Radiation Dose and Image Quality Assessment of the Bolus Timing Method for CT Angiography

被引:2
|
作者
Kim, Myeong Seong [1 ]
Lee, Jong-Woong [2 ]
Kim, Sun Geun [3 ]
Kweon, Dae Cheol [4 ]
机构
[1] Korean Natl Canc Ctr, Dept Radiol, Goyang, South Korea
[2] Kyung Hee Univ Hosp Gang Dong, Dept Radiol, Seoul, South Korea
[3] Baekseok Culture Univ, Dept Radiol Technol, Cheonan, South Korea
[4] Shinhan Univ, Dept Radiol Sci, Uijongbu, South Korea
关键词
Angiography; Image Analysis; Multidetector Computed Tomography; Radiation Dosage; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; ROW HELICAL CT; CONTRAST MATERIAL; CORONARY-ANGIOGRAPHY; ARTERIAL PHASE; INDUCED CANCER; ENHANCEMENT; EXPOSURE; PRINCIPLES; REDUCTION;
D O I
10.5812/iranjradiol.31918
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Bolus timing monitoring scans used for computed tomography angiography (CTA) repetitively expose the same region of the body to radiation with a view to determining the appropriate threshold attenuation level of the contrast material (CM). Therefore, for an effective CT scan, it is necessary to minimize repetitive radiation exposures from bolus timing. Objectives: This study aims to effectively identify and reduce the radiation dose needed for repetitive monitoring scans utilized in CT involving the bolus timing method. Patients and Methods: To investigate the currently employed protocols and the number of monitoring scans in bolus timing CT studies, 983 patients (581 males and 402 females; mean age 62.7) were retrospectively analyzed from October 1, 2013 to March 31, 2014. To identify the appropriate kVp and mA change in the hounsfield unit (HU) and measure the contrast-to-noise ratio (CNR) and the signal-to-noise ratio (SNR) in the bolus timing method, a 2 mL syringe containing CM diluted with saline at a ratio of 1 to 300 was inserted into cavities of a CT dose index (CTDI) head phantom and scanned with a 64-section multi-detector row CT system. The dose variation was analyzed using results from the ionization chamber and CTDI. Results: This retrospective analysis of bolus-timing CT studies found that patients underwent an average of 4.5 to 5.4 monitoring scans. Furthermore, while the HU value of the mixed CM syringe in the central CTDI head phantom cavity was inversely proportional to mA, the decrease in the HU value became weaker at a value of 50 mA with 100 kVp and at 30mA with 120kVp. Here, the CNR(Pearson correlation r = 0.983, Kendall's t = 0.978, P < 0.000) became slightly higher with an increase in mA at 100 kVp compared to 120 kVp, whereas the SNR (Pearson correlation r = 0.997, Kendall's t = 1.0, P < 0.000) became similar to 100 kVp. Conclusion: It is recommended that minimum level of radiation (100 kVp, 50 mA; 120 kVp, 30 mA) at which the HU value at the trigger threshold is not significantly different from that of the actual helical scans should be used to minimize the radiation dose caused by repetitive monitoring scans in the bolus timing method.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Split vs. Single Bolus CT Urography: Comparison of Scan Time, Image Quality and Radiation Dose
    Morrison, Nicole
    Bryden, Sherrie
    Costa, Andreu F.
    TOMOGRAPHY, 2021, 7 (02) : 210 - 218
  • [32] Bolus timing in high-pitch CT angiography of the aorta
    Beeres, Martin
    Loch, Matthias
    Schulz, Boris
    Kerl, Matthias
    Al-Butmeh, Firas
    Bodelle, Boris
    Herrmann, Eva
    Gruber-Rouh, Tatjana
    Lee, Clara
    Jacobi, Volkmar
    Vogl, Thomas J.
    Bauer, Ralf W.
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (06) : 1028 - 1033
  • [33] Comparison of the image quality and radiation dose of different scanning modes in head-neck CT angiography
    Zhang, Tianle
    Geng, Xue
    Li, Dongxue
    Xu, Yize
    Zhao, Yongxia
    DENTOMAXILLOFACIAL RADIOLOGY, 2021, 50 (05)
  • [34] High-pitch dual-source CT angiography of supra-aortic arteries: assessment of image quality and radiation dose
    A. Korn
    M. Fenchel
    B. Bender
    S. Danz
    C. Thomas
    D. Ketelsen
    C. D. Claussen
    G. Moonis
    B. Krauss
    M. Heuschmid
    U. Ernemann
    H. Brodoefel
    Neuroradiology, 2013, 55 : 423 - 430
  • [35] Pulmonary CT Angiography as First-Line Imaging for PE: Image Quality and Radiation Dose Considerations
    Mayo, John
    Thakur, Yogesh
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (03) : 522 - 528
  • [36] Cardiovascular CT angiography in neonates and children: Image quality and potential for radiation dose reduction with iterative image reconstruction techniques
    Tricarico, Francesco
    Hlavacek, Anthony M.
    Schoepf, U. Joseph
    Ebersberger, Ullrich
    Nance, John W., Jr.
    Vliegenthart, Rozemarijn
    Cho, Young Jun
    Spears, J. Reid
    Secchi, Francesco
    Savino, Giancarlo
    Marano, Riccardo
    Schoenberg, Stefan O.
    Bonomo, Lorenzo
    Apfaltrer, Paul
    EUROPEAN RADIOLOGY, 2013, 23 (05) : 1306 - 1315
  • [37] High-pitch dual-source CT angiography of supra-aortic arteries: assessment of image quality and radiation dose
    Korn, A.
    Fenchel, M.
    Bender, B.
    Danz, S.
    Thomas, C.
    Ketelsen, D.
    Claussen, C. D.
    Moonis, G.
    Krauss, B.
    Heuschmid, M.
    Ernemann, U.
    Brodoefel, H.
    NEURORADIOLOGY, 2013, 55 (04) : 423 - 430
  • [38] Radiation dose and diagnostic image quality associated with iterative reconstruction in coronary CT angiography: A systematic review
    Abdullah, Kamarul Amin
    McEntee, Mark F.
    Reed, Warren
    Kench, Peter L.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2016, 60 (04) : 459 - 468
  • [39] Cardiovascular CT angiography in neonates and children: Image quality and potential for radiation dose reduction with iterative image reconstruction techniques
    Francesco Tricarico
    Anthony M. Hlavacek
    U. Joseph Schoepf
    Ullrich Ebersberger
    John W. Nance
    Rozemarijn Vliegenthart
    Young Jun Cho
    J. Reid Spears
    Francesco Secchi
    Giancarlo Savino
    Riccardo Marano
    Stefan O. Schoenberg
    Lorenzo Bonomo
    Paul Apfaltrer
    European Radiology, 2013, 23 : 1306 - 1315
  • [40] Radiation dose and image quality in head CT examinations
    Huda, W
    Chang, J
    Lieberman, KA
    Roskopf, ML
    RADIOLOGY, 2001, 221 : 160 - 160