Modified carbon paste electrodes for flow injection amperometric determination of isocitrate dehydrogenase activity in serum

被引:4
|
作者
Rodríguez-Granda, P [1 ]
Lobo-Castañón, MJ [1 ]
Miranda-Ordieres, AJ [1 ]
Tuñón-Blanco, P [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, E-33006 Oviedo, Spain
关键词
serum isocitrate dehydrogenase activity; flow injection analysis; NADPH; modified electrode; electrocatalysis;
D O I
10.1016/S0003-2697(02)00263-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A carbon paste electrode modified with the adsorbed products of the electrochemical oxidation of adenosine triphosphate is described. The electrode was applied to the amperometric electrocatalytic detection of the reduced form of both nicotinamide adenine dinucleotide and nicotinamide adenine dinucleotide phosphate. The catalytic oxidation current shows a linear dependence on the concentration of the reduced form of nicotinamide adenine dinucleotide up to 1 x 10(-4)M, with a detection limit of 5 x 10(-9)M. Modified carbon paste electrodes were coated with an electrogenerated film of nonconducting poly(o-phenylenediamine) to obtain a stable amperometric response for at least 150 h. In addition to static measurements, determination of both reduced cofactors was carried out in a flow injection analysis system with a thin-layer amperometric detection cell. The electrocatalytic monitoring of reduced nicotinamide adenine dinucleotide phosphate was applied to flow injection measurement of isocitrate dehydrogenase activity in serum. The results were in good agreement with those for the standard spectrophotometric test kit. The proposed method consumed less time and reagents and provided better precision than the standard method. (C) 2002 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:195 / 203
页数:9
相关论文
共 50 条
  • [11] ALDOSE DEHYDROGENASE-MODIFIED CARBON-PASTE ELECTRODES AS AMPEROMETRIC ALDOSE SENSORS
    SMOLANDER, M
    MARKOVARGA, G
    GORTON, L
    ANALYTICA CHIMICA ACTA, 1995, 302 (2-3) : 233 - 240
  • [12] A new carbon paste electrode modified with tetrahydroxyanthraquinone: Flow injection amperometric determination of Cr(VI) in water
    Qi, JR
    Li, Z
    Song, WB
    Xu, HD
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (11) : 1455 - 1458
  • [13] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF THIOCYANATE AND SELENOCYANATE AT A COBALT PHTHALOCYANINE MODIFIED CARBON-PASTE ELECTRODE
    COOKEAS, EG
    EFSTATHIOU, CE
    ANALYST, 1994, 119 (07) : 1607 - 1612
  • [14] Carbon paste and PVC electrodes for the flow injection potentiometric determination of dextromethorphan
    Khaled, Elmorsy
    Hassan, H. N. A.
    Mohamed, Gehad G.
    Seleim, A. A.
    TALANTA, 2010, 81 (1-2) : 510 - 515
  • [15] AMPEROMETRIC BIOSENSORS FOR GLUCOSE BASED ON CARBON PASTE MODIFIED ELECTRODES
    AMINE, A
    KAUFFMANN, JM
    PATRIARCHE, GJ
    TALANTA, 1991, 38 (01) : 107 - 110
  • [16] VOLTAMMETRIC AND AMPEROMETRIC DETERMINATION OF DOXORUBICIN USING CARBON PASTE ELECTRODES
    Jemelkova, Zuzana
    Zima, Jiri
    Barek, Jiri
    COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 2009, 74 (10) : 1503 - 1515
  • [17] Amperometric determination of hydrogen peroxide with a manganese dioxide-modified carbon paste electrode using flow injection analysis
    Schachl, K
    Alemu, H
    Kalcher, K
    Jezkova, J
    Svancara, I
    Vytras, K
    ANALYST, 1997, 122 (09) : 985 - 989
  • [18] ALCOHOL DETERMINATION BY MODIFIED CARBON PASTE ELECTRODES
    BILITEWSKI, U
    SCHMID, RD
    BIOSENSORS : APPLICATIONS IN MEDICINE, ENVIRONMENTAL PROTECTION AND PROCESS CONTROL, 1989, 13 : 99 - 102
  • [19] FLOW-INJECTION AMPEROMETRIC DETECTION OF ANILINE WITH A PEROXIDASE MODIFIED CARBON-PASTE ELECTRODE
    DOMINGUEZSANCHEZ, P
    OSULLIVAN, CK
    MIRANDAORDIERES, AJ
    TUNONBLANCO, P
    SMYTH, MR
    ANALYTICA CHIMICA ACTA, 1994, 291 (03) : 349 - 356
  • [20] Amperometric cholinesterase biosensors with carbon paste electrodes modified with cobalt phthalocyanine
    Shaidarova, LG
    Ziganshina, SA
    Medyantseva, EP
    Budnikov, GK
    RUSSIAN JOURNAL OF APPLIED CHEMISTRY, 2004, 77 (02) : 241 - 248