The comparison of ion exchange-high performance liquid chromatography (IE-HPLC) and capillary electrophoresis (CE) for HbA1C measurement

被引:0
|
作者
Sutrisnani, Catur Suci [1 ]
Darmawan, Edwin [2 ]
Widijanti, Anik [2 ]
Soehita, Sidarti [3 ]
机构
[1] Airlangga Univ, Clin Pathol Dept, Fac Med, Surabaya, Indonesia
[2] Brawijaya Univ, Dept Clin Pathol, Fac Med, Dr Saiful Anwar Hosp, Malang, Indonesia
[3] Airlangga Univ, Dept Clin Pathol, Fac Med, Dr Soetomo Hosp, Surabaya, Indonesia
关键词
HbA1c; measurement; HPLC; CE; HEMOGLOBIN A(1C) MEASUREMENT; PROGRAM; GOALS;
D O I
10.15562/bmj.v8i2.1379
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: HbA1c is glycosylated hemoglobin that routinely performed in a patient with Diabetes Mellitus. There are several methods for HbA1c measurement. One of them is based on the molecular charge such as High-Performance Liquid Chromatography (HPLC) and Capillary Electrophoresis (CE). Each method has its advantages and disadvantages. Thus, the selection of HbA1c measurement method is an important thing. This study was aimed to compare HbA1c measurement with HPLC and CE method. Methods: HbA1c measurement was done by HPLC and CE methods in 110 patient samples which have data of average blood glucose level during three months. We investigate the correlation of HbA1c results with average blood glucose level during three months, precision, methods comparison and interference including Hb variant. This study was conducted in the Central Laboratory of dr. Saiful Anwar Hospital during March-August 2018. Correlation analysis was done by Pearson analysis while precision test and methods comparison were done by Bland Altman Plot and Passing-Bablok Regression analysis. Results: There were correlation between estimated Average Glucose from HbA1c (eAGHbA1c) calculation with an average blood glucose level during 3 months in both methods. From precision test we found intraassay coefficient of variation in normal level (HbA1c +/- 5%) by HPLC vs CE was 1,7% vs 0.63% and in high level (HbA1c +/- 11%) was 0,59% vs 0,61% and inter-assay coefficient of variation by HPLC vs CE was 2,47% vs 2,17%. Method comparison results showed a strong correlation on both methods. The results of HbA1c in the group without Hb variant by CE method was slightly lower than HPLC. In Hb variant group, the CE method was slightly higher than HPLC, but it was not significant for HbA1c interpretation. Conclusion: HbA1c measurement by HPLC and CE method are comparable, and there is no significant difference in the results obtained.
引用
收藏
页码:316 / 322
页数:7
相关论文
共 50 条
  • [1] INCIDENCE AND INTERFERENCE OF HEMOGLOBIN VARIANTS ON HBA1C MEASUREMENT USING HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY AND CAPILLARY ELECTROPHORESIS
    Van den Bossche, Jan
    Asselman, Valerie
    Luyckx, Kim
    De Block, Christophe
    Van Gaal, Luc
    Van Hoof, Viviane
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2016, 38 : 111 - 111
  • [2] New HPLC instrument performance evaluation in HbA1c determination and comparison with capillary electrophoresis
    Khashoggi, Haneen
    Pignalosa, Stefano
    Russo, Carmelo
    Pieri, Massimo
    Bernardini, Sergio
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2018, 78 (05): : 393 - 397
  • [3] Niacin determination in legumes by capillary electrophoresis (CE). Comparison with high performance liquid chromatography (HPLC)
    Diaz-Pollan, C
    Vidal-Valverde, C
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1998, 21 (02): : 81 - 86
  • [4] Niacin determination in legumes by capillary electrophoresis (CE). Comparison with high performance liquid chromatography (HPLC)
    Diaz-Poilan, Concepcion
    Vidal-Valverde, Concepcion
    1998, (21):
  • [5] HbA1c analysis by capillary electrophoresis - comparison with chromatography and an immunological method
    Klingenberg, Olav
    Furuset, Torill
    Hestbraten, Camilla R.
    Hallberg, Marit H.
    Steiro, Astrid
    Orset, Iren R.
    Berg, Jens P.
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2017, 77 (06): : 458 - 464
  • [6] Influence of RBC Indices on HbA1c Measurement by Capillary Electrophoresis and HPLC Methods
    Juang, Yi-Jie
    Wu, Hsin-Mian
    Cheng, Ya-Wen
    Eng, Hock-Liew
    Lin, Tsun-Mei
    CLINICAL LABORATORY, 2022, 68 (08) : 1657 - 1665
  • [7] Evaluation of an Ion-Exchange HPLC Device for HbA1c Measurement
    Altawallbeh, Ghaith
    Makky, Vicky F.
    Saenger, Amy K.
    Peters, Jennifer M.
    Killeen, Anthony A.
    JOURNAL OF APPLIED LABORATORY MEDICINE, 2020, 5 (04): : 695 - 703
  • [8] Capillary blood HbA1c measurement by HPLC.
    Arribas, I
    Ruiz-Alvarez, MJ
    Franco, P
    Gómez-Sereno, B
    Gaspar, MJ
    Varela, LA
    Ramírez, J
    Coca, MC
    CLINICAL CHEMISTRY, 2003, 49 (06) : A129 - A129
  • [9] Comparison of two different device results measuring HbA1c by high performance liquid chromatography (HPLC) method
    Gurpinar, Ahmet Burak
    Cihan, Murat
    Noyan, Tevfik
    Demirhan, Erhan Seyfi
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2024, 15 (05): : 313 - 317
  • [10] HbA1c determination with high-performance liquid chromatography
    Schnedl, WJ
    Stepan, VM
    Roller, RE
    Lipp, RW
    DIABETES CARE, 2000, 23 (06) : 874 - 875