Comparison of HbA1c detection in whole blood and dried blood spots using an automated ion-exchange HPLC system

被引:18
|
作者
Maleska, Aleksandra [1 ,2 ,3 ]
Hirtz, Christophe [1 ]
Casteleyn, Elise [1 ]
Villard, Orianne [4 ]
Ducos, Jacques [2 ,3 ]
Avignon, Antoine [4 ]
Sultan, Ariane [4 ]
Lehmann, Sylvain [1 ]
机构
[1] Univ Montpellier, CHU Montpellier, INSERM U1183, Lab Biochim Proteom Clin, F-34000 Montpellier, France
[2] CHU Montpellier, Hop Lapeyronie, Lab Virol, F-34000 Montpellier, France
[3] INSERM, U1058, F-34000 Montpellier, France
[4] Univ Montpellier, Univ Hosp, CNRS UMR 9214, PhyMedExp,INSERM U1046,Endocrinol Diabetol Nutr D, Montpellier, France
关键词
clinical biology; DBS; dried blood spot; glycated hemoglobin; HbA1c; HPLC; ion exchange; ISO15189; method validation; DIABETES CONTROL; COMPLICATIONS TRIAL/EPIDEMIOLOGY; HEMOGLOBIN A1C; FILTER-PAPER; INTERVENTIONS; OUTCOMES; GLUCOSE; PATIENT; HBA(1C); SAMPLES;
D O I
10.4155/bio-2016-0278
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Aim: Hemoglobin A1c (HbA1c) is a widely recognized analyte for diagnosing and monitoring diabetes. Dried blood spot (DBS) constitutes a useful alternative to blood collection by venipuncture. Analytical and clinical validation of DBS use is, however, necessary before implementation. Results/methodology: HbA1c levels from whole blood or DBS from a cohort patients with diabetes were compared. DBS specimens were stable at ambient temperature. HbA1c detection on DBS was accurate, robust, and the correlation and agreement with whole blood values was excellent. Conclusion: This study provides for the first time a complete method comparison and validation under the ISO15189 guideline using an automated HPLC system. This approach constitutes, therefore, a useful tool for diagnosing diabetes.
引用
收藏
页码:427 / 434
页数:8
相关论文
共 50 条
  • [41] Glycated hemoglobin (HbA1c) measurement in frozen whole blood depends on baseline values of fresh samples
    Liotta, Luigi
    Di Franco, Alessandra
    Pazzagli, Mario
    Luconi, Michaela
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (01) : 429 - 434
  • [42] Capillary blood on filter paper for determination of HbA(1c) by ion exchange chromatography
    Jeppsson, JO
    Jerntorp, P
    Almer, LO
    Persson, R
    Ekberg, G
    Sundkvist, G
    DIABETES CARE, 1996, 19 (02) : 142 - 145
  • [43] A glycosylated hemoglobin (HbA1c) biosensing in human whole blood based on the boronate-diol interaction
    Yoon, Ho Won
    Yoon, Hyun C.
    JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2009, 108 : S156 - S156
  • [44] HAEMOGLOBIN VARIANTS AND THEIR INTERFERENCE IN HBA1C DETECTION USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)
    Sosa Moncayo, D.
    Benayas Bellido, P.
    Molina Arrebola, M.
    Gonzalez Raya, A.
    MartinezFernandez, J.
    Avivar Oyonarte, C.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S404 - S404
  • [45] Direct assay for quantitative measurement of percent HbA1c in anticoagulated whole blood on the Abbott AxSYM® analyzer
    Lawlor, M
    Geekie, C
    Detzner, K
    Milne, K
    CLINICA CHIMICA ACTA, 2005, 355 : S345 - S345
  • [46] Glycated hemoglobin (HbA1c) measurement in frozen whole blood depends on baseline values of fresh samples
    Luigi Liotta
    Alessandra Di Franco
    Mario Pazzagli
    Michaela Luconi
    Analytical and Bioanalytical Chemistry, 2013, 405 : 429 - 434
  • [47] Noninvasive estimation of blood glucose and HbA1c using Quantum Machine Learning technique
    Sridevi, Parama
    Rabbani, Masud
    Aziz, Md Hasanul
    Upama, Paramita Basak
    Mamun, Sayed Mashroor
    Khan, Rumi Ahmed
    Ahamed, Sheikh Iqbal
    MACHINE LEARNING WITH APPLICATIONS, 2025, 19
  • [48] INCLUDING TIME OF EFFECT OF AN INTERVENTION ON BLOOD SUGAR CONTROL USING THE SLOPE OF HBA1C%
    Kearns, P.
    Aguinaldo, T.
    Liu, H.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2009, 57 (03) : 528 - 528
  • [49] Electrochemical detection of HbA1c, a maker for diabetes, using a flow immunoassay system
    Tanaka, Tsuyoshi
    Tsukube, Shoko
    Izawa, Kojiro
    Okochi, Mina
    Lim, Tae-Kyu
    Watanabe, Shugo
    Harada, Manabu
    Matsunaga, Tadashi
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (9-10): : 2051 - 2056
  • [50] Stability of haemoglobin A1c (HbA1c) measurements from frozen whole blood samples stored for over a decade
    Selvin, E
    Coresh, J
    Jordahl, J
    Boland, L
    Steffes, MW
    DIABETIC MEDICINE, 2005, 22 (12) : 1726 - 1730