Characterization of proton pencil beam scanning and passive beam using a high spatial resolution solid-state microdosimeter

被引:56
|
作者
Tran, Linh T. [1 ]
Chartier, Lachlan [1 ]
Bolst, David [1 ]
Pogossov, Alex [1 ]
Guatelli, Susanna [1 ]
Petasecca, Marco [1 ]
Lerch, Michael L. F. [1 ]
Prokopovich, Dale A. [2 ]
Reinhard, Mark I. [2 ]
Clasie, Benjamin [3 ]
Depauw, Nicolas [3 ]
Kooy, Hanne [3 ]
Flanz, Jacob B. [3 ]
McNamara, Aimee [3 ]
Paganetti, Harald [3 ]
Beltran, Chris [4 ]
Furutani, Keith [4 ]
Perevertaylo, Vladimir L. [5 ]
Jackson, Michael [6 ]
Rosenfeld, Anatoly B. [1 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[2] Australian Nucl Sci & Technol Org, Lucas Heights, Australia
[3] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[4] Mayo Clin, Radiat Oncol, Rochester, MN USA
[5] SPA BIT, Kiev, Ukraine
[6] Prince Wales Hosp, Dept Radiat Oncol, Randwick, NSW 2031, Australia
基金
澳大利亚研究理事会;
关键词
3D sensitive volume; microdosimetry; pencil beam scanning (PBS); proton therapy; RBE; silicon on insulator (SOI); RELATIVE BIOLOGICAL EFFECTIVENESS; RADIATION-FIELDS; CELL-SURVIVAL; C-12; ION; RBE; SILICON; MODEL;
D O I
10.1002/mp.12563
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This work aims to characterize a proton pencil beam scanning (PBS) and passive double scattering (DS) systems as well as to measure parameters relevant to the relative biological effectiveness (RBE) of the beam using a silicon on insulator (SOI) microdosimeter with well-defined 3D sensitive volumes (SV). The dose equivalent downstream and laterally outside of a clinical PBS treatment field was assessed and compared to that of a DS beam. Methods: A novel silicon microdosimeter with well-defined 3D SVs was used in this study. It was connected to low noise electronics, allowing for detection of lineal energies as low as 0.15keV/m. The microdosimeter was placed at various depths in a water phantom along the central axis of the proton beam, and at the distal part of the spread-out Bragg peak (SOBP) in 0.5mm increments. The RBE values of the pristine Bragg peak (BP) and SOBP were derived using the measured microdosimetric lineal energy spectra as inputs to the modified microdosimetric kinetic model (MKM). Geant4 simulations were performed in order to verify the calculated depth-dose distribution from the treatment planning system (TPS) and to compare the simulated dose-mean lineal energy to the experimental results. Results: For a 131MeV PBS spot (124.6mm R-90 range in water), the measured dose-mean lineal energy (y(D)) over bar increased from 2 keV/mu m at the entrance to 8keV/m in the BP, with a maximum value of 10 keV/mu m at the distal edge. The derived RBE distribution for the PBS beam slowly increased from 0.970.14 at the entrance to 1.04 +/- 0.09 proximal to the BP, then to 1.1 +/- 0.08 in the BP, and steeply rose to 1.57 +/- 0.19 at the distal part of the BP. The RBE distribution for the DS SOBP beam was approximately 0.96 +/- 0.16 to 1.01 +/- 0.16 at shallow depths, and 1.01 +/- 0.16 to 1.28 +/- 0.17 within the SOBP. The RBE significantly increased from 1.29 +/- 0.17 to 1.43 +/- 0.18 at the distal edge of the SOBP. Conclusions: The SOI microdosimeter with its well-defined 3D SV has applicability in characterizing proton radiation fields and can measure relevant physical parameters to model the RBE with submillimeter spatial resolution. It has been shown that for a physical dose of 1.82Gy at the BP, the derived RBE based on the MKM model increased from 1.14 to 1.6 in the BP and its distal part. Good agreement was observed between the experimental and simulation results, confirming the potential application of SOI microdosimeter with 3D SV for quality assurance in proton therapy. (C) 2017 American Association of Physicists in Medicine
引用
收藏
页码:6085 / 6095
页数:11
相关论文
共 50 条
  • [41] Using patient-specific bolus for pencil beam scanning proton treatment of periorbital disease
    Kang, Minglei
    Hasan, Shaakir
    Press, Robert H.
    Yu, Francis
    Abdo, Mashal
    Xiong, Weijun
    Choi, Jehee I.
    Simone, Charles B., II
    Lin, Haibo
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (01): : 203 - 209
  • [42] Reirradiation for Rectal Cancer Using Pencil Beam Scanning Proton Therapy: A Single Institutional Experience
    Koroulakis, Antony
    Molitoris, Jason
    Kaiser, Adeel
    Hanna, Nader
    Bafford, Andrea
    Jiang, Yixing
    Bentzen, Soren
    Regine, William F.
    ADVANCES IN RADIATION ONCOLOGY, 2021, 6 (01)
  • [43] Experimental characterization of two-dimensional spot profiles for two proton pencil beam scanning nozzles
    Lin, Liyong
    Ainsley, Christopher G.
    Solberg, Timothy D.
    McDonough, James E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (02): : 493 - 504
  • [44] Experimental and Monte Carlo characterization of a dynamic collimation system prototype for pencil beam scanning proton therapy
    Smith, Blake R.
    Pankuch, Mark
    Hyer, Daniel E.
    Culberson, Wesley S.
    MEDICAL PHYSICS, 2020, 47 (10) : 5343 - 5356
  • [45] Parametric characterization of penumbra reduction for aperture-collimated pencil beam scanning (PBS) proton therapy
    Maes, Dominic
    Regmi, Rajesh
    Taddei, Phillip
    Bloch, Charles
    Bowen, Steven
    Nevitt, Alexander
    Leuro, Erick
    Wong, Tony
    Rosenfeld, Anatoly
    Saini, Jatinder
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (03):
  • [46] Characterization of penumbra sharpening and scattering by adaptive aperture for a compact pencil beam scanning proton therapy system
    Grewal, Hardev S.
    Ahmad, Salahuddin
    Jin, Hosang
    MEDICAL PHYSICS, 2021, 48 (04) : 1508 - 1519
  • [47] Validation of High-Resolution 3D Patient QA for Proton Pencil Beam Scanning and IMPT by Polymer Gel Dosimetry
    Cardin, A.
    Avery, S.
    Maryanski, M.
    Ding, X.
    Kassaee, A.
    Lin, L.
    MEDICAL PHYSICS, 2014, 41 (06) : 384 - 384
  • [48] Design of a combined X-Y scanning magnet with high field uniformity for pencil beam scanning proton therapy
    Yang, Ziyi
    Yang, Jun
    Liu, Xu
    Liao, Yicheng
    Qin, Bin
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1067
  • [49] When Does Pencil Beam Scanning Become Superior to Passive Scattered Proton Therapy for Pediatric Head and Neck Cancers?
    Moteabbed, M.
    Depauw, N.
    Kooy, H.
    Yock, T.
    Paganetti, H.
    MEDICAL PHYSICS, 2015, 42 (06) : 3528 - 3528
  • [50] Evaluating the Dose Accuracy of a 2D Ion Chamber Array in High Dose Rate Pencil Beam Scanning Proton Beam
    Perles, L.
    Mascia, A.
    Piskulich, F.
    Lepage, R.
    Zhang, Y.
    Giebeler, A.
    Dong, L.
    MEDICAL PHYSICS, 2014, 41 (06)