Comparison of HbA1c detection in whole blood and dried blood spots using an automated ion-exchange HPLC system

被引:18
|
作者
Maleska, Aleksandra [1 ,2 ,3 ]
Hirtz, Christophe [1 ]
Casteleyn, Elise [1 ]
Villard, Orianne [4 ]
Ducos, Jacques [2 ,3 ]
Avignon, Antoine [4 ]
Sultan, Ariane [4 ]
Lehmann, Sylvain [1 ]
机构
[1] Univ Montpellier, CHU Montpellier, INSERM U1183, Lab Biochim Proteom Clin, F-34000 Montpellier, France
[2] CHU Montpellier, Hop Lapeyronie, Lab Virol, F-34000 Montpellier, France
[3] INSERM, U1058, F-34000 Montpellier, France
[4] Univ Montpellier, Univ Hosp, CNRS UMR 9214, PhyMedExp,INSERM U1046,Endocrinol Diabetol Nutr D, Montpellier, France
关键词
clinical biology; DBS; dried blood spot; glycated hemoglobin; HbA1c; HPLC; ion exchange; ISO15189; method validation; DIABETES CONTROL; COMPLICATIONS TRIAL/EPIDEMIOLOGY; HEMOGLOBIN A1C; FILTER-PAPER; INTERVENTIONS; OUTCOMES; GLUCOSE; PATIENT; HBA(1C); SAMPLES;
D O I
10.4155/bio-2016-0278
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Aim: Hemoglobin A1c (HbA1c) is a widely recognized analyte for diagnosing and monitoring diabetes. Dried blood spot (DBS) constitutes a useful alternative to blood collection by venipuncture. Analytical and clinical validation of DBS use is, however, necessary before implementation. Results/methodology: HbA1c levels from whole blood or DBS from a cohort patients with diabetes were compared. DBS specimens were stable at ambient temperature. HbA1c detection on DBS was accurate, robust, and the correlation and agreement with whole blood values was excellent. Conclusion: This study provides for the first time a complete method comparison and validation under the ISO15189 guideline using an automated HPLC system. This approach constitutes, therefore, a useful tool for diagnosing diabetes.
引用
收藏
页码:427 / 434
页数:8
相关论文
共 50 条
  • [31] A disposable electrochemical sensor designed to estimate glycated hemoglobin (HbA1c) level in whole blood
    Thiruppathi, Murugan
    Lee, Ju-Fang
    Chen, Cheng Che
    Ho, Ja-an Annie
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 329
  • [32] Validation of self-collected capillary dried blood spot collection for clinical HbA1c testing
    Naranjo, A.
    Carter, C.
    CLINICAL CHEMISTRY, 2024, 70 : I21 - I21
  • [33] Measurement of HbA1c from stored whole blood samples in the Atherosclerosis Risk in Communities study
    Selvin, Elizabeth
    Coresh, Josef
    Zhu, Hong
    Folsom, Aaron
    Steffes, Michael W.
    JOURNAL OF DIABETES, 2010, 2 (02) : 118 - 124
  • [34] SIMULTANEOUS DETECTION OF HEPATITIS C VIRUS ANTIGEN AND ANTIBODIES USING DRIED BLOOD SPOTS SAMPLES
    Villar, L. M.
    Brandao, C. P. U.
    Marques, B. L. C.
    da Silva, E. F.
    Marques, V. A.
    Villela-Nogueira, C. A.
    do O, K. M. R.
    de Paula, M. T.
    Lewis-Ximenez, L. L.
    Sa Ferreira, J. A.
    Lampe, E.
    JOURNAL OF HEPATOLOGY, 2013, 58 : S208 - S208
  • [36] The comparison of ion exchange-high performance liquid chromatography (IE-HPLC) and capillary electrophoresis (CE) for HbA1C measurement
    Sutrisnani, Catur Suci
    Darmawan, Edwin
    Widijanti, Anik
    Soehita, Sidarti
    BALI MEDICAL JOURNAL, 2019, 8 (02) : 316 - 322
  • [37] Interference of hemoglobinA1c (HbA1c) detection using ion-exchange high performance liquid chromatography (HPLC) method by clinically silent hemoglobin variant in University Malaya Medical Centre (UMMC)-A case report
    Thevarajah, M.
    Nadzirnah, M. N.
    Chew, Y. Y.
    CLINICAL BIOCHEMISTRY, 2009, 42 (4-5) : 430 - 434
  • [38] Development of aptamer based colorimetric assay for whole blood glycated hemoglobin (HbA1c) estimation using gold nanoparticles
    Devi R.
    Chauhan A.
    Yadav S.
    Kumar P.
    Pundir C.S.
    Biosensors and Bioelectronics: X, 2023, 13
  • [39] Haemoglobin A1c determination from dried blood spots prepared with HemaSpot™ blood collection devices: comparison with fresh capillary blood
    Hall, Jenny M.
    Fowler, Claire F.
    Pollock, M. Anne
    MacRury, Sandra M.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (02) : E79 - E82
  • [40] Evaluation of Bio-Rad D100 for HbA1c testing of dried blood spot samples
    Wei, Ruhan
    Kroner, Grace
    Reineks, Edmunds
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2022, 158 (SUPP 1) : S11 - S11