Amperometric determination of hydrogen peroxide with a manganese dioxide-modified carbon paste electrode using flow injection analysis

被引:109
|
作者
Schachl, K
Alemu, H
Kalcher, K
Jezkova, J
Svancara, I
Vytras, K
机构
[1] KARL FRANZENS UNIV GRAZ,INST ANALYT CHEM,A-8010 GRAZ,AUSTRIA
[2] UNIV ADDIS ABABA,DEPT CHEM,ADDIS ABABA,ETHIOPIA
[3] UNIV PARDUBICE,DEPT ANALYT CHEM,CZ-53210 PARDUBICE,CZECH REPUBLIC
关键词
manganese dioxide; hydrogen peroxide; flow injection analysis; amperometry; modified carbon paste electrode;
D O I
10.1039/a701723e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A carbon paste electrode bulk modified with MnO2 was investigated as an amperometric detector for hydrogen peroxide in flow injection analysis (FIA). With an operating potential of +0.46 V versus Ag/AgCl, H2O2 produces catalytic oxidation currents which can be exploited for quantitative determinations. Factors influencing the analytical performance of the electrode, such as paste composition and pH, were studied both for batch voltammetry and for FIA. For the flow system the influence of the injection volume and flow rate were examined. The amperometric signals are linearly proportional to H2O2 concentrations in the range 0.5-350 mg l(-1), showing a detection limit (three times the signal-to-noise ratio) of 45 mu g l(-1).
引用
收藏
页码:985 / 989
页数:5
相关论文
共 50 条
  • [1] Flow injection determination of hydrogen peroxide using a carbon paste electrode modified with a manganese dioxide film
    Schachl, K
    Alemu, H
    Kalcher, K
    Jezkova, J
    Svancara, I
    Vytras, K
    ANALYTICAL LETTERS, 1997, 30 (15) : 2655 - 2673
  • [2] Manganese dioxide-modified carbon paste electrode for voltammetric determination of riboflavin
    Eda Mehmeti
    Dalibor M. Stanković
    Sudkate Chaiyo
    Ľubomir Švorc
    Kurt Kalcher
    Microchimica Acta, 2016, 183 : 1619 - 1624
  • [3] Manganese dioxide-modified carbon paste electrode for voltammetric determination of riboflavin
    Mehmeti, Eda
    Stankovic, Dalibor M.
    Chaiyo, Sudkate
    Svorc, L'ubomir
    Kalcher, Kurt
    MICROCHIMICA ACTA, 2016, 183 (05) : 1619 - 1624
  • [4] Amperometric determination of hydrogen peroxide with a manganese dioxide film-modified screen printed carbon electrode
    Schachl, K
    Alemu, H
    Kalcher, K
    Moderegger, H
    Svancara, I
    Vytras, K
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 362 (02): : 194 - 200
  • [5] Amperometric determination of hydrogen peroxide with a manganese dioxide film-modified screen printed carbon electrode
    Klemens Schachl
    Hailemichael Alemu
    K. Kalcher
    Helmut Moderegger
    Ivan Svancara
    Karel Vytras
    Fresenius' Journal of Analytical Chemistry, 1998, 362 : 194 - 200
  • [6] Flow injection amperometric determination of acetaminophen at a gold nanoparticle modified carbon paste electrode
    Zemin Xu
    Qu Yue
    Zhenjing Zhuang
    Dan Xiao
    Microchimica Acta, 2009, 164 : 387 - 393
  • [7] Flow injection amperometric determination of acetaminophen at a gold nanoparticle modified carbon paste electrode
    Xu, Zemin
    Yue, Qu
    Zhuang, Zhenjing
    Xiao, Dan
    MICROCHIMICA ACTA, 2009, 164 (3-4) : 387 - 393
  • [8] Low-potential amperometric determination of hydrogen peroxide with a carbon paste electrode modified with nanostructured cryptomelane-type manganese oxides
    Lin, YH
    Cui, XL
    Li, LY
    ELECTROCHEMISTRY COMMUNICATIONS, 2005, 7 (02) : 166 - 172
  • [9] An Efficient Amperometric Sensor for Hydrogen Peroxide by Using a Carbon Paste Electrode Modified with Cobalt Impregnated Zeolite
    Norouzi, Banafsheh
    Moradian, Majid
    Malekan, Ali
    PORTUGALIAE ELECTROCHIMICA ACTA, 2015, 33 (02) : 111 - 124
  • [10] A new carbon paste electrode modified with tetrahydroxyanthraquinone: Flow injection amperometric determination of Cr(VI) in water
    Qi, JR
    Li, Z
    Song, WB
    Xu, HD
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (11) : 1455 - 1458