Determination of sulfite by pervaporation-flow injection with amperometric detection using copper hexacyanoferrate-carbon nanotube modified carbon paste electrode

被引:49
|
作者
Alamo, Lori Shayne T. [1 ,2 ]
Tangkuaram, Tanin [1 ]
Satienperakul, Sakchai [1 ]
机构
[1] Maejo Univ, Fac Sci, Dept Chem, Chiang Mai 50290, Thailand
[2] Nueva Vizcaya State Univ, Dept Chem, Coll Arts & Sci, Bayombong 3700, Nueva Vizcaya, Philippines
关键词
Sulfite; Flow injection; Pervaporation; Copper hexacyanoferrate-carbon nanotube modified carbon paste electrode; FILM-MODIFIED ELECTRODES; FREE SULFUR-DIOXIDE; COBALT-HEXACYANOFERRATE; GAS-DIFFUSION; ELECTROCATALYTIC OXIDATION; CHROMIUM HEXACYANOFERRATE; ELECTROCHEMICAL SENSOR; SEQUENTIAL INJECTION; WINE; BIOSENSORS;
D O I
10.1016/j.talanta.2010.03.043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A pervaporation-flow injection (PFI) method was developed for the determination of sulfite in selected food samples using a copper hexacyanoferrate-carbon nanotube (CuHCF-CNT)-modified carbon paste electrode The electrochemical behavior of the modified electrode was observed using cyclic voltammetry in comparison to a CuHCF-modified carbon paste electrode and a bare carbon paste electrode at a scan rate of 100 mVs(-1) in 0 10 M KNO3. The bare carbon paste electrode gave the lowest response to sulfite, while the presence of CuHCF made the detection of sulfite possible through electrocatalytic oxidation by the hexacyanoferrate in the modified electrodes The presence of CNT in the CuHCF-CNT-modified sensor gave the most remarkable current for the detection of sulfite and was then used as a working electrode in the amperometric flow-through cell in the pervaporation flow injection system The PFI method involves the injection of a standard or sample sulfite solution into a sulfuric acid donor stream to generate sulfur dioxide gas and evaporate into the headspace of the pervaporation unit. The sulfur dioxide diffuses through the PTFE hydrophobic membrane Into a potassium nitrate acceptor stream and reverts to the sulfite form, which, subsequently, is transported to the electrochemical flow cell where it is analyzed amperometrically at a CuHCF-CNT-modified electrode at +055 V (vs. Ag/AgCl) The detection was determined to be applicable in the sulfite concentration range of 0.5-50 mg L-1. The sensitivity, detection limit. and sample throughput were determined to be 2.105 nA L mg(-1), 0.40 mg L-1 and 11 h(-1). respectively. The developed PFI method. coupled with the CuHCF-CNT-modified carbon paste electrode. was applied in the determination of sulfite content in sulfite-containing food products The results agreed well with those obtained through the officially recommended differential pulse polarographic method. (C) 2010 Elsevier B.V All rights reserved
引用
收藏
页码:1793 / 1799
页数:7
相关论文
共 50 条
  • [1] Electrocatalytic Oxidation and Determination of Sulfite with a Novel Copper-Cobalt Hexacyanoferrate Modified Carbon Paste Electrode
    Siroueinejad, Arash
    Abbaspour, Abdolkarim
    Shamsipur, Mojtaba
    ELECTROANALYSIS, 2009, 21 (12) : 1387 - 1393
  • [2] Flow injection amperometric determination of acetaminophen at a gold nanoparticle modified carbon paste electrode
    Zemin Xu
    Qu Yue
    Zhenjing Zhuang
    Dan Xiao
    Microchimica Acta, 2009, 164 : 387 - 393
  • [3] Flow injection amperometric determination of acetaminophen at a gold nanoparticle modified carbon paste electrode
    Xu, Zemin
    Yue, Qu
    Zhuang, Zhenjing
    Xiao, Dan
    MICROCHIMICA ACTA, 2009, 164 (3-4) : 387 - 393
  • [4] Simultaneous Determination of Phenylhydrazine, Hydrazine and Sulfite Using a Modified Carbon Nanotube Paste Electrode
    Rastakhiz, Nahid
    Kariminik, Ashraf
    Soltani-Nejad, Vahhab
    Roodsaz, Sara
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (09): : 1203 - 1212
  • [5] Simple flow injection for determination of sulfite by amperometric detection using glassy carbon electrode modified with carbon nanotubes-PDDA-gold nanoparticles
    Amatatongchai, Maliwan
    Sroysee, Wongduan
    Chairam, Sanoe
    Nacapricha, Duangjai
    TALANTA, 2015, 133 : 134 - 141
  • [6] Chemically modified multiwalled carbon nanotube carbon paste electrode for copper determination
    Ghaedi, M.
    Naderi, S.
    Montazerozohori, M.
    Taghizadeh, F.
    Asghari, A.
    ARABIAN JOURNAL OF CHEMISTRY, 2017, 10 : S2934 - S2943
  • [7] FLOW-INJECTION AMPEROMETRIC DETECTION OF ANILINE WITH A PEROXIDASE MODIFIED CARBON-PASTE ELECTRODE
    DOMINGUEZSANCHEZ, P
    OSULLIVAN, CK
    MIRANDAORDIERES, AJ
    TUNONBLANCO, P
    SMYTH, MR
    ANALYTICA CHIMICA ACTA, 1994, 291 (03) : 349 - 356
  • [8] Flow injection amperometric sensor with a carbon nanotube modified screen printed electrode for determination of hydroquinone
    Upan, Jantima
    Reanpang, Preeyaporn
    Chailapakul, Orawon
    Jakmunee, Jaroon
    TALANTA, 2016, 146 : 766 - 771
  • [9] Nile Blue-hexacyanoferrate carbon paste modified electrode as an amperometric sensor for determination of hydrazine
    Sabzi, Reza Emamali
    Minaie, Elnaz
    Farhadi, Khalil
    Golzan, Mir Maqsoud
    TURKISH JOURNAL OF CHEMISTRY, 2010, 34 (06) : 901 - 910
  • [10] Determination of trace copper by adsorptive voltammetry using a multiwalled carbon nanotube modified carbon paste electrode
    Deng, Peihong
    Fei, Junjie
    Zhang, Jun
    Li, Junan
    ELECTROANALYSIS, 2008, 20 (11) : 1215 - 1219