The comparison of ion exchange-high performance liquid chromatography (IE-HPLC) and capillary electrophoresis (CE) for HbA1C measurement

被引:0
|
作者
Sutrisnani, Catur Suci [1 ]
Darmawan, Edwin [2 ]
Widijanti, Anik [2 ]
Soehita, Sidarti [3 ]
机构
[1] Airlangga Univ, Clin Pathol Dept, Fac Med, Surabaya, Indonesia
[2] Brawijaya Univ, Dept Clin Pathol, Fac Med, Dr Saiful Anwar Hosp, Malang, Indonesia
[3] Airlangga Univ, Dept Clin Pathol, Fac Med, Dr Soetomo Hosp, Surabaya, Indonesia
关键词
HbA1c; measurement; HPLC; CE; HEMOGLOBIN A(1C) MEASUREMENT; PROGRAM; GOALS;
D O I
10.15562/bmj.v8i2.1379
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: HbA1c is glycosylated hemoglobin that routinely performed in a patient with Diabetes Mellitus. There are several methods for HbA1c measurement. One of them is based on the molecular charge such as High-Performance Liquid Chromatography (HPLC) and Capillary Electrophoresis (CE). Each method has its advantages and disadvantages. Thus, the selection of HbA1c measurement method is an important thing. This study was aimed to compare HbA1c measurement with HPLC and CE method. Methods: HbA1c measurement was done by HPLC and CE methods in 110 patient samples which have data of average blood glucose level during three months. We investigate the correlation of HbA1c results with average blood glucose level during three months, precision, methods comparison and interference including Hb variant. This study was conducted in the Central Laboratory of dr. Saiful Anwar Hospital during March-August 2018. Correlation analysis was done by Pearson analysis while precision test and methods comparison were done by Bland Altman Plot and Passing-Bablok Regression analysis. Results: There were correlation between estimated Average Glucose from HbA1c (eAGHbA1c) calculation with an average blood glucose level during 3 months in both methods. From precision test we found intraassay coefficient of variation in normal level (HbA1c +/- 5%) by HPLC vs CE was 1,7% vs 0.63% and in high level (HbA1c +/- 11%) was 0,59% vs 0,61% and inter-assay coefficient of variation by HPLC vs CE was 2,47% vs 2,17%. Method comparison results showed a strong correlation on both methods. The results of HbA1c in the group without Hb variant by CE method was slightly lower than HPLC. In Hb variant group, the CE method was slightly higher than HPLC, but it was not significant for HbA1c interpretation. Conclusion: HbA1c measurement by HPLC and CE method are comparable, and there is no significant difference in the results obtained.
引用
收藏
页码:316 / 322
页数:7
相关论文
共 50 条
  • [21] A comparison between turbidimetric inhibition immunoassay and capillary electrophoresis in glycated hemoglobin (HbA1c) measurement
    Aksungar, Fehime Benli
    Serteser, Mustafa
    Coskun, Abdurrahman
    Unsal, Ibrahim
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (08) : E191 - E193
  • [22] Making the switch from high performance liquid chromatography (HPLC) to capillary electrophoresis (CE)-The Edinburgh experience
    Ryan, P.
    CLINICA CHIMICA ACTA, 2019, 493 : S512 - S512
  • [23] Performance evaluation of three automated high performance liquid chromatography HBA1C analysers
    Lim, M. H.
    Koh, B. M. Q.
    Yeo, C. P.
    CLINICA CHIMICA ACTA, 2022, 530 : S293 - S293
  • [24] Common Hemoglobin Variants in Southern Taiwan and Their Effect on the Determination of HbA1c by Ion-exchange High-performance Liquid Chromatography
    Chu, Chih-Hsun
    Lam, Hing-Chung
    Lee, Jenn-Kuen
    Wang, Mei-Chun
    Lu, Chih-Chen
    Sun, Chun-Chin
    Chuang, Ming-Ju
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2009, 72 (07) : 362 - 367
  • [25] The determination of nitrate in spinach and Japanese radishes by RQflex, portable ion electrode (pIE), high performance liquid chromatography (HPLC) and high performance capillary electrophoresis (CE)
    Ito, H
    Horie, H
    Nagai, Y
    Ippoushi, K
    Azuma, K
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON QUALITY IN CHAINS, VOLS 1 AND 2: AN INTEGRATED VIW ON FRUIT AND VEGETABLE QUALITY, 2003, (604): : 545 - 548
  • [26] Comparison of HbA2 Using High Performance Liquid Chromatography Versus Haemoglobin Capillary Zone Electrophoresis
    Gurpreet Kaur
    Seema Tyagi
    Tulika Seth
    Manoranjan Mahapatra
    Ganesh Kumar Viswananthan
    Jasmita Dass
    Rama Hariharan
    Arijit Sen
    Indian Journal of Hematology and Blood Transfusion, 2023, 39 : 572 - 578
  • [27] Comparison of HbA2 Using High Performance Liquid Chromatography Versus Haemoglobin Capillary Zone Electrophoresis
    Kaur, Gurpreet
    Tyagi, Seema
    Seth, Tulika
    Mahapatra, Manoranjan
    Viswananthan, Ganesh Kumar
    Dass, Jasmita
    Hariharan, Rama
    Sen, Arijit
    INDIAN JOURNAL OF HEMATOLOGY AND BLOOD TRANSFUSION, 2023, 39 (04) : 572 - 578
  • [28] Comparing a Direct Whole Blood Enzymatic Assay With High-Performance Liquid Chromatography for HbA1c Measurement
    Zechmeister, Bozena
    Fischer, Andreas
    Eidizadeh, Abass
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024, 18 (01): : 244 - 246
  • [29] Comparison of HbA1c measurement methods between automatic boronate affinity point of care testing and high-performance liquid chromatography
    Tjahjadi, Ricky
    Giantini, Astuti
    BALI MEDICAL JOURNAL, 2019, 8 (01) : 270 - 274
  • [30] COMPARISON OF IN-HOUSE DEVELOPED ELISA WITH HPLC FOR MEASUREMENT OF HBA1C
    Mohsin, Saima Naz
    Ghafoor, Farkhanda
    Aasim, Muhammad
    JOURNAL OF IMMUNOASSAY & IMMUNOCHEMISTRY, 2013, 34 (03): : 305 - 312