Modified carbon paste electrodes for flow injection amperometric determination of isocitrate dehydrogenase activity in serum

被引:4
|
作者
Rodríguez-Granda, P [1 ]
Lobo-Castañón, MJ [1 ]
Miranda-Ordieres, AJ [1 ]
Tuñón-Blanco, P [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, E-33006 Oviedo, Spain
关键词
serum isocitrate dehydrogenase activity; flow injection analysis; NADPH; modified electrode; electrocatalysis;
D O I
10.1016/S0003-2697(02)00263-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A carbon paste electrode modified with the adsorbed products of the electrochemical oxidation of adenosine triphosphate is described. The electrode was applied to the amperometric electrocatalytic detection of the reduced form of both nicotinamide adenine dinucleotide and nicotinamide adenine dinucleotide phosphate. The catalytic oxidation current shows a linear dependence on the concentration of the reduced form of nicotinamide adenine dinucleotide up to 1 x 10(-4)M, with a detection limit of 5 x 10(-9)M. Modified carbon paste electrodes were coated with an electrogenerated film of nonconducting poly(o-phenylenediamine) to obtain a stable amperometric response for at least 150 h. In addition to static measurements, determination of both reduced cofactors was carried out in a flow injection analysis system with a thin-layer amperometric detection cell. The electrocatalytic monitoring of reduced nicotinamide adenine dinucleotide phosphate was applied to flow injection measurement of isocitrate dehydrogenase activity in serum. The results were in good agreement with those for the standard spectrophotometric test kit. The proposed method consumed less time and reagents and provided better precision than the standard method. (C) 2002 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:195 / 203
页数:9
相关论文
共 50 条
  • [41] A novel palygorskite-modified carbon paste amperometric sensor for catechol determination
    Kong, Yong
    Chen, Xiaohui
    Wang, Wenchang
    Chen, Zhidong
    ANALYTICA CHIMICA ACTA, 2011, 688 (02) : 203 - 207
  • [42] A thionine-modified carbon paste amperometric biosensor for catechol and bisphenol A determination
    Portaccio, M.
    Di Tuoro, D.
    Arduini, F.
    Lepore, M.
    Mita, D. G.
    Diano, N.
    Mita, L.
    Moscone, D.
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (09): : 2003 - 2008
  • [43] Amperometric determination of urea using enzyme-modified carbon paste electrode
    Yang, JK
    Ha, KS
    Baek, HS
    Lee, SS
    Seo, ML
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2004, 25 (10) : 1499 - 1502
  • [44] Amperometric determination of NAD(P)H with peroxidase-based H2O2-sensing electrodes and its application to isocitrate dehydrogenase activity assay in serum
    Kinoshita, H
    Torimura, M
    Yamamoto, K
    Kano, K
    Ikeda, T
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 478 (1-2): : 33 - 39
  • [45] IMMOBILIZED ENZYME CARBON PASTE ELECTRODES AS AMPEROMETRIC SENSORS
    LORENZO, E
    GONZALEZ, E
    PARIENTE, F
    HERNANDEZ, L
    ELECTROANALYSIS, 1991, 3 (4-5) : 319 - 323
  • [46] Flufenamic acid determination in human serum by adsorptive voltammetry with in situ surfactant modified carbon paste electrodes
    Amor-García, I
    Blanco-López, MC
    Lobo-Castañon, MJ
    Miranda-Ordieres, AJ
    Tuñón-Blanco, P
    ELECTROANALYSIS, 2005, 17 (17) : 1555 - 1562
  • [47] Application of Prussian Blue modified carbon electrodes for amperometric detection of amyloid-β peptides by flow injection analysis
    Suprun, Elena V. V.
    Daboss, Elena V. V.
    Pleshakov, Vladislav M. M.
    Radko, Sergey P. P.
    Karyakin, Arkady A. A.
    Kozin, Sergey A. A.
    Makarov, Alexander A. A.
    Mitkevich, Vladimir A. A.
    Vokhmyanina, Darya V.
    ELECTROCHIMICA ACTA, 2022, 406
  • [48] Amperometric detection of hydrazine by cyclic voltammetry and flow injection analysis using ruthenium modified glassy carbon electrodes
    Pinter, Jill S.
    Brown, Kenneth L.
    DeYoung, Paul A.
    Peaslee, Graham F.
    TALANTA, 2007, 71 (03) : 1219 - 1225
  • [49] Determination of roxarsone using carbon paste and amberlite LA2 modified carbon paste electrodes
    Ahamad, R
    Barek, J
    Yusoff, AR
    Sinaga, SM
    Zima, J
    ELECTROANALYSIS, 2000, 12 (15) : 1220 - 1226
  • [50] Determination of esterase activity by flow injection analysis with amperometric detection
    Takamura, K
    Fuse, T
    Kusu, F
    ANALYTICAL SCIENCES, 1996, 12 (02) : 343 - 347