Image Quality in Computed Tomography Coronary Angiography and Radiation Dose Reduction

被引:1
|
作者
Golubickas, Domas [1 ]
Lukosevicius, Saulius [1 ]
Tamakauskas, Vytenis [2 ]
Dobrovolskiene, Laima [1 ]
Baseviciene, Ingrida [1 ]
Grib, Liviu [3 ]
Ragaisyte, Nijole [1 ]
Leonavicius, Rytis [1 ]
Medvedev, Viktor [4 ]
Veikutis, Vincentas [2 ]
机构
[1] Lithuanian Univ Hlth Sci, Kaunas, Lithuania
[2] Lithuanian Univ Hlth Sci, Inst Cardiol, Kaunas, Lithuania
[3] State Univ Med & Pharm Nicolae Testemitanu, Kishinev, Moldova
[4] Vilnius Univ, Inst Data Sci & Digital Technol, Vilnius, Lithuania
关键词
image quality; data analysis; computed tomography; coronary angiography; radiation dose; optimal scanning parameters; STATISTICAL ITERATIVE RECONSTRUCTION; DIAGNOSTIC-ACCURACY; CT ANGIOGRAPHY; 320-DETECTOR ROW; SCCT GUIDELINES; ARTERY-DISEASE; HEART-RATE; EXPOSURE; ACQUISITION; IDENTIFICATION;
D O I
10.15388/21-INFOR464
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Computed tomography coronary angiography (CTCA) is a non-invasive, powerful image processing technique for assessing coronary artery disease. The aim of the paper is to evaluate the diagnostic role of CTCA using optimal scanning parameters and to investigate the effect of low kilovoltage CTCA on the qualitative and quantitative image parameters and radiation dose in overweight and obese patients. Consolidation of knowledge in medicine and image processing was used to achieve the aim, and performance was evaluated in a clinical setting. Elevated body mass index is one of the factors causing increased radiation dose to patients. This study examined the feasibility of 80-kV and 100-kV CTCA in overweight and obese adult patients, comparing radiation doses and image quality versus standardized 100-kV protocols in the group of overweight patients and 120-kV CTCA in the group of obese patients. Qualitative and quantitative image parameters were determined in proximal and distal segments of the coronary arteries. Quantitative assessment was determined by the contrast-to-noise ratio and signal-to-noise ratio. The results of the study showed that in overweight and obese patients, the low dose protocol affords radiation dose reduction of 35% and 41%, respectively. Image quality was found to be diagnostically acceptable in all cases.
引用
收藏
页码:741 / 757
页数:17
相关论文
共 50 条
  • [31] Routine low-radiation-dose coronary computed tomography angiography
    Al-Mallah, Mouaz H.
    Aljizeeri, Ahmed
    Alharthi, Mohsen
    Alsaileek, Ahmed
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2014, 16 (0B) : B12 - B16
  • [32] Reducing Radiation Dose in Coronary Computed Tomography Angiography We Are Not There Yet
    LaBounty, Troy M.
    JACC-CARDIOVASCULAR IMAGING, 2020, 13 (02) : 435 - 436
  • [33] Radiation Dose and Image Quality of a High-Pitch Prospective Spiral First Approach in Coronary Computed Tomography Angiography (CCTA)
    Finck, Tom
    Klambauer, Konstantin
    Hendrich, Eva
    Will, Albrecht
    Martinoff, Stefan
    Hadamitzky, Martin
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2021, 8 (10)
  • [34] Low radiation dose computed tomography coronary angiography: evaluation of the variations in coronary arteries
    Nurullah Dogan
    Aydin Dursun
    Hakan Ozkan
    Serdar Karataş
    Nuran Celiloglu
    Fahriye Vatansever Agca
    Surgical and Radiologic Anatomy, 2016, 38 : 1123 - 1134
  • [35] Low radiation dose computed tomography coronary angiography: evaluation of the variations in coronary arteries
    Dogan, Nurullah
    Dursun, Aydin
    Ozkan, Hakan
    Karatas, Serdar
    Celiloglu, Nuran
    Agca, Fahriye Vatansever
    SURGICAL AND RADIOLOGIC ANATOMY, 2016, 38 (10) : 1123 - 1134
  • [36] Effects of Dose Reduction on Diagnostic Image Quality of Coronary Computed Tomography Angiography in Children Using a Third-Generation Dual-Source Computed Tomography Scanner
    Rashed, Moustafa
    Banka, Puja
    Barthur, Ashita
    MacDougal, Robert D.
    Rathod, Rahul H.
    Powell, Andrew J.
    Prakash, Ashwin
    AMERICAN JOURNAL OF CARDIOLOGY, 2018, 122 (07): : 1260 - 1264
  • [37] REDUCTION OF RADIATION DOSE OF 320-ROW CORONARY COMPUTED TOMOGRAPHY ANGIOGRAPHY THROUGH PRIOR CORONARY CALCIUM SCANNING
    Dewey, Marc
    Zimmermann, Elke
    Wollenberg, Ulrike
    Rief, Matthias
    Greupner, Johannes
    Hamm, Bernd
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [38] Influence of cardiac function on image quality in coronary computed tomography angiography
    Nguyen, Tien C.
    Ohyama, Yoshiaki
    Taketomi-Takahashi, Ayako
    Nguyen, Huong T.
    Sugimoto, Akio
    Sato, Makito
    Sumiyoshi, Hisako
    Nakamura, Tetsuya
    Kurabayashi, Masahiko
    Tsushima, Yoshito
    CLINICAL IMAGING, 2019, 53 : 58 - 64
  • [39] Image Quality of 256-Slice Computed Tomography for Coronary Angiography
    Chao, Shu-Ping
    Leu, Jyh-Gang
    Law, Wai-Yip
    Kuo, Chu-Jen
    Shyu, Kou-Gi
    ACTA CARDIOLOGICA SINICA, 2013, 29 (05) : 444 - 450
  • [40] Computed Tomography Angiography with a 192-slice Dual-source Computed Tomography System: Improvements in Image Quality and Radiation Dose
    Linsen, Philip V. M.
    Coenen, Adriaan
    Lubbers, Marisa M.
    Dijkshoorn, Marcel L.
    Ouhlous, Mohamed
    Nieman, Koen
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2016, 6