Image Quality in Computed Tomography Coronary Angiography and Radiation Dose Reduction

被引:1
|
作者
Golubickas, Domas [1 ]
Lukosevicius, Saulius [1 ]
Tamakauskas, Vytenis [2 ]
Dobrovolskiene, Laima [1 ]
Baseviciene, Ingrida [1 ]
Grib, Liviu [3 ]
Ragaisyte, Nijole [1 ]
Leonavicius, Rytis [1 ]
Medvedev, Viktor [4 ]
Veikutis, Vincentas [2 ]
机构
[1] Lithuanian Univ Hlth Sci, Kaunas, Lithuania
[2] Lithuanian Univ Hlth Sci, Inst Cardiol, Kaunas, Lithuania
[3] State Univ Med & Pharm Nicolae Testemitanu, Kishinev, Moldova
[4] Vilnius Univ, Inst Data Sci & Digital Technol, Vilnius, Lithuania
关键词
image quality; data analysis; computed tomography; coronary angiography; radiation dose; optimal scanning parameters; STATISTICAL ITERATIVE RECONSTRUCTION; DIAGNOSTIC-ACCURACY; CT ANGIOGRAPHY; 320-DETECTOR ROW; SCCT GUIDELINES; ARTERY-DISEASE; HEART-RATE; EXPOSURE; ACQUISITION; IDENTIFICATION;
D O I
10.15388/21-INFOR464
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Computed tomography coronary angiography (CTCA) is a non-invasive, powerful image processing technique for assessing coronary artery disease. The aim of the paper is to evaluate the diagnostic role of CTCA using optimal scanning parameters and to investigate the effect of low kilovoltage CTCA on the qualitative and quantitative image parameters and radiation dose in overweight and obese patients. Consolidation of knowledge in medicine and image processing was used to achieve the aim, and performance was evaluated in a clinical setting. Elevated body mass index is one of the factors causing increased radiation dose to patients. This study examined the feasibility of 80-kV and 100-kV CTCA in overweight and obese adult patients, comparing radiation doses and image quality versus standardized 100-kV protocols in the group of overweight patients and 120-kV CTCA in the group of obese patients. Qualitative and quantitative image parameters were determined in proximal and distal segments of the coronary arteries. Quantitative assessment was determined by the contrast-to-noise ratio and signal-to-noise ratio. The results of the study showed that in overweight and obese patients, the low dose protocol affords radiation dose reduction of 35% and 41%, respectively. Image quality was found to be diagnostically acceptable in all cases.
引用
收藏
页码:741 / 757
页数:17
相关论文
共 50 条
  • [1] Effect of dose reduction on image quality and diagnostic performance in coronary computed tomography angiography
    Noortje van der Bijl
    Raoul M. S. Joemai
    Bart J. A. Mertens
    Albert de Roos
    Wouter J. H. Veldkamp
    Jeroen J. Bax
    Joanne D. Schuijf
    Jacob Geleijns
    Lucia J. M. Kroft
    The International Journal of Cardiovascular Imaging, 2013, 29 : 453 - 461
  • [2] Effect of dose reduction on image quality and diagnostic performance in coronary computed tomography angiography
    van der Bijl, Noortje
    Joemai, Raoul M. S.
    Mertens, Bart J. A.
    de Roos, Albert
    Veldkamp, Wouter J. H.
    Bax, Jeroen J.
    Schuijf, Joanne D.
    Geleijns, Jacob
    Kroft, Lucia J. M.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (02): : 453 - 461
  • [3] Radiation dose reduction with deep-learning image reconstruction for coronary computed tomography angiography
    Dominik C. Benz
    Sara Ersözlü
    François L. A. Mojon
    Michael Messerli
    Anna K. Mitulla
    Domenico Ciancone
    David Kenkel
    Jan A. Schaab
    Catherine Gebhard
    Aju P. Pazhenkottil
    Philipp A. Kaufmann
    Ronny R. Buechel
    European Radiology, 2022, 32 : 2620 - 2628
  • [4] Radiation dose reduction with deep-learning image reconstruction for coronary computed tomography angiography
    Benz, Dominik C.
    Ersoezlue, Sara
    Mojon, Francois L. A.
    Messerli, Michael
    Mitulla, Anna K.
    Ciancone, Domenico
    Kenkel, David
    Schaab, Jan A.
    Gebhard, Catherine
    Pazhenkottil, Aju P.
    Kaufmann, Philipp A.
    Buechel, Ronny R.
    EUROPEAN RADIOLOGY, 2022, 32 (04) : 2620 - 2628
  • [5] Radiation dose reduction in paediatric coronary computed tomography: assessment of effective dose and image quality
    Geryes, Bouchra Habib
    Calmon, Raphael
    Khraiche, Diala
    Boddaert, Nathalie
    Bonnet, Damien
    Raimondi, Francesca
    EUROPEAN RADIOLOGY, 2016, 26 (07) : 2030 - 2038
  • [6] Radiation dose reduction in paediatric coronary computed tomography: assessment of effective dose and image quality
    Bouchra Habib Geryes
    Raphael Calmon
    Diala Khraiche
    Nathalie Boddaert
    Damien Bonnet
    Francesca Raimondi
    European Radiology, 2016, 26 : 2030 - 2038
  • [7] Evaluation of image quality and radiation dose in low tube voltage coronary computed tomography angiography
    Mousavi-Gazafroudi, Seyedeh Shokoofeh
    Sajjadieh-Khajouei, Amirreza
    Moradi, Maryam
    Mousavi-Gazafroudi, Seyedeh Shabnam
    Yadegarfar, Ghasem
    Tavakoli, Mohammad Bagher
    ARYA ATHEROSCLEROSIS, 2019, 15 (05) : 205 - 210
  • [8] Image Quality and Dose Reduction by Dual Source Computed Tomography Coronary Angiography: Protocol Comparison
    Forte, Ernesto
    Monti, Serena
    Parente, Chiara Anna
    Beyer, Lukas
    De Rosa, Roberto
    Infante, Teresa
    Cavaliere, Carlo
    Cademartiri, Filippo
    Salvatore, Marco
    Stroszczynski, Christian
    Tedeschi, Carlo
    DOSE-RESPONSE, 2018, 16 (04):
  • [9] FEASIBILITY OF RADIATION DOSE REDUCTION FOR CORONARY COMPUTED TOMOGRAPHY ANGIOGRAPHY WITH DEEP-LEARNING IMAGE RECONSTRUCTION
    Benz, Dominik C.
    Mojon, Francois
    Kaufmann, Philipp A.
    Buechel, Ronny R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 1252 - 1252
  • [10] Coronary computed tomography angiography with prospective electrocardiography triggering: a systematic review of image quality and radiation dose
    Sabarudin, Akmal
    Sun, Zhonghua
    Ng, Kwan-Hoong
    SINGAPORE MEDICAL JOURNAL, 2013, 54 (01) : 15 - 23