Interference of hemoglobinA1c (HbA1c) detection using ion-exchange high performance liquid chromatography (HPLC) method by clinically silent hemoglobin variant in University Malaya Medical Centre (UMMC)-A case report

被引:26
|
作者
Thevarajah, M. [1 ]
Nadzirnah, M. N. [1 ]
Chew, Y. Y. [2 ]
机构
[1] Univ Malaya, Med Ctr, Dept Pathol, Fac Med, Kuala Lumpur 50903, Malaysia
[2] Univ Malaya, Med Ctr, Clin Diagnost Lab, Kuala Lumpur 50903, Malaysia
关键词
HbA1c; Hemoglobin variants; Ion-exchange HPLC; HBA(1C); PROGRAM;
D O I
10.1016/j.clinbiochem.2008.10.015
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Glycated hemoglobin, measured as HbA1c is used as an index of mean glycemia in diabetic patients over the preceding 23 months. Various assay methods are used to measure HbA1c and many factors may interfere with its measurement according to assay method used, causing falsely high or low results. Objective: To report a case of diabetic patient with clinically silent hemoglobin variant, causing undetectable HbA1c concentration using ion-exchange high performance liquid chromatography (HPLC) method. Case summary: Our patient is a 65-year-old female with type 2 diabetes mellitus oil diet control. hypertension and hypercholesterolemia. Her fasting blood glucose concentrations ranged from 6.2 to 7.8 mmol/L. Her HbA1c concentrations measured with immunoturbidimetry method (Cobas Integra, Roche Diagnostics) ranged from 6.11 to 7.23%, but were undetectable when measured with ion-exchange HPLC [Arkray HA8160, Diabetes Mode (also known as Menarini HA8160)]. Hemoglobin analysis identified the presence of a hemoglobin variant Hemoglobin D Punjab. Conclusions: Clinical laboratories should be aware of limitations of the HbA1c assay method used, Such as potential interference with hemoglobin variant as depicted by our case. Alternative methods for monitoring glycemic control in these patients should be considered. (C) 2008 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:430 / 434
页数:5
相关论文
共 23 条
  • [1] HAEMOGLOBIN VARIANTS AND THEIR INTERFERENCE IN HBA1C DETECTION USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)
    Sosa Moncayo, D.
    Benayas Bellido, P.
    Molina Arrebola, M.
    Gonzalez Raya, A.
    MartinezFernandez, J.
    Avivar Oyonarte, C.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S404 - S404
  • [2] Common Hemoglobin Variants in Southern Taiwan and Their Effect on the Determination of HbA1c by Ion-exchange High-performance Liquid Chromatography
    Chu, Chih-Hsun
    Lam, Hing-Chung
    Lee, Jenn-Kuen
    Wang, Mei-Chun
    Lu, Chih-Chen
    Sun, Chun-Chin
    Chuang, Ming-Ju
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2009, 72 (07) : 362 - 367
  • [3] Verification of the interchangeability of glycosylated hemoglobin results (% HBA1C) by high performance liquid chromatography (HPLC)
    Tejedor Ganduxe, X.
    Minchinela Girona, J.
    Granada Ibern, M.
    Martinez De Osaba, J. Barallat
    Leis Sestao, A.
    Martinez Iribarren, A.
    Morales Indiano, C.
    Llopis Diaz, M.
    CLINICA CHIMICA ACTA, 2019, 493 : S659 - S659
  • [4] Interference of labile glycated hemoglobin on HbA1c assay by a high pressure liquid chromatography method
    Szymezak, J.
    Leroy, N.
    Lavalard, E.
    Gillery, P.
    ANNALES DE BIOLOGIE CLINIQUE, 2008, 66 (04) : 459 - 463
  • [5] INCIDENCE AND INTERFERENCE OF HEMOGLOBIN VARIANTS ON HBA1C MEASUREMENT USING HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY AND CAPILLARY ELECTROPHORESIS
    Van den Bossche, Jan
    Asselman, Valerie
    Luyckx, Kim
    De Block, Christophe
    Van Gaal, Luc
    Van Hoof, Viviane
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2016, 38 : 111 - 111
  • [6] Method comparison of Particle Enhanced Immunoturbidimetry (PEIT) with High Performance Liquid Chromatography (HPLC) for glycated hemoglobin (HbA1c) analysis
    Shabnam Dildar
    Sheharbano Imran
    Farah Naz
    Clinical Diabetes and Endocrinology, 7 (1):
  • [7] The comparison of ion exchange-high performance liquid chromatography (IE-HPLC) and capillary electrophoresis (CE) for HbA1C measurement
    Sutrisnani, Catur Suci
    Darmawan, Edwin
    Widijanti, Anik
    Soehita, Sidarti
    BALI MEDICAL JOURNAL, 2019, 8 (02) : 316 - 322
  • [8] Comparison of two different device results measuring HbA1c by high performance liquid chromatography (HPLC) method
    Gurpinar, Ahmet Burak
    Cihan, Murat
    Noyan, Tevfik
    Demirhan, Erhan Seyfi
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2024, 15 (05): : 313 - 317
  • [9] Comparison of HbA1c detection in whole blood and dried blood spots using an automated ion-exchange HPLC system
    Maleska, Aleksandra
    Hirtz, Christophe
    Casteleyn, Elise
    Villard, Orianne
    Ducos, Jacques
    Avignon, Antoine
    Sultan, Ariane
    Lehmann, Sylvain
    BIOANALYSIS, 2017, 9 (05) : 427 - 434
  • [10] Effect of hemoglobin Porto Alegre on glycated hemoglobin (HbA1c) measurement with the HA-8160 high performance liquid chromatography method
    Lorenzo-Medina, Mercedes
    De-La-Iglesia, Silvia
    Ropero, Paloma
    Martin-Aguila, Adys
    Ruiz-Garcia, Lidia
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (10) : E247 - E249