Modified carbon paste electrodes for flow injection amperometric determination of isocitrate dehydrogenase activity in serum

被引:4
|
作者
Rodríguez-Granda, P [1 ]
Lobo-Castañón, MJ [1 ]
Miranda-Ordieres, AJ [1 ]
Tuñón-Blanco, P [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, E-33006 Oviedo, Spain
关键词
serum isocitrate dehydrogenase activity; flow injection analysis; NADPH; modified electrode; electrocatalysis;
D O I
10.1016/S0003-2697(02)00263-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A carbon paste electrode modified with the adsorbed products of the electrochemical oxidation of adenosine triphosphate is described. The electrode was applied to the amperometric electrocatalytic detection of the reduced form of both nicotinamide adenine dinucleotide and nicotinamide adenine dinucleotide phosphate. The catalytic oxidation current shows a linear dependence on the concentration of the reduced form of nicotinamide adenine dinucleotide up to 1 x 10(-4)M, with a detection limit of 5 x 10(-9)M. Modified carbon paste electrodes were coated with an electrogenerated film of nonconducting poly(o-phenylenediamine) to obtain a stable amperometric response for at least 150 h. In addition to static measurements, determination of both reduced cofactors was carried out in a flow injection analysis system with a thin-layer amperometric detection cell. The electrocatalytic monitoring of reduced nicotinamide adenine dinucleotide phosphate was applied to flow injection measurement of isocitrate dehydrogenase activity in serum. The results were in good agreement with those for the standard spectrophotometric test kit. The proposed method consumed less time and reagents and provided better precision than the standard method. (C) 2002 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:195 / 203
页数:9
相关论文
共 50 条
  • [31] AMPEROMETRIC CARBON PASTE ENZYME ELECTRODES FOR URIC ACID DETERMINATION WITH DIFFERENT MEDIATORS
    Erden, Pinar Esra
    Pekyardimci, Sule
    Kilic, Esma
    COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 2011, 76 (09) : 1055 - 1073
  • [32] Effects of mediator and paste hydrophobicity on the response of amperometric carbon paste electrodes: Binder paste electrodes
    Narvaez, A
    Parellada, J
    Dominguez, E
    Katakis, I
    QUIMICA ANALITICA, 1996, 15 (01): : 75 - 82
  • [33] Electrochemical Behavior and Determination of Rutin on Modified Carbon Paste Electrodes
    Macikova, Pavla
    Halouzka, Vladimir
    Hrbac, Jan
    Bartak, Petr
    Skopalova, Jana
    SCIENTIFIC WORLD JOURNAL, 2012,
  • [34] A Comparison of Variously Modified Carbon Paste Electrodes for Determination of Rutin
    Macikova, Pavla
    Skopalova, Jana
    MODERN ELECTROCHEMICAL METHODS XXX, 2010, : 101 - 105
  • [35] Pyranose oxidase modified carbon paste electrodes for monosaccharide determination
    Liden, H
    Volc, J
    Marko-Varga, G
    Gorton, L
    ELECTROANALYSIS, 1998, 10 (04) : 223 - 230
  • [36] VOLTAMMETRIC DETERMINATION OF BISMUTH WITH CARBON PASTE ELECTRODES MODIFIED WITH ALKYLMERCAPTANS
    KALCHER, K
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1986, 325 (02): : 186 - 190
  • [37] High sensitivity amperometric and voltammetric determination of persulfate with neutral red/nickel oxide nanowires modified carbon paste electrodes
    Savari, Z.
    Soltanian, S.
    Noorbakhsh, A.
    Salimi, A.
    Najafi, M.
    Servati, P.
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 176 : 335 - 343
  • [38] Quinoprotein glucose dehydrogenase modified thick-film electrodes for the amperometric detection of phenolic compounds in flow injection analysis
    Andreas Rose
    Frieder W. Scheller
    U. Wollenberger
    Dorothea Pfeiffer
    Fresenius' Journal of Analytical Chemistry, 2001, 369 : 145 - 152
  • [39] Quinoprotein glucose dehydrogenase modified thick-film electrodes for the amperometric detection of phenolic compounds in flow injection analysis
    Rose, A
    Scheller, FW
    Wollenberger, U
    Pfeiffer, D
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (02): : 145 - 152
  • [40] Flow injection amperometric sensor with a carbon nanotube modified screen printed electrode for determination of hydroquinone
    Upan, Jantima
    Reanpang, Preeyaporn
    Chailapakul, Orawon
    Jakmunee, Jaroon
    TALANTA, 2016, 146 : 766 - 771