Attenuation Correction Methods Suitable for Brain Imaging with a PET/MRI Scanner: A Comparison of Tissue Atlas and Template Attenuation Map Approaches

被引:70
|
作者
Malone, Ian B. [1 ]
Ansorge, Richard E. [1 ]
Williams, Guy B. [2 ]
Nestor, Peter J. [3 ]
Carpenter, T. Adrian [2 ]
Fryer, Tim D. [2 ]
机构
[1] Univ Cambridge, Cavendish Lab, Cambridge CB3 0HE, England
[2] Univ Cambridge, Addenbrookes Hosp, Dept Clin Neurosci, Wolfson Brain Imaging Ctr, Cambridge CB3 0HE, England
[3] Univ Cambridge, Addenbrookes Hosp, Dept Clin Neurosci, Neurol Unit, Cambridge CB3 0HE, England
基金
英国工程与自然科学研究理事会; 英国医学研究理事会;
关键词
attenuation correction; brain; nonrigid registration; PET/MRI scanner; CEREBRAL 3D PET; IMAGES;
D O I
10.2967/jnumed.110.085076
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Modeled attenuation correction (AC) will be necessary for combined PET/MRI scanners not equipped with transmission scanning hardware. We compared 2 modeled AC approaches that use nonrigid registration with rotating Ge-68 rod-based measured AC for 10 subjects scanned with F-18-FDG. Methods: Two MRI and attenuation map pairs were evaluated: tissue atlas-based and measured templates. The tissue atlas approach used a composite of the BrainWeb and Zubal digital phantoms, whereas the measured templates were produced by averaging spatially normalized measured MR image and coregistered attenuation maps. The composite digital phantom was manually edited to include 2 additional tissue classes (paranasal sinuses, and ethmoidal air cells or nasal cavity). In addition, 3 attenuation values for bone were compared. The MRI and attenuation map pairs were used to generate subject-specific attenuation maps via nonrigid registration of the MRI to the MR image of the subject. SPM2 and a B-spline free-form deformation algorithm were used for the nonrigid registration. To determine the accuracy of the modeled AC approaches, radioactivity concentration was assessed on a voxelwise and regional basis. Results: The template approach produced better spatial consistency than the phantom-based atlas, with an average percentage error in radioactivity concentration across the regions, compared with measured AC, of -1.2% +/- 1.2% and 1.5% +/- 1.9% for B-spline and SPM2 registration, respectively. In comparison, the tissue atlas method with B-spline registration produced average percentage errors of 0.0% +/- 3.0%, 0.9% +/- 2.9%, and 2.9% +/- 2.8% for bone attenuation values of 0.143 cm(-1), 0.152 cm(-1), and 0.172 cm(-1), respectively. The largest errors for the template AC method were found in parts of the frontal cortex (-3%) and the cerebellar vermis (-5%). Intersubject variability was higher with SPM2 than with B-spline. Compared with measured AC, template AC with B-spline and SPM2 achieved a correlation coefficient (R-2) of 0.99 and 0.98, respectively, for regional radioactivity concentration. The corresponding R-2 for the tissue atlas approach with B-spline registration was 0.98, irrespective of the bone attenuation coefficient. Conclusion: Nonrigid registration of joint MRI and attenuation map templates can produce accurate AC for brain PET scans, particularly with measured templates and B-spline registration. Consequently, these methods are suitable for AC of brain scans acquired on combined PET/MRI systems.
引用
收藏
页码:1142 / 1149
页数:8
相关论文
共 50 条
  • [1] Comparison of MR Based Attenuation Correction Methods with CT Based Attenuation Correction in Dynamic Brain PET imaging
    Firouzian, A.
    Delso, G.
    Hallett, W.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S695 - S696
  • [2] Comparison of different methods for attenuation correction in brain PET
    Mirzaei, S
    Knoll, P
    Köhn, H
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2000, 39 (06): : N95 - N95
  • [3] An Investigation of Attenuation Correction with Attenuation Map Library in PET Imaging
    Wan, Lu
    Zhang, Yongxue
    Cao, Xiaoqing
    Zeng, Shaoqun
    Xie, Qingguo
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3791 - 3793
  • [4] Attenuation correction for the NIH ATLAS small animal PET scanner
    Yao, RT
    Seidel, J
    Liow, JS
    Green, MV
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (03) : 664 - 668
  • [5] Attenuation correction for the NIH ATLAS small animal PET scanner
    Yao, RT
    Seidel, R
    Liow, JS
    Green, MV
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2283 - 2287
  • [6] Does deep learning approaches outperform atlas-guided attenuation correction in brain PET/MRI?
    Arabi, Hossein
    Zeng, Guodong
    Zheng, Guoyan
    Zaidi, Habib
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [7] MR-based attenuation correction for cardiac FDG PET on a hybrid PET/MRI scanner: comparison with standard CT attenuation correction
    Jan Vontobel
    Riccardo Liga
    Mathias Possner
    Olivier F. Clerc
    Fran Mikulicic
    Patrick Veit-Haibach
    Edwin E. G. W. ter Voert
    Tobias A. Fuchs
    Julia Stehli
    Aju P. Pazhenkottil
    Dominik C. Benz
    Christoph Gräni
    Oliver Gaemperli
    Bernhard Herzog
    Ronny R. Buechel
    Philipp A. Kaufmann
    European Journal of Nuclear Medicine and Molecular Imaging, 2015, 42 : 1574 - 1580
  • [8] MR-based attenuation correction for cardiac FDG PET on a hybrid PET/MRI scanner: comparison with standard CT attenuation correction
    Vontobel, Jan
    Liga, Riccardo
    Possner, Mathias
    Clerc, Olivier F.
    Mikulicic, Fran
    Veit-Haibach, Patrick
    ter Voert, Edwin E. G. W.
    Fuchs, Tobias A.
    Stehli, Julia
    Pazhenkottil, Aju P.
    Benz, Dominik C.
    Graeni, Christoph
    Gaemperli, Oliver
    Herzog, Bernhard
    Buechel, Ronny R.
    Kaufmann, Philipp A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (10) : 1574 - 1580
  • [9] Comparison of attenuation collection methods in brain PET/MRI study
    Ishii, Shirou
    Nanbu, Takeyuki
    Sugawara, Shigeyasu
    Suenaga, Hiroki
    Kuroiwa, Daichi
    Sekino, Hirofumi
    Miyajima, Masayuki
    Kubo, Hitoshi
    Oriuchi, Noboru
    Ito, Hiroshi
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [10] MRI for attenuation correction in PET: methods and challenges
    Wagenknecht, Gudrun
    Kaiser, Hans-Juergen
    Mottaghy, Felix M.
    Herzog, Hans
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2013, 26 (01): : 99 - 113