Modified carbon paste electrodes for flow injection amperometric determination of isocitrate dehydrogenase activity in serum

被引:4
|
作者
Rodríguez-Granda, P [1 ]
Lobo-Castañón, MJ [1 ]
Miranda-Ordieres, AJ [1 ]
Tuñón-Blanco, P [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, E-33006 Oviedo, Spain
关键词
serum isocitrate dehydrogenase activity; flow injection analysis; NADPH; modified electrode; electrocatalysis;
D O I
10.1016/S0003-2697(02)00263-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A carbon paste electrode modified with the adsorbed products of the electrochemical oxidation of adenosine triphosphate is described. The electrode was applied to the amperometric electrocatalytic detection of the reduced form of both nicotinamide adenine dinucleotide and nicotinamide adenine dinucleotide phosphate. The catalytic oxidation current shows a linear dependence on the concentration of the reduced form of nicotinamide adenine dinucleotide up to 1 x 10(-4)M, with a detection limit of 5 x 10(-9)M. Modified carbon paste electrodes were coated with an electrogenerated film of nonconducting poly(o-phenylenediamine) to obtain a stable amperometric response for at least 150 h. In addition to static measurements, determination of both reduced cofactors was carried out in a flow injection analysis system with a thin-layer amperometric detection cell. The electrocatalytic monitoring of reduced nicotinamide adenine dinucleotide phosphate was applied to flow injection measurement of isocitrate dehydrogenase activity in serum. The results were in good agreement with those for the standard spectrophotometric test kit. The proposed method consumed less time and reagents and provided better precision than the standard method. (C) 2002 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:195 / 203
页数:9
相关论文
共 50 条
  • [21] Amperometric Cholinesterase Biosensors with Carbon Paste Electrodes Modified with Cobalt Phthalocyanine
    L. G. Shaidarova
    S. A. Ziganshina
    E. P. Medyantseva
    G. K. Budnikov
    Russian Journal of Applied Chemistry, 2004, 77 : 241 - 248
  • [22] Flow injection analysis using carbon film resistor electrodes for amperometric determination of ambroxol
    Felix, Fabiana S.
    Brett, Christopher M. A.
    Angnes, Lucio
    TALANTA, 2008, 76 (01) : 128 - 133
  • [23] Determination of sulfite by pervaporation-flow injection with amperometric detection using copper hexacyanoferrate-carbon nanotube modified carbon paste electrode
    Alamo, Lori Shayne T.
    Tangkuaram, Tanin
    Satienperakul, Sakchai
    TALANTA, 2010, 81 (4-5) : 1793 - 1799
  • [24] Flow Injection Potentiometric Determination of Pancuronium Bromide in Pharmaceutical Preparation and Urine Samples Using Modified Carbon Paste Electrodes
    Zayed, Sayed Imam Mohamed
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2011, 59 (02) : 254 - 259
  • [25] Modified carbon paste electrodes for Cu(II) determination
    Ghaedi, Mehrorang
    Naderi, Sakineh
    Montazerozohori, Morteza
    Sahraei, Reza
    Daneshfar, Ali
    Taghavimoghadam, Narges
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2012, 32 (08): : 2274 - 2279
  • [26] Flow injection-pulse amperometric detection of ephedrine at a cobalt phthalocyanine modified carbon paste electrode
    Cookeas, EG
    Efstathiou, CE
    ANALYST, 2000, 125 (06) : 1147 - 1150
  • [27] ELECTROCATALYSIS AND AMPEROMETRIC DETECTION OF ORGANIC PEROXIDES AT MODIFIED CARBON-PASTE ELECTRODES
    WANG, J
    ANGNES, L
    LIANG, C
    EVANS, O
    TALANTA, 1991, 38 (10) : 1077 - 1081
  • [28] VOLTAMMETRIC DETERMINATION OF CELIPTIUM WITH CARBON PASTE AND LIPID-MODIFIED CARBON PASTE ELECTRODES
    ARCOS, J
    KAUFFMANN, JM
    PATRIARCHE, GJ
    SANCHEZBATANERO, P
    ANALYTICA CHIMICA ACTA, 1990, 236 (02) : 299 - 305
  • [29] Amperometric determination of serum lactate dehydrogenase activity using an ADP-modified graphite electrode
    de los Santos-Alvarez, N
    Lobo-Castañón, MJ
    Miranda-Ordieres, AJ
    Tuñón-Blanco, P
    ANALYTICA CHIMICA ACTA, 2002, 457 (02) : 275 - 284
  • [30] AMPEROMETRIC DETERMINATION OF DOPAMINE ON AN ENZYMATICALLY MODIFIED CARBON-PASTE ELECTRODE
    FORZANI, ES
    RIVAS, GA
    SOLIS, VM
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 382 (1-2): : 33 - 40