Determination of sulfite by pervaporation-flow injection with amperometric detection using copper hexacyanoferrate-carbon nanotube modified carbon paste electrode

被引:49
|
作者
Alamo, Lori Shayne T. [1 ,2 ]
Tangkuaram, Tanin [1 ]
Satienperakul, Sakchai [1 ]
机构
[1] Maejo Univ, Fac Sci, Dept Chem, Chiang Mai 50290, Thailand
[2] Nueva Vizcaya State Univ, Dept Chem, Coll Arts & Sci, Bayombong 3700, Nueva Vizcaya, Philippines
关键词
Sulfite; Flow injection; Pervaporation; Copper hexacyanoferrate-carbon nanotube modified carbon paste electrode; FILM-MODIFIED ELECTRODES; FREE SULFUR-DIOXIDE; COBALT-HEXACYANOFERRATE; GAS-DIFFUSION; ELECTROCATALYTIC OXIDATION; CHROMIUM HEXACYANOFERRATE; ELECTROCHEMICAL SENSOR; SEQUENTIAL INJECTION; WINE; BIOSENSORS;
D O I
10.1016/j.talanta.2010.03.043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A pervaporation-flow injection (PFI) method was developed for the determination of sulfite in selected food samples using a copper hexacyanoferrate-carbon nanotube (CuHCF-CNT)-modified carbon paste electrode The electrochemical behavior of the modified electrode was observed using cyclic voltammetry in comparison to a CuHCF-modified carbon paste electrode and a bare carbon paste electrode at a scan rate of 100 mVs(-1) in 0 10 M KNO3. The bare carbon paste electrode gave the lowest response to sulfite, while the presence of CuHCF made the detection of sulfite possible through electrocatalytic oxidation by the hexacyanoferrate in the modified electrodes The presence of CNT in the CuHCF-CNT-modified sensor gave the most remarkable current for the detection of sulfite and was then used as a working electrode in the amperometric flow-through cell in the pervaporation flow injection system The PFI method involves the injection of a standard or sample sulfite solution into a sulfuric acid donor stream to generate sulfur dioxide gas and evaporate into the headspace of the pervaporation unit. The sulfur dioxide diffuses through the PTFE hydrophobic membrane Into a potassium nitrate acceptor stream and reverts to the sulfite form, which, subsequently, is transported to the electrochemical flow cell where it is analyzed amperometrically at a CuHCF-CNT-modified electrode at +055 V (vs. Ag/AgCl) The detection was determined to be applicable in the sulfite concentration range of 0.5-50 mg L-1. The sensitivity, detection limit. and sample throughput were determined to be 2.105 nA L mg(-1), 0.40 mg L-1 and 11 h(-1). respectively. The developed PFI method. coupled with the CuHCF-CNT-modified carbon paste electrode. was applied in the determination of sulfite content in sulfite-containing food products The results agreed well with those obtained through the officially recommended differential pulse polarographic method. (C) 2010 Elsevier B.V All rights reserved
引用
收藏
页码:1793 / 1799
页数:7
相关论文
共 50 条
  • [21] Voltammetric determination of N-acetylcysteine using a carbon paste electrode modified with copper(II) hexacyanoferrate(III)
    Suarez, WT
    Marcolino, LH
    Fatibello, O
    MICROCHEMICAL JOURNAL, 2006, 82 (02) : 163 - 167
  • [22] Voltammetric determination of isoprenaline in pharmaceutical preparations using a copper(II) hexacyanoferrate(III) modified carbon paste electrode
    Bonifácio, VG
    Marcolino, LH
    Teixeira, MFS
    Fatibello-Filho, O
    MICROCHEMICAL JOURNAL, 2004, 78 (01) : 55 - 59
  • [23] Voltammetric determination of copper in water samples using a Schiff base/carbon nanotube-modified carbon paste electrode
    Izadkhah, V.
    Farmany, A.
    Mortazavi, S. S.
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2015, 21 : 994 - 996
  • [24] Electrocatalytic determination of sulfite using a modified carbon nanotubes paste electrode: application for determination of sulfite in real samples
    Hassan Karimi-Maleh
    Ali A. Ensafi
    Hadi Beitollahi
    Vahid Nasiri
    Mohammad A. Khalilzadeh
    Pourya Biparva
    Ionics, 2012, 18 : 687 - 694
  • [25] Electrocatalytic determination of sulfite using a modified carbon nanotubes paste electrode: application for determination of sulfite in real samples
    Karimi-Maleh, Hassan
    Ensafi, Ali A.
    Beitollahi, Hadi
    Nasiri, Vahid
    Khalilzadeh, Mohammad A.
    Biparva, Pourya
    IONICS, 2012, 18 (07) : 687 - 694
  • [26] Determination of Benzocaine Using HPLC and FIA with Amperometric Detection on a Carbon Paste Electrode
    Dejmkova, Hana
    Vokalova, Veronika
    Zima, Jiri
    Barek, Jiri
    ELECTROANALYSIS, 2011, 23 (03) : 662 - 666
  • [27] Flow Injection Amperometric Detection of Sulfide Using a Prussian Blue Modified Glassy Carbon Electrode
    Bensu Ertek
    Dai Long Vu
    Libor Červenka
    Yusuf Dilgin
    Analytical Sciences, 2012, 28 : 1075 - 1080
  • [28] Flow Injection Amperometric Detection of Sulfide Using a Prussian Blue Modified Glassy Carbon Electrode
    Ertek, Bensu
    Vu, Dai Long
    Cervenka, Libor
    Dilgin, Yusuf
    ANALYTICAL SCIENCES, 2012, 28 (11) : 1075 - 1080
  • [29] Amperometric Detection of Ranitidine Using Glassy Carbon Modified with Ruthenium Oxide Hexacyanoferrate Adapted in a Flow Injection System
    de Araujo, William R.
    Paixao, Thiago R. L. C.
    ELECTROANALYSIS, 2011, 23 (11) : 2549 - 2554
  • [30] FLOW-INJECTION DETERMINATION OF NOVALGIN USING AMPEROMETRIC DETECTION AT A GLASSY-CARBON ELECTRODE
    PEREZRUIZ, T
    LOZANO, CM
    TOMAS, V
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (09) : 1109 - 1113