Amperometric determination of hydrogen peroxide with a manganese dioxide-modified carbon paste electrode using flow injection analysis

被引:109
|
作者
Schachl, K
Alemu, H
Kalcher, K
Jezkova, J
Svancara, I
Vytras, K
机构
[1] KARL FRANZENS UNIV GRAZ,INST ANALYT CHEM,A-8010 GRAZ,AUSTRIA
[2] UNIV ADDIS ABABA,DEPT CHEM,ADDIS ABABA,ETHIOPIA
[3] UNIV PARDUBICE,DEPT ANALYT CHEM,CZ-53210 PARDUBICE,CZECH REPUBLIC
关键词
manganese dioxide; hydrogen peroxide; flow injection analysis; amperometry; modified carbon paste electrode;
D O I
10.1039/a701723e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A carbon paste electrode bulk modified with MnO2 was investigated as an amperometric detector for hydrogen peroxide in flow injection analysis (FIA). With an operating potential of +0.46 V versus Ag/AgCl, H2O2 produces catalytic oxidation currents which can be exploited for quantitative determinations. Factors influencing the analytical performance of the electrode, such as paste composition and pH, were studied both for batch voltammetry and for FIA. For the flow system the influence of the injection volume and flow rate were examined. The amperometric signals are linearly proportional to H2O2 concentrations in the range 0.5-350 mg l(-1), showing a detection limit (three times the signal-to-noise ratio) of 45 mu g l(-1).
引用
收藏
页码:985 / 989
页数:5
相关论文
共 50 条
  • [21] Methylene Blue/Multiwall Carbon Nanotube Modified Electrode for the Amperometric Determination of Hydrogen Peroxide
    Pena, Roselyn C.
    Bertotti, Mauro
    Brett, Christopher M. A.
    ELECTROANALYSIS, 2011, 23 (10) : 2290 - 2296
  • [22] FLOW-INJECTION AMPEROMETRIC DETECTION OF ANILINE WITH A PEROXIDASE MODIFIED CARBON-PASTE ELECTRODE
    DOMINGUEZSANCHEZ, P
    OSULLIVAN, CK
    MIRANDAORDIERES, AJ
    TUNONBLANCO, P
    SMYTH, MR
    ANALYTICA CHIMICA ACTA, 1994, 291 (03) : 349 - 356
  • [23] Hydrogen peroxide sensor based on glassy carbon electrode modified with β-manganese dioxide nanorods
    Ai-Jun Wang
    Pei-Pei Zhang
    Yong-Fang Li
    Jiu-Ju Feng
    Wen-Ju Dong
    Xue-Yan Liu
    Microchimica Acta, 2011, 175 : 31 - 37
  • [24] Hydrogen peroxide sensor based on glassy carbon electrode modified with β-manganese dioxide nanorods
    Wang, Ai-Jun
    Zhang, Pei-Pei
    Li, Yong-Fang
    Feng, Jiu-Ju
    Dong, Wen-Ju
    Liu, Xue-Yan
    MICROCHIMICA ACTA, 2011, 175 (1-2) : 31 - 37
  • [25] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF HYDROGEN-PEROXIDE BY OXIDATION AT AN IRIDIUM OXIDE ELECTRODE
    COX, JA
    LEWINSKI, K
    TALANTA, 1993, 40 (12) : 1911 - 1915
  • [26] Chemically Modified Carbon Paste Electrodes for Ascorbic Acid Determination in Soft Drinks by Flow Injection Amperometric Analysis
    Sales, M. Goreti F.
    Castanheira, M. S. A.
    Ferreira, Rosa M. S.
    Vaz, M. Carmo V. F.
    Delerue-Matos, Cristina
    PORTUGALIAE ELECTROCHIMICA ACTA, 2008, 26 (01) : 147 - 157
  • [27] Amperometric determination of hydrogen peroxide residue in beverages using a Nafion modified palladium electrode
    Chuan-Liang Hsu
    Hung-Der Jang
    Ming-Sheng Su
    Ku-Shang Chang
    Yung-Sheng Huang
    European Food Research and Technology, 2008, 226 : 809 - 815
  • [28] Amperometric determination of hydrogen peroxide residue in beverages using a Nafion modified palladium electrode
    Hsu, Chuan-Liang
    Jang, Hung-Der
    Su, Ming-Sheng
    Chang, Ku-Shang
    Huang, Yung-Sheng
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2008, 226 (04) : 809 - 815
  • [29] A glassy carbon electrode modified with graphene oxide and silver nanoparticles for amperometric determination of hydrogen peroxide
    Noor, An'amt Mohamed
    Shahid, Muhammad Mehmood
    Rameshkumar, Perumal
    Huang, Nay Ming
    MICROCHIMICA ACTA, 2016, 183 (02) : 911 - 916
  • [30] Amperometric sensing of hydrogen peroxide using glassy carbon electrode modified with copper nanoparticles
    Sophia, J.
    Muralidharan, G.
    MATERIALS RESEARCH BULLETIN, 2015, 70 : 315 - 320