Interference of hemoglobinA1c (HbA1c) detection using ion-exchange high performance liquid chromatography (HPLC) method by clinically silent hemoglobin variant in University Malaya Medical Centre (UMMC)-A case report

被引:26
|
作者
Thevarajah, M. [1 ]
Nadzirnah, M. N. [1 ]
Chew, Y. Y. [2 ]
机构
[1] Univ Malaya, Med Ctr, Dept Pathol, Fac Med, Kuala Lumpur 50903, Malaysia
[2] Univ Malaya, Med Ctr, Clin Diagnost Lab, Kuala Lumpur 50903, Malaysia
关键词
HbA1c; Hemoglobin variants; Ion-exchange HPLC; HBA(1C); PROGRAM;
D O I
10.1016/j.clinbiochem.2008.10.015
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Glycated hemoglobin, measured as HbA1c is used as an index of mean glycemia in diabetic patients over the preceding 23 months. Various assay methods are used to measure HbA1c and many factors may interfere with its measurement according to assay method used, causing falsely high or low results. Objective: To report a case of diabetic patient with clinically silent hemoglobin variant, causing undetectable HbA1c concentration using ion-exchange high performance liquid chromatography (HPLC) method. Case summary: Our patient is a 65-year-old female with type 2 diabetes mellitus oil diet control. hypertension and hypercholesterolemia. Her fasting blood glucose concentrations ranged from 6.2 to 7.8 mmol/L. Her HbA1c concentrations measured with immunoturbidimetry method (Cobas Integra, Roche Diagnostics) ranged from 6.11 to 7.23%, but were undetectable when measured with ion-exchange HPLC [Arkray HA8160, Diabetes Mode (also known as Menarini HA8160)]. Hemoglobin analysis identified the presence of a hemoglobin variant Hemoglobin D Punjab. Conclusions: Clinical laboratories should be aware of limitations of the HbA1c assay method used, Such as potential interference with hemoglobin variant as depicted by our case. Alternative methods for monitoring glycemic control in these patients should be considered. (C) 2008 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:430 / 434
页数:5
相关论文
共 23 条
  • [21] Hb Aalesund (HBA2: c.400_406delAGCACCG), an Unstable α-Globin Variant Found in a Norwegian Patient Causing Moderate Hemolytic Anemia and Falsely High Hb A1c Using Ion Exchange High Performance Liquid Chromatography
    Grimholt, Runa M.
    Fjeld, Bente
    Selsas, Hilde
    Schwettmann, Lutz
    Klingenberg, Olav
    HEMOGLOBIN, 2019, 43 (02) : 122 - 125
  • [22] Hb A2-Calderdale [δ2(NA2)His→Asn; HBD: c.7C>A] and Misdiagnosis of Type 2 Diabetes Mellitus Due to Interference with Hb A1c When Using Cation Exchange High Performance Liquid Chromatography: A Case Report
    Stangerup, Ida
    Petersen, Jesper
    Glenthoj, Andreas
    HEMOGLOBIN, 2021, 45 (03) : 207 - 209
  • [23] Hb Belluno [β111(G13) Val→Gly;β133(H11) Vall→Val (HBB: c.335T>G;402G>C)]: Incidental Detection of a New Clinically Silent β Chain Variant During Hb A1c Determination by High Performance Liquid Chromatography
    Pianezze, Graziano
    Toniolo, Manuele
    Masieri, Marina Taddei
    Dolcini, Bernardetta
    Ravani, Anna
    HEMOGLOBIN, 2016, 40 (03) : 143 - 149