakoff
    David J. Brenner
    Journal of Nuclear Cardiology, 2012, 19 : 100 - 108
  • [10] Effect of bismuth breast shielding on radiation dose and image quality in coronary CT angiography
    Einstein, Andrew J.
    Elliston, Carl D.
    Groves, Daniel W.
    Cheng, Bin
    Wolff, Steven D.
    Pearson, Gregory D. N.
    Peters, M. Robert
    Johnson, Lynne L.
    Bokhari, Sabahat
    Johnson, Gary W.
    Bhatia, Ketan
    Pozniakoff, Theodore
    Brenner, David J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (01) : 100 - 108