Attenuation Correction Methods Suitable for Brain Imaging with a PET/MRI Scanner: A Comparison of Tissue Atlas and Template Attenuation Map Approaches

被引:70
|
作者
Malone, Ian B. [1 ]
Ansorge, Richard E. [1 ]
Williams, Guy B. [2 ]
Nestor, Peter J. [3 ]
Carpenter, T. Adrian [2 ]
Fryer, Tim D. [2 ]
机构
[1] Univ Cambridge, Cavendish Lab, Cambridge CB3 0HE, England
[2] Univ Cambridge, Addenbrookes Hosp, Dept Clin Neurosci, Wolfson Brain Imaging Ctr, Cambridge CB3 0HE, England
[3] Univ Cambridge, Addenbrookes Hosp, Dept Clin Neurosci, Neurol Unit, Cambridge CB3 0HE, England
基金
英国工程与自然科学研究理事会; 英国医学研究理事会;
关键词
attenuation correction; brain; nonrigid registration; PET/MRI scanner; CEREBRAL 3D PET; IMAGES;
D O I
10.2967/jnumed.110.085076
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Modeled attenuation correction (AC) will be necessary for combined PET/MRI scanners not equipped with transmission scanning hardware. We compared 2 modeled AC approaches that use nonrigid registration with rotating Ge-68 rod-based measured AC for 10 subjects scanned with F-18-FDG. Methods: Two MRI and attenuation map pairs were evaluated: tissue atlas-based and measured templates. The tissue atlas approach used a composite of the BrainWeb and Zubal digital phantoms, whereas the measured templates were produced by averaging spatially normalized measured MR image and coregistered attenuation maps. The composite digital phantom was manually edited to include 2 additional tissue classes (paranasal sinuses, and ethmoidal air cells or nasal cavity). In addition, 3 attenuation values for bone were compared. The MRI and attenuation map pairs were used to generate subject-specific attenuation maps via nonrigid registration of the MRI to the MR image of the subject. SPM2 and a B-spline free-form deformation algorithm were used for the nonrigid registration. To determine the accuracy of the modeled AC approaches, radioactivity concentration was assessed on a voxelwise and regional basis. Results: The template approach produced better spatial consistency than the phantom-based atlas, with an average percentage error in radioactivity concentration across the regions, compared with measured AC, of -1.2% +/- 1.2% and 1.5% +/- 1.9% for B-spline and SPM2 registration, respectively. In comparison, the tissue atlas method with B-spline registration produced average percentage errors of 0.0% +/- 3.0%, 0.9% +/- 2.9%, and 2.9% +/- 2.8% for bone attenuation values of 0.143 cm(-1), 0.152 cm(-1), and 0.172 cm(-1), respectively. The largest errors for the template AC method were found in parts of the frontal cortex (-3%) and the cerebellar vermis (-5%). Intersubject variability was higher with SPM2 than with B-spline. Compared with measured AC, template AC with B-spline and SPM2 achieved a correlation coefficient (R-2) of 0.99 and 0.98, respectively, for regional radioactivity concentration. The corresponding R-2 for the tissue atlas approach with B-spline registration was 0.98, irrespective of the bone attenuation coefficient. Conclusion: Nonrigid registration of joint MRI and attenuation map templates can produce accurate AC for brain PET scans, particularly with measured templates and B-spline registration. Consequently, these methods are suitable for AC of brain scans acquired on combined PET/MRI systems.
引用
收藏
页码:1142 / 1149
页数:8
相关论文
共 50 条
  • [41] Comparison of attenuation correction methods for brain SPECT images
    Jo, Jinu
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [42] Comparison of ZTE and atlas attenuation correction for brain [15O]H2O-PET/MR imaging
    Hjornevik, T.
    Fan, A. P.
    Khalighi, M.
    Gandhi, H.
    Holley, D.
    Gulaka, P. K.
    Shen, B.
    Park, J. H.
    Chin, F. T.
    Zaharchuk, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S501 - S502
  • [43] Evaluation of zero-echo-time attenuation correction for integrated PET/MR brain imaging-comparison to head atlas and 68Ge-transmission-based attenuation correction
    Sousa, Joao M.
    Appel, Lieuwe
    Engstrom, Mathias
    Papadimitriou, Stergios
    Nyholm, Dag
    Larsson, Elna-Marie
    Ahlstrom, Hakan
    Lubberink, Mark
    EJNMMI PHYSICS, 2018, 5
  • [44] Bone attenuation in brain-PET/MR imaging should be accounted for during attenuation correction and PET reconstruction
    Andersen, F. L.
    Keller, S. H.
    Hansen, A. E.
    Beyer, T.
    Law, I.
    Hojgaard, L.
    Holm, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S174 - S174
  • [45] Zero Echo Time MR Attenuation Correction Method on the GE SIGNA PET/MR: Comparison with CT Based Attenuation Correction in Dynamic PET Brain imaging
    Firouzian, A.
    Delso, G.
    McCutcheon, R.
    Nour, M.
    Howes, O.
    Hallett, W.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S288 - S289
  • [46] Validation of PET/MRI attenuation correction methodology in the study of brain tumours
    Francesca De Luca
    Martin Bolin
    Lennart Blomqvist
    Cecilia Wassberg
    Heather Martin
    Anna Falk Delgado
    BMC Medical Imaging, 20
  • [47] MRI-aided Attenuation Correction for PET Imaging with Deep Learning
    Lei, Yang
    Dong, Xue
    Wang, Tonghe
    Higgins, Kristin
    Liu, Tian
    Curran, Walter J.
    Nye, Jonathan A.
    Mao, Hui
    Yang, Xiaofeng
    MEDICAL IMAGING 2020: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11317
  • [48] Validation of PET/MRI attenuation correction methodology in the study of brain tumours
    De Luca, Francesca
    Bolin, Martin
    Blomqvist, Lennart
    Wassberg, Cecilia
    Martin, Heather
    Delgado, Anna Falk
    BMC MEDICAL IMAGING, 2020, 20 (01)
  • [49] Accuracy of a new atlas-based attenuation correction method in comparison to standard MR-based attenuation correction of the skull region in PET/MR imaging
    Rausch, I.
    Rischka, L.
    Ladefoged, C. N.
    Fenchel, M.
    Hahn, A.
    Lanzenberger, R.
    Traub-Weidinger, T.
    Beyer, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S78 - S78
  • [50] A hybrid method for generation of attenuation map for MR-based attenuation correction of PET data in prostate PET/MR imaging
    Mehdi Shirin Shandiz
    Mohammad Hadi Arabi
    Pardis Ghafarian
    Mehrdad Bakhshayesh Karam
    Hamidreza Saligheh Rad
    Mohammad Reza Ay
    EJNMMI Physics, 1 (Suppl 1)