Determination of sulfite by pervaporation-flow injection with amperometric detection using copper hexacyanoferrate-carbon nanotube modified carbon paste electrode

被引:49
|
作者
Alamo, Lori Shayne T. [1 ,2 ]
Tangkuaram, Tanin [1 ]
Satienperakul, Sakchai [1 ]
机构
[1] Maejo Univ, Fac Sci, Dept Chem, Chiang Mai 50290, Thailand
[2] Nueva Vizcaya State Univ, Dept Chem, Coll Arts & Sci, Bayombong 3700, Nueva Vizcaya, Philippines
关键词
Sulfite; Flow injection; Pervaporation; Copper hexacyanoferrate-carbon nanotube modified carbon paste electrode; FILM-MODIFIED ELECTRODES; FREE SULFUR-DIOXIDE; COBALT-HEXACYANOFERRATE; GAS-DIFFUSION; ELECTROCATALYTIC OXIDATION; CHROMIUM HEXACYANOFERRATE; ELECTROCHEMICAL SENSOR; SEQUENTIAL INJECTION; WINE; BIOSENSORS;
D O I
10.1016/j.talanta.2010.03.043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A pervaporation-flow injection (PFI) method was developed for the determination of sulfite in selected food samples using a copper hexacyanoferrate-carbon nanotube (CuHCF-CNT)-modified carbon paste electrode The electrochemical behavior of the modified electrode was observed using cyclic voltammetry in comparison to a CuHCF-modified carbon paste electrode and a bare carbon paste electrode at a scan rate of 100 mVs(-1) in 0 10 M KNO3. The bare carbon paste electrode gave the lowest response to sulfite, while the presence of CuHCF made the detection of sulfite possible through electrocatalytic oxidation by the hexacyanoferrate in the modified electrodes The presence of CNT in the CuHCF-CNT-modified sensor gave the most remarkable current for the detection of sulfite and was then used as a working electrode in the amperometric flow-through cell in the pervaporation flow injection system The PFI method involves the injection of a standard or sample sulfite solution into a sulfuric acid donor stream to generate sulfur dioxide gas and evaporate into the headspace of the pervaporation unit. The sulfur dioxide diffuses through the PTFE hydrophobic membrane Into a potassium nitrate acceptor stream and reverts to the sulfite form, which, subsequently, is transported to the electrochemical flow cell where it is analyzed amperometrically at a CuHCF-CNT-modified electrode at +055 V (vs. Ag/AgCl) The detection was determined to be applicable in the sulfite concentration range of 0.5-50 mg L-1. The sensitivity, detection limit. and sample throughput were determined to be 2.105 nA L mg(-1), 0.40 mg L-1 and 11 h(-1). respectively. The developed PFI method. coupled with the CuHCF-CNT-modified carbon paste electrode. was applied in the determination of sulfite content in sulfite-containing food products The results agreed well with those obtained through the officially recommended differential pulse polarographic method. (C) 2010 Elsevier B.V All rights reserved
引用
收藏
页码:1793 / 1799
页数:7
相关论文
共 50 条
  • [41] Flow injection determination of hydrogen peroxide using a carbon paste electrode modified with a manganese dioxide film
    Schachl, K
    Alemu, H
    Kalcher, K
    Jezkova, J
    Svancara, I
    Vytras, K
    ANALYTICAL LETTERS, 1997, 30 (15) : 2655 - 2673
  • [42] Simple flow injection for screening of total antioxidant capacity by amperometric detection of DPPH radical on carbon nanotube modified-glassy carbon electrode
    Amatatongchai, M.
    Laosing, S.
    Chailapakul, O.
    Nacapricha, D.
    TALANTA, 2012, 97 : 267 - 272
  • [43] Naphthazarin modified carbon paste electrode for determination of copper(II)
    Chaisuksant, Rasamee
    Pattanarat, Lertnapa
    Grudpan, Kate
    MICROCHIMICA ACTA, 2008, 162 (1-2) : 181 - 188
  • [44] Naphthazarin modified carbon paste electrode for determination of copper(II)
    Rasamee Chaisuksant
    Lertnapa Pattanarat
    Kate Grudpan
    Microchimica Acta, 2008, 162 : 181 - 188
  • [45] DETERMINATION OF PENTACHLOROPHENOL BY FLOW-INJECTION AND AMPEROMETRIC DETECTION WITH A GLASSY-CARBON ELECTRODE
    YANEZSEDENO, P
    GUIJARRO, EC
    CARRAZON, JMP
    DIEZ, LMP
    MICROCHEMICAL JOURNAL, 1990, 41 (03) : 366 - 371
  • [46] Electrocatalytic oxidation of captopril using a carbon-paste electrode modified with copper-cobalt hexacyanoferrate
    Jalali, Fahimeh
    Ranjbar, Sedigheh
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2014, 50 (05) : 482 - 489
  • [47] Voltammetric determination of norepinephrine in the presence of tryptophan using a modified carbon nanotube paste electrode
    Anis Hosseini
    Mohammad Ali Taher
    Hadi Beitollahi
    Research on Chemical Intermediates, 2015, 41 : 5995 - 6007
  • [48] Voltammetric determination of norepinephrine in the presence of tryptophan using a modified carbon nanotube paste electrode
    Hosseini, Anis
    Taher, Mohammad Ali
    Beitollahi, Hadi
    RESEARCH ON CHEMICAL INTERMEDIATES, 2015, 41 (09) : 5995 - 6007
  • [49] Electrocatalytic oxidation of captopril using a carbon-paste electrode modified with copper-cobalt hexacyanoferrate
    Fahimeh Jalali
    Sedigheh Ranjbar
    Russian Journal of Electrochemistry, 2014, 50 : 482 - 489
  • [50] Electrocatalytic amperometric determination of amitrole using a cobalt-phthalocyanine-modified carbon paste electrode
    Manuel Chicharro
    Antonio Zapardiel
    Esperanza Bermejo
    Mónica Moreno
    Elena Madrid
    Analytical and Bioanalytical Chemistry, 2002, 373 : 277 - 283