Characterization of proton pencil beam scanning and passive beam using a high spatial resolution solid-state microdosimeter

被引:56
|
作者
Tran, Linh T. [1 ]
Chartier, Lachlan [1 ]
Bolst, David [1 ]
Pogossov, Alex [1 ]
Guatelli, Susanna [1 ]
Petasecca, Marco [1 ]
Lerch, Michael L. F. [1 ]
Prokopovich, Dale A. [2 ]
Reinhard, Mark I. [2 ]
Clasie, Benjamin [3 ]
Depauw, Nicolas [3 ]
Kooy, Hanne [3 ]
Flanz, Jacob B. [3 ]
McNamara, Aimee [3 ]
Paganetti, Harald [3 ]
Beltran, Chris [4 ]
Furutani, Keith [4 ]
Perevertaylo, Vladimir L. [5 ]
Jackson, Michael [6 ]
Rosenfeld, Anatoly B. [1 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[2] Australian Nucl Sci & Technol Org, Lucas Heights, Australia
[3] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[4] Mayo Clin, Radiat Oncol, Rochester, MN USA
[5] SPA BIT, Kiev, Ukraine
[6] Prince Wales Hosp, Dept Radiat Oncol, Randwick, NSW 2031, Australia
基金
澳大利亚研究理事会;
关键词
3D sensitive volume; microdosimetry; pencil beam scanning (PBS); proton therapy; RBE; silicon on insulator (SOI); RELATIVE BIOLOGICAL EFFECTIVENESS; RADIATION-FIELDS; CELL-SURVIVAL; C-12; ION; RBE; SILICON; MODEL;
D O I
10.1002/mp.12563
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This work aims to characterize a proton pencil beam scanning (PBS) and passive double scattering (DS) systems as well as to measure parameters relevant to the relative biological effectiveness (RBE) of the beam using a silicon on insulator (SOI) microdosimeter with well-defined 3D sensitive volumes (SV). The dose equivalent downstream and laterally outside of a clinical PBS treatment field was assessed and compared to that of a DS beam. Methods: A novel silicon microdosimeter with well-defined 3D SVs was used in this study. It was connected to low noise electronics, allowing for detection of lineal energies as low as 0.15keV/m. The microdosimeter was placed at various depths in a water phantom along the central axis of the proton beam, and at the distal part of the spread-out Bragg peak (SOBP) in 0.5mm increments. The RBE values of the pristine Bragg peak (BP) and SOBP were derived using the measured microdosimetric lineal energy spectra as inputs to the modified microdosimetric kinetic model (MKM). Geant4 simulations were performed in order to verify the calculated depth-dose distribution from the treatment planning system (TPS) and to compare the simulated dose-mean lineal energy to the experimental results. Results: For a 131MeV PBS spot (124.6mm R-90 range in water), the measured dose-mean lineal energy (y(D)) over bar increased from 2 keV/mu m at the entrance to 8keV/m in the BP, with a maximum value of 10 keV/mu m at the distal edge. The derived RBE distribution for the PBS beam slowly increased from 0.970.14 at the entrance to 1.04 +/- 0.09 proximal to the BP, then to 1.1 +/- 0.08 in the BP, and steeply rose to 1.57 +/- 0.19 at the distal part of the BP. The RBE distribution for the DS SOBP beam was approximately 0.96 +/- 0.16 to 1.01 +/- 0.16 at shallow depths, and 1.01 +/- 0.16 to 1.28 +/- 0.17 within the SOBP. The RBE significantly increased from 1.29 +/- 0.17 to 1.43 +/- 0.18 at the distal edge of the SOBP. Conclusions: The SOI microdosimeter with its well-defined 3D SV has applicability in characterizing proton radiation fields and can measure relevant physical parameters to model the RBE with submillimeter spatial resolution. It has been shown that for a physical dose of 1.82Gy at the BP, the derived RBE based on the MKM model increased from 1.14 to 1.6 in the BP and its distal part. Good agreement was observed between the experimental and simulation results, confirming the potential application of SOI microdosimeter with 3D SV for quality assurance in proton therapy. (C) 2017 American Association of Physicists in Medicine
引用
收藏
页码:6085 / 6095
页数:11
相关论文
共 50 条
  • [31] RADIATION THERAPY WITH HIGH-ENERGY ELECTRONS USING PENCIL BEAM SCANNING
    CARPENDER, JW
    LANZL, LH
    GRIEM, ML
    SKAGGS, LS
    AMERICAN JOURNAL OF ROENTGENOLOGY RADIUM THERAPY AND NUCLEAR MEDICINE, 1963, 90 (02): : 221 - +
  • [32] Solid-state VCSEL beam scanner with ultra-large field of view and high resolution
    Li, Ruixiao
    Ho, Zeuku
    Gu, Xiaodong
    Shinada, Satoshi
    Koyama, Fumio
    2021 OPTICAL FIBER COMMUNICATIONS CONFERENCE AND EXPOSITION (OFC), 2021,
  • [33] Characterization of a high-resolution 2D transmission ion chamber for independent validation of proton pencil beam scanning of conventional and FLASH dose delivery
    Zou, Wei
    Diffenderfer, Eric S.
    Ota, Kan
    Boisseau, Paul
    Kim, Michele M.
    Cai, Yongliang
    Avery, Stephen M.
    Carlson, David J.
    Wiersma, Rodney D.
    Lin, Alexander
    Koumenis, Constantinos
    Cengel, Keith A.
    Metz, James M.
    Dong, Lei
    Teo, Boonkeng K.
    MEDICAL PHYSICS, 2021, 48 (07) : 3948 - 3957
  • [34] The dosimetric enhancement of GRID profiles using an external collimator in pencil beam scanning proton therapy
    Smith, Blake R.
    Nelson, Nicholas P.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Hill, Patrick M.
    Yu, Jen
    Gutierrez, Alonso N.
    Allen, Bryan G.
    Hyer, Daniel E.
    MEDICAL PHYSICS, 2022, 49 (04) : 2684 - 2698
  • [35] Proton Radiography Using Pencil Beam Scanning and a Novel, Low- Cost Range Telescope
    Dolney, D.
    Mayers, G.
    Newcomer, M.
    Weiss, D.
    Meekins, E.
    Bollinger, D.
    Desai, N.
    Maughan, R.
    Solberg, T.
    Hollebeek, R.
    MEDICAL PHYSICS, 2016, 43 (06) : 3324 - 3325
  • [36] Multicriteria Optimization Algorithm for Intensity Modulated Radiation Therapy Using Pencil Proton Beam Scanning
    Beltran, C.
    Kamal, H.
    MEDICAL PHYSICS, 2016, 43 (06) : 3510 - 3510
  • [37] Optimization of GEANT4 settings for Proton Pencil Beam Scanning simulations using GATE
    Grevillot, Loic
    Frisson, Thibault
    Zahra, Nabil
    Bertrand, Damien
    Stichelbaut, Frederic
    Freud, Nicolas
    Sarrut, David
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (20): : 3295 - 3305
  • [38] Validation and Implementation of Proton Pencil Beam Scanning Nozzle Using TOPAS Monte Carlo Simulation
    Lin, C.
    Feng, Y.
    MEDICAL PHYSICS, 2020, 47 (06) : E875 - E875
  • [39] Proton range assessment using prompt gamma monitoring of realistic pencil beam scanning treatments
    Janssens, G.
    Smeets, J.
    Stappen, F. Vander
    Prieels, D.
    Perali, I.
    Clementel, E.
    Hotoiu, L.
    Sterpin, E.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S180 - S181
  • [40] Dosimetric Impacts of Couch Moving Rails On Proton Treatment Using Pencil-Beam Scanning
    Zhang, Y.
    Park, J.
    Blalock, J.
    Stevens, R.
    Johnson, P.
    MEDICAL PHYSICS, 2022, 49 (06) : E880 - E881