Characterization of proton pencil beam scanning and passive beam using a high spatial resolution solid-state microdosimeter

被引:56
|
作者
Tran, Linh T. [1 ]
Chartier, Lachlan [1 ]
Bolst, David [1 ]
Pogossov, Alex [1 ]
Guatelli, Susanna [1 ]
Petasecca, Marco [1 ]
Lerch, Michael L. F. [1 ]
Prokopovich, Dale A. [2 ]
Reinhard, Mark I. [2 ]
Clasie, Benjamin [3 ]
Depauw, Nicolas [3 ]
Kooy, Hanne [3 ]
Flanz, Jacob B. [3 ]
McNamara, Aimee [3 ]
Paganetti, Harald [3 ]
Beltran, Chris [4 ]
Furutani, Keith [4 ]
Perevertaylo, Vladimir L. [5 ]
Jackson, Michael [6 ]
Rosenfeld, Anatoly B. [1 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[2] Australian Nucl Sci & Technol Org, Lucas Heights, Australia
[3] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[4] Mayo Clin, Radiat Oncol, Rochester, MN USA
[5] SPA BIT, Kiev, Ukraine
[6] Prince Wales Hosp, Dept Radiat Oncol, Randwick, NSW 2031, Australia
基金
澳大利亚研究理事会;
关键词
3D sensitive volume; microdosimetry; pencil beam scanning (PBS); proton therapy; RBE; silicon on insulator (SOI); RELATIVE BIOLOGICAL EFFECTIVENESS; RADIATION-FIELDS; CELL-SURVIVAL; C-12; ION; RBE; SILICON; MODEL;
D O I
10.1002/mp.12563
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This work aims to characterize a proton pencil beam scanning (PBS) and passive double scattering (DS) systems as well as to measure parameters relevant to the relative biological effectiveness (RBE) of the beam using a silicon on insulator (SOI) microdosimeter with well-defined 3D sensitive volumes (SV). The dose equivalent downstream and laterally outside of a clinical PBS treatment field was assessed and compared to that of a DS beam. Methods: A novel silicon microdosimeter with well-defined 3D SVs was used in this study. It was connected to low noise electronics, allowing for detection of lineal energies as low as 0.15keV/m. The microdosimeter was placed at various depths in a water phantom along the central axis of the proton beam, and at the distal part of the spread-out Bragg peak (SOBP) in 0.5mm increments. The RBE values of the pristine Bragg peak (BP) and SOBP were derived using the measured microdosimetric lineal energy spectra as inputs to the modified microdosimetric kinetic model (MKM). Geant4 simulations were performed in order to verify the calculated depth-dose distribution from the treatment planning system (TPS) and to compare the simulated dose-mean lineal energy to the experimental results. Results: For a 131MeV PBS spot (124.6mm R-90 range in water), the measured dose-mean lineal energy (y(D)) over bar increased from 2 keV/mu m at the entrance to 8keV/m in the BP, with a maximum value of 10 keV/mu m at the distal edge. The derived RBE distribution for the PBS beam slowly increased from 0.970.14 at the entrance to 1.04 +/- 0.09 proximal to the BP, then to 1.1 +/- 0.08 in the BP, and steeply rose to 1.57 +/- 0.19 at the distal part of the BP. The RBE distribution for the DS SOBP beam was approximately 0.96 +/- 0.16 to 1.01 +/- 0.16 at shallow depths, and 1.01 +/- 0.16 to 1.28 +/- 0.17 within the SOBP. The RBE significantly increased from 1.29 +/- 0.17 to 1.43 +/- 0.18 at the distal edge of the SOBP. Conclusions: The SOI microdosimeter with its well-defined 3D SV has applicability in characterizing proton radiation fields and can measure relevant physical parameters to model the RBE with submillimeter spatial resolution. It has been shown that for a physical dose of 1.82Gy at the BP, the derived RBE based on the MKM model increased from 1.14 to 1.6 in the BP and its distal part. Good agreement was observed between the experimental and simulation results, confirming the potential application of SOI microdosimeter with 3D SV for quality assurance in proton therapy. (C) 2017 American Association of Physicists in Medicine
引用
收藏
页码:6085 / 6095
页数:11
相关论文
共 50 条
  • [21] Pencil Beam Scanning Vs. Passive Scattered Proton Therapy for Pediatric Thoracic/pelvic Cancers
    Moteabbed, M.
    Yock, T.
    Paganetti, H.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [22] Treatment Planning of Bulky Tumors Using Pencil Beam Scanning Proton GRID Therapy
    Halthore, Aditya
    Fellows, Zachary
    Tran, Anh
    Deville, Curtiland, Jr.
    Wright, Jean L.
    Meyer, Jeffrey
    Li, Heng
    Sheikh, Khadija
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2023, 9 (03) : 40 - 49
  • [23] Treatment Planning of Bulky Tumors Using Pencil Beam Scanning Proton GRID Therapy
    Halthore, Aditya
    Fellows, Zachary
    Tran, Anh
    Deville Jr, Curtiland
    Wright, Jean L.
    Meyer, Jeffrey
    Li, Heng
    Sheikh, Khadija
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2022,
  • [24] Treatment of a Pregnant Patient With a Brain Tumor Using Pencil Beam Scanning Proton Therapy
    Dupere, Justine M.
    Breen, William G.
    Lucido, John J.
    Remmes, Nicholas B.
    ADVANCES IN RADIATION ONCOLOGY, 2025, 10 (01)
  • [25] High spatiotemporal resolution scintillation imaging of pulsed pencil beam scanning proton beams produced by a gantry-mounted synchrocyclotron
    Goddu, S. Murty
    Hao, Yao
    Ji, Zhen
    Setianegara, Jufri
    Liu, Fengwei
    Green, Winter
    Sobotka, Lee G.
    Zhao, Tianyu
    Perkins, Stephanie
    Darafsheh, Arash
    MEDICAL PHYSICS, 2024, 51 (07) : 4996 - 5006
  • [26] A 2D strip ionization chamber array with high spatiotemporal resolution for proton pencil beam scanning FLASH radiotherapy
    Yang, Yunjie
    Shi, Chengyu
    Chen, Chin-Cheng
    Tsai, Pingfang
    Kang, Minglei
    Huang, Sheng
    Lin, Chih-Hsun
    Chang, Fu-Xiong
    Chhabra, Arpit M.
    Choi, J. Isabelle
    Tome, Wolfgang A.
    Simone, Charles B.
    Lin, Haibo
    MEDICAL PHYSICS, 2022, 49 (08) : 5464 - 5475
  • [27] A High Spatiotemporal Resolution 2D Strip Ionization Chamber Array for Proton Pencil Beam Scanning FLASH Radiotherapy
    Yang, Y.
    Shi, C.
    Chen, C.
    Tsai, P.
    Huang, S.
    Kang, M.
    Lin, C.
    Chang, F.
    Chhabra, A.
    Choi, I.
    Tome, W.
    Simone, C.
    Lin, H.
    MEDICAL PHYSICS, 2022, 49 (06) : E520 - E520
  • [28] Passive Scattering to Pencil-Beam-Scanning Comparison for Medulloblastoma Proton Therapy: LET Distributions and Radiobiological Implications
    Giantsoudi, D.
    MacDonald, S.
    Paganetti, H.
    MEDICAL PHYSICS, 2014, 41 (06) : 311 - 311
  • [29] Relative biological effectiveness (RBE) and out-of-field cell survival responses to passive scattering and pencil beam scanning proton beam deliveries
    Butterworth, Karl T.
    McGarry, Conor K.
    Clasie, Ben
    Carabe-Fernandez, Alejandro
    Schuemann, Jan
    Depauw, Nicolas
    Tang, Shikui
    McMahon, Stephen J.
    Schettino, Giuseppe
    O'Sullivan, Joe M.
    Lu, Hsaio-Ming
    Kooy, Hanne
    Paganetti, Harald
    Hounsell, Alan R.
    Held, Kathryn D.
    Prise, Kevin M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (20): : 6671 - 6680
  • [30] Proton beam therapy delivered using pencil beam scanning vs. passive scattering/uniform scanning for localized prostate cancer: Comparative toxicity analysis of PCG 001-09
    Mishra, Mark, V
    Khairnar, Rahul
    Bentzen, Soren M.
    Larson, Gary
    Tsai, Henry
    Sinesi, Christopher
    Vargas, Carlos
    Laramore, George
    Rossi, Carl
    Rosen, Lane
    Zhu, Mingyao
    Hartsell, William
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2019, 19 : 80 - 86